USER’S MANUAL

A03-HP1001 / A03-HP1501 / A03-HP2001 / A03-HP3001

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

This manual contains important safety instructions. Please follow all instructions carefully during installation. Read this

manual thoroughly before attempting to unpack, install or operate.

CAUTION:

To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area,

free of conductive contaminants.

CAUTION:

Risk of electric shock, do not remove the cover. No user

serviceable parts. Refer servicing to qualified service personnel.

CAUTION:

Risk of electric shock, hazardous live parts inside this UPS can be

energized from the battery supply even when the input AC power is

disconnected.

CAUTION:

Risk of electric shock, Battery Circuit is not isolated from AC input;

hazardous voltage may exist between battery terminals and

ground. Test before touching.

WARNING:

This is a Class A-UPS Product. In a domestic environment, this

product may cause radio interference, in which case, the user may

be required to take additional measures.

NOTICE:

The UPS is designed to be for use with computer loads only.

NOTICE:

To prevent injury, do not carry with the handle of front cover when

moving the UPS.

SETUP

1 Inspection

Inspect the UPS upon receipt. Notify the carrier
and dealer if there is damage. The package is
recyclable; save it for reuse or dispose of it
properly.

2 Place the UPS properly


3 Connect the loads

First, connect the UPS with Utility, then plug the
loads into the outlets on the rear of the UPS. To
use the UPS as a master “On/Off” switch, make
sure that all of the loads are switch “On”.
These UPS outlets provide battery power and
surge protection to the equipment when utility
voltage is outside acceptable limits.











Caution:

Do not connect a laser printer to the

UPS outlets.

4 Connect

Computer

Interface Port

Connect the supplied interface cable (RS-232 or
USB) to the interface port on the rear of the UPS
and the computer interface port. See software
installation guide in the CD-ROM (Optional) for
installation purpose.

5 Connect

Network

Surge protection

Connect a 10 base-T / 100 base-T network cable
into the RJ-45 network surge protection “IN” jack
on the rear of the UPS. Connect from the “OUT”
jack with network cabling to network equipment.

6 UPS Start Up

1. Connect the UPS to the wall receptacle.
2. Push the “On” Switch on the front panel of the UPS until 4 LEDs (LCD) are lit then extinguished

and release the “On” Switch.

3. The Backup mode LED (Amber) lights up and the UPS is under self-test mode now. If Utility is

normal, the UPS will run under Utility mode (Green LED) after its self-test is complete. On the
contrary, the UPS will run under Backup mode and the buzzer alarms every 2 seconds in case of
blackout or over/under voltage.

Caution:

1. The UPS “On” will not be executed if the above procedure is not done completely, which means

the button is released before all 4 LEDs (LCD) are extinguished.

2. The UPS will remain at “NO” output, if the start-up operation is not proceeded properly even

though the Input Power Cord is connected to the wall receptacle.

IMPORTANT NOTICE:

Plug the UPS into the wall receptacle to charge the UPS for over 10

hours after initial installation.

I N

O U T