Bose FreeSpace E4 Series II- User Manual

Bose FreeSpace E4 Series II

Bose FreeSpace E4 Series II– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
Page: / 4

Table of Contents:

  • Page 2 – Installer; Fuse; SENSE MICROPHONES –; Installe; WALL PLATE CONNECTION –; FreeSpace; English
  • Page 3 – Guide de démarrage du système FreeSpace; Français
  • Page 4 – Coffret à fusible avec indicateur de tension électrique; La configuration du coffret à fusible; Fiche du cordon d'alimentation électrique –; Fusible; Guide de référence rapide du système FreeSpace
Loading the manual

AMP OUT

AUX OUT/
CONTR

OL

DIRECT IN

/

CONTR

OL

SENSE MICR

OPHONES

1

2

3

4

WALL PLA TE CONNECTION

CONTACT
CLOSURE

INPUT

LINE

2

MUSIC ON

HOLD/

PBX OUT

Bose Corporation, Framingham , MA 01701-9168

Made in the U.S.A.

70V

100V

RS232

MIC/

LINE

3

MIC/PAGE/

LINE4

1

3

2

4

INPUTS

RISQUE DE CHOC ELECTRIQUE

NE P AS OUVRIR

RISK OF ELECTRICA

L

SHOCK

DO NOT OPEN

POWER

ON

OFF

OUTPUT

VOL TAGE

3

4

1

2

DO NOT SWITCH

WHILE POWER IS ON

OUTPUTS

LINE

1

AUDIO SOURCES

400 Watt System Electronics

CLASS 2 WIRING

AMP OUT

100/120V~AC T6.25A, L250V
220/240V~AC T3.15A, L250V

50/60Hz

300W MAX

T

üV Rheinland

geprüfte
Sicherhei

t

AUDIO

EQUIPMENT

LISTED 917D

®

PTT

PTT

12V

This device complies

with part 15 of the FCC rules. Operation is

subject to the following conditions

:

(1)This device may not cause

harmful interference and (2)this device must accept any interference
received,inc

luding

interference which may cause undesired operat

ion.

Complies with Canadian ICES-003 Class

A

Spec.

RS232

FreeSpace E4 Series II

• Connect a straight-wired DB9M-to-DB9F cable between

the COM port of your PC and the RS-232 port of the
E4 system.

• Make sure the E4 system POWER switch is set to ON.

• Launch the

Installer

software on your PC.

NOTE:

The software installation disc is included with

the E4 system hardware.

• When the connection is initialized, the

Installer

software

automatically switches the E4 unit from standby to
operating mode.

• Once the connection is established, the Hardware Set

Up window for the E4 system appears on the screen.

• Select

Out Gain

for each zone.

• Click the

Mute

checkbox to silence the zone outputs of

the E4 system.

• Leave one zone active for monitoring purposes, or

connect a single speaker to the ZONE 1 output.

• Select

ZONE Set Up

for each zone output.

• Select the proper loudspeaker EQ type from the

Speaker EQ

drop list.

O p t i - s o u r c e

O p t i - s o u r c e

• Select

In Gain

for the first music source.

• Select the proper input type from the

Type

drop list.

• When using sources that have an output gain control,

increase the source output gain until the signal meter is
solid green. Occasional flashing red is normal.

• When using sources that do not have an output gain

control, increase the input gain using the

Gain

slider

until the signal meter is solid green.

• Set

Opti-source

®

to

On

. If you hear a dramatic

increase or decrease in volume, adjust your input gain
accordingly.

NOTE:

For detailed information on the setup of mic, line

and page sources see the online help system.

1

Connect your PC to the E4 system

2

Start the

Installer

software

3

Mute the zone outputs

4

Set zone Speaker EQ

5

Set Input Gain for music sources

O p t i - s o u r c e

• Select

Source Assign

for each zone.

• Move selected System Sources to the ZONE Sources

list using the right arrow button.

• In the Zone Sources list, double click on the name of

the source you want as the default source.

• Assign Paging to a zone by adding the PAGE source.
• Make sure all zones are connected to the E4 system.

• Select

Out Gain

for each zone.

• Raise the

Gain

slider to the desired maximum volume

and move the Maximum Gain Stop to this location.

• Lower the

Gain

slider to the desired minimum volume

and move the Minimum Gain Stop to this location.

• Set the

Gain

slider to the desired initial volume.

• Select

EQ

for each zone.

• Make the desired adjustments to the Low, Mid and Hi

equalizer controls.

• Select

Dynamic EQ

for the zone and set it to

On

.

• Check that the Auto Volume sensing microphone has

been installed according to recommendations.

• Select

Auto Volume

for the zone to be calibrated.

• Set the

Auto Volume Tracking

level. Use a level of

“less than” by “3” or “6” dB for background systems,
and a level of “equal to” or “more than” by “1” or “3” dB
for foreground systems.

• Click the

Set Up

button to start the calibration process.

• Follow the onscreen instructions during the process.
• For detailed information on the Auto Volume function,

see the online help system.

• Click the

Flash Hardware Configuration

button to

save the current system settings as the new default
configuration. The default configuration contains the
settings that are loaded when the E4 system is powered
on.

• Click the

Save File

button to save the settings in a file

on your PC where they can be stored for future use.

10

Flash hardware configuration

7

Set zone Output Gain

6

Assign sources to zones

8

Adjust the zone EQ

9

Calibrate Auto Volume

©2004 Bose Corporation, The Mountain, Framingham, MA 01701-9168 USA

279146 AM Rev.00 CCM-000922

NOTE:

Install your FreeSpace

®

system Installer™

software before following these steps.

FreeSpace

®

E4 Series II System Quick Start-Up Guide

English

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Installer; Fuse; SENSE MICROPHONES –; Installe; WALL PLATE CONNECTION –; FreeSpace; English

Signal out options 7. ZONE 4 LINE OUT – A line-level output that duplicates the program mate- rial from LINE 4. May be used to feed another amplifier installed for a largezone. Use the 12V control output to connect to Bose ® amplifier sequence inputs. 8. MUSIC ON HOLD/PBX OUT – Connect to Music on H...

Page 3 - Guide de démarrage du système FreeSpace; Français

AMP OUT AUX OUT/CONTR OL DIRECT IN / CONTR OL SENSE MICR OPHONES 1 2 3 4 WALL PLA TE CONNECTION CONTACTCLOSURE INPUT LINE 2 MUSIC ON HOLD/ PBX OUT Bose Corporation, Framingham , MA 01701-9168 Made in the U.S.A. 70V 100V RS232 MIC/ LINE 3 MIC/PAGE/ LINE4 1 3 2 4 INPUTS RISQUE DE CHOC ELECTRIQUE NE P ...

Page 4 - Coffret à fusible avec indicateur de tension électrique; La configuration du coffret à fusible; Fiche du cordon d'alimentation électrique –; Fusible; Guide de référence rapide du système FreeSpace

Options de sortie ligne 7. ZONE 4 LINE OUT (sortie ligne zone 4) – Sortie de niveau ligne reproduisant le signal provenant du connecteur AMP OUT 4 (sortie ampli 4).Permet d'alimenter un autre amplificateur installé pour une grande zone.Utilisez la sortie de commande 12 V afin de vous connecter aux e...