M3LDY
EM-2664 Rev.2
P. 1 / 6
BEFORE USE ....
Thank you for choosing M-System. Before use, check the
package you received as below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■
PACKAGE INCLUDES:
Signal conditioner ....................................................... (1)
I/O range and tag name label sheet ........................... (1)
■
MODEL NO.
Check that the model No. described on the specification label
is exactly what you ordered.
■
INSTRUCTION MANUAL
This manual describes the necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
The M3LDY with Option /A is programmable using the PC
configurator software. For detailed information on the PC
configuration, refer to the M3CON instruction manual. The
M3CON PC Configurator Software is downloadable at M-
System’s web site: http://www.m-system.co.jp.
POINTS OF CAUTION
■
CONFORMITY WITH UL
(UL is unavailable for certain model suffix options.)
• This equipment is suitable for use in a Pollution Degree 2
environment.
• This equipment is to be used with the maximum operating
voltage 30Vrms and 42.4Vpeak or 60V DC.
• The equipment must be mounted inside a suitable fire
enclosure.
• Operating temperature: -25 to +55
°
C (-13 to +131
°
F)
■
POWER INPUT RATING & OPERATIONAL RANGE
• Check the power rating for the unit on the specification
label.
Rating 24V DC: 24V
±
10%, approx. 3W
• Power fuse: A power fuse of the rating as shown below is
incorporated for safety. However, DO NOT replace it by the
user.
T 0.25A 125V
■
SAFETY PRECAUTION
• Before you remove the unit or mount it, turn off the power
supply and input signal for safety.
■
ENVIRONMENT
• Indoor use
• When heavy dust or metal particles are present in the air,
install the unit inside proper housing with sufficient ventila-
tion.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -25 to +65
°
C
(-13 to +149
°
F) with relative humidity within 0 to 95% RH in
order to ensure adequate life span and operation.
■
WIRING
• Do not install cables (power supply, input and output) close
to noise sources (relay drive cable, high frequency line, etc.).
• Do not bind the unit's cables together with cables where
high noise levels are present. Do not install them in the same
duct.
■
AND ....
• The unit is designed to function as soon as power is
supplied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data sheet.
COMPONENT IDENTIFICATION
■
HOW TO OPEN THE COVER WHEN SETTING DIP SW
Hold at the top and bottom of the unit as shown below and
slide the housing cover gently to open until it hits the latching
inside the unit.
INSTRUCTION MANUAL
MODEL
M3LDY
CURRENT LOOP SUPPLY
(linearizing; field- and PC-configurable)
Specification Label
(side)
Body
SW Setting Label
• Housing Cover Fully Opened
Caution:
Handle the cover carefully to protect internal components from damage.
DO NOT pull beyond where the housing cover is latched. The plastic
housing may be damaged.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
M3LDY EM-2664 Rev.2 P. 2 / 6 ■ HOW TO SEPARATE THE TERMINAL BLOCKS When you need to separate the terminal blocks from thetransmitter body for wiring, insert a minus driver betweenthe terminal block and the housing body, pull up the driverand pull out the terminal block. DIN Rail 35mm wide Spring Loa...
M3LDY EM-2664 Rev.2 P. 3 / 6 EXTERNAL & INTERNAL VIEWS 8 7 6 5 4 3 2 1 ON OFF ON OFF 4 3 2 1 Configuration DIP SW 10 11 12 7 8 9 4 5 6 1 2 3 Configurator Jack DOWN Button UP Button MODE Button LED3 (LD3) LED2 (LD2) LED1 (LD1) ■ FRONT VIEW ■ SIDE VIEW SW2 SW1 ON OFF SW3 CONFIGURATION MODE & D...
M3LDY EM-2664 Rev.2 P. 4 / 6 CHECKING 1) Terminal wiring: Check that all cables are correctly connected according to the connection diagram.2) DIP SW setting: Check that the switches are set to appropriate positions.3) Power input voltage: Check voltage across the terminal 11 – 12 with a multimeter....