Bosch DS161 - Installation Manual

Bosch DS161

Bosch DS161 Sensor – Installation Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
Page: / 8

Table of Contents:

  • Page 2 – DOOR; Optional Trimplate; Table 1; T T; Section 3.3 Wiring Examples; Contact Output Wiring; Section 4.3 Relay Mode; Examples
  • Page 4 – Figure 14: Sequential Logic Input Configuration; For DIP switch settings, refer to; Figure 15: Door Monitor Contacts Configuration (First Option); For DIP switch settings, refer to; Figure 16: Door Monitor Contacts Configuration (Second Option)
  • Page 5 – Settings; ON
  • Page 6 – Table 3; Complete the Installation; Secure by tightening the; tate; Rotate the barrel to the; To adjust the volume, turn the Volume Control with a screwdriver.; Patterns
  • Page 7 – Figure 23: Coverage Pattern Example 2; Figure 24: Masking Options; Figure 25: Insert a Masking Wedge; Figure 26: Remove a Masking Wedge; Masking
  • Page 8 – Notes
Loading the manual
Page 1

DS160/DS161 Installation Guide

High Performance Request-to-Exit Sensors

1.0 Description

The DS160/161 is a passive-infrared (PIR) detector designed for Request
to Exit (REX) interior applications.

The DS160/161 is UL Listed as an access control device under the UL
294 Standard and is listed for Class I for UL Canada under ULC-S319
when it is connected to a UL approved access control system. For C-UL
listed installation applications, the REX detector shall be connected to
ULC-S319 listed compatible devices (i.e. control units, power supply and
locks).

The technology designed into the DS160/161 is based on the principal
that all objects emit infrared energy. The warmer an object is, the more
infrared energy emitted. Its PIR technology allows the DS160/161 to
detect the change in infrared energy that occurs when a person passes
through its field of view.

The DS160/161 has features such as Sequential Logic Input (SLI) to
eliminate unauthorized entry. SLI allows you to arm the detector using any
dry contact device, such as a second detector, card reader, or the access
control system. This provides better control for this type of application.

A built-in sounder can be automatically activated if the door is propped
open. The sounder can be controlled from any dry contact device. The
DS160/161 detection pattern provides dense C-shaped coverage ideal for
most REX applications. In addition, complete pattern control allows it to be
adjusted to a single zone or placed over a doorknob, for example. There
are fifteen possible coverage patterns to accommodate most applications.
This, combined with the ability to monitor the door and intelligently control
the lock, adds considerable security to these types of applications.

The DS160/161 uses Motion Analyzer II signal processing to help prevent
false activation due to environmental conditions. The relay output consists
of two Form “C” contacts that can be adjusted to latch from approximately
0.5 to 64 sec. The latch time features two modes of operation, resettable
(where the relay timer will not time out as long as someone is in the field
of view) and non-resettable (where the relay will remain latched for a fixed
period of time). The relay can also be programmed to fail safe or fail
secure in the event of power loss.

The DS160/161 provides one set of relay contacts specially protected
from EMF (voltage) spikes caused by connecting to inductive loads.

The DS160/161 may either be ceiling or wall mounted, and its pattern may
be aimed and/or masked for more effective use based upon installation
needs. It is not designed as a primary means of exit for emergency egress
applications.

The DS160/161 is available in a light grey (DS160) or a black (DS161)
enclosure along with an optional trim plate (light gray TP160 or black
TP161) that can cover a single gang box. Panic hardware must be used
with this or any other egress device.

Figure 1: Detector Component Locations

Wire

Terminals

Sounder

Sounder Volume Control

DIP Switches

Tamper Switch

LED

Lens

Lock-Down Screw

O

N

1
2
3
4
5
6
7
8
9
10

2.0 Installation

1.

Remove the cover using a small flat blade screwdriver.

Figure 2: Cover Removal

Insert screwdriver

here

Bottom

of

unit

2.

Rotate the detector clockwise to remove it from the base.

Figure 3: Detector Removal

Ro

tate

3.

Select a mounting location.

Figure 4: Mounting Locations

Push to Exit

Alarm will Sound

Push to Exit

Alarm will Sound

Push to Exit

Alarm will Sound

Push to Exit

Alarm will Sound

Above the

Door

On the Ceiling

Above

Double Doors

Before you mount the unit, review

Section 6.0 Coverage

Patterns

on page 6 for more information on the placement

and location of the DS160/161.

4.

Route the wiring through the base before mounting the base to the
wall or ceiling. Refer to

Step 5

on page 2 when using the optional

trim plate (TP160 or TP161).

Figure 5: Wire Routing

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Was this manual helpful?

About this manual

Brand
Bosch
Model
DS161
Document type
Installation Manual
Category
Sensor
Language(s)
English
Pages
8
Format
PDF

Summary

Page 2 - DOOR; Optional Trimplate; Table 1; T T; Section 3.3 Wiring Examples; Contact Output Wiring; Section 4.3 Relay Mode; Examples

2 | F01U252567-01 | 9/11 DS160/DS161 Installation Guide © 2011 Bosch Security Systems, Inc. 5. When using the optional trim plate (TP160 or TP161), run the wiring through the trim plate and into the base before mounting the base and trim plate onto a single gang electrical box. Figure 6: Optional Tr...

Page 4 - Figure 14: Sequential Logic Input Configuration; For DIP switch settings, refer to; Figure 15: Door Monitor Contacts Configuration (First Option); For DIP switch settings, refer to; Figure 16: Door Monitor Contacts Configuration (Second Option)

4 | F01U252567-01 | 9/11 DS160/DS161 Installation Guide © 2011 Bosch Security Systems, Inc. 3.3.5 Sequential Logic Input The detector only activates by motion when the Sequential Logic Input (Terminal R) is open, or for 10 sec after it closes. For example, when a second detector placed before the DS...

Page 5 - Settings; ON

© 2011 Bosch Security Systems, Inc. DS160/DS161 Installation Guide 9/11 | F01U252567-01 | 5 3.3.8 Disabling the Request-to-Exit The DS160/161 can be disabled by using Terminal R and an external device such as an access control or burglar alarm system. When the contact connected to Terminal R closes,...

Ask a question

Up to 3 photos. Max 5 MB each. Formats: JPG, JPEG, PNG, WebP.