B&B Electronics 1939STB - Manual

B&B Electronics 1939STB

B&B Electronics 1939STB – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
Page: / 40

Table of Contents:

  • Page 2 – Table of Contents
  • Page 3 – Introduction; SAE Publications; Surface Vehicle Recommended Practice
  • Page 4 – Manual; Do Not Transmit Any Messages to The Network without a
  • Page 5 – Description; The power supply is a wide-range design and will accept a DC voltage
  • Page 6 – Physical Description; Serial Connection:; Electrical Specification
  • Page 7 – Communication directed to the device; The first two bytes (Check 1 and Check 2) are always set to 81hex and; Table 2. Transmit Data Format
  • Page 8 – Control Byte 3; the control code as follows:; Table 3. Bits of Byte 3; Table 6. Byte 3 Nibble 1
  • Page 9 – Control Byte 4; When control byte 3 is set to “external commands” (bit 4 set to 1), nibble; Table 8. Nibble 1 Bit Values
  • Page 10 – Internal Functions; MC Data; Table 9. Vendor String Setup
  • Page 11 – Table 11. Baud Rate Setup; Table 12. Baud Rate Setup
  • Page 12 – Table 13. Baud Rate Setup; Table 13 is set to produce a baud rate of 300, 1stop bit, an 8 bit data
  • Page 13 – Table 15. Parity Setup
  • Page 14 – Table 16. Stop Bit Setup; Table 17. Word Length
  • Page 15 – External Commands; The SAE-J1939 format is based on the CAN extended data frame. A
  • Page 16 – Message Header Setup; Before a message can be sent to the SAE-J1939 bus, the message header; Table 21. Valid Codes for Byte 4; Each message must have a unique slot number. A message sent; Table 20. Valid Codes for Byte 3
  • Page 17 – Message Information; The bit values shown in gray are the only values valid for the setup; Table 23. Two Bit Values for Byte 5 and 6
  • Page 18 – Byte 5
  • Page 19 – Byte 6; Transmit
  • Page 20 – XTD Bit2
  • Page 23 – Byte 7
  • Page 29 – Byte 11 is not sent to the J1939 bus and is coded as follows:; DLC Data Length Code; Number of bytes 0 to 8 in the data payload.; DIR Message Direction; The message is stored in this message location.
  • Page 30 – Data Field; through the converter.
  • Page 31 – Reception of Data; ID Byte
  • Page 32 – Function; This is used to show where the message came from. Refer to Table 37. If
  • Page 33 – Internal Messages; Table 39. Message Received from the SAE-J1939 Bus; Data
  • Page 34 – Software; Installation; If you follow all the default settings the program will be under
  • Page 35 – This screen is divided into two parts. The upper half of the screen
  • Page 36 – Message Transmission; The first row has 4 bytes. Bytes 1 and 2 are set to 8 and 21 hex. All; Message Reception; To receive information from the SAE-J1939 bus, the user must
  • Page 37 – Saving Message Information; To save a configuration: “the byte data”; File Logging
  • Page 38 – Appendix A; Priority; bits with a value of 0 to 7 - with 0 having the highest priority.; DP Data Page; bit. Sets an auxiliary page of parameter groups.; Source Address
  • Page 39 – Arbitration Field
  • Page 40 – Appendix B; Appendix B. Example
Loading the manual

1939STB4600 Manual

Cover Page

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104

B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445




RS-232 to J1939 Converter

CE

Model 1939STB

Documentation Number 1939STB4600

International Headquarters

B&B Electronics Mfg. Co. Inc.

707 Dayton Road -- P.O. Box 1040 -- Ottawa, IL 61350 USA

Phone (815) 433-5100 -- General Fax (815) 433-5105

Home Page: www.bb-elec.com

Sales e-mail:

[email protected]

-- Fax (815) 433-5109

Technical Support e-mail:

[email protected]

-- Fax (815) 433-5104


European Headquarters

B&B Electronics Ltd.

Westlink Commercial Park, Oranmore, Co. Galway, Ireland

Phone +353 91 792444 -- Fax +353 91 792445

Home Page: www.bb-europe.com

Sales e-mail:

[email protected]

Technical Support e-mail:

[email protected]


B&B Electronics – November 2000

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Table of Contents

1939STB4600 Manual Table of Contents i B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91 792444 – Fax +353 91 792445 Table of Contents INTRODU...

Page 3 - Introduction; SAE Publications; Surface Vehicle Recommended Practice

1939STB4600 Manual 1 B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91 792444 – Fax +353 91 792445 Introduction SAE-J1939 is a communication p...

Page 4 - Manual; Do Not Transmit Any Messages to The Network without a

2 1939STB4600 Manual B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91 792444 – Fax +353 91 792445 WARNING! This Model 1939STB Converter Modul...

Other B&B Electronics Models

All B&B Electronics Other