Use the following instructions to update the firmware for the Aspire Wireless DSIU PCBs (P/N 0891090, 0891091,
0891092). The files used for updating the PCBs can be downloaded from the NEC Technical Support web site
(ws1.necii.com). This web site requires registration with the NEC Sales Support. Contact them by phone (1-800-365-1928)
or EMail ([email protected]) in order to register.

Updating the DSIU’s Firmware

1. Check Program 90-17-15 in the Aspire programming to

confirm the firmware version of the DSIU PCB.

2. Download the firmware update files and SIO application

from the NEC Technical Support web site.

3. Unzip the SIO application (WinZip application required

- this can be downloaded from www.winzip.com).

4. Copy the FLASH.KTB and FLASH2.KTB files into the

same directory as the SIO application.

5. Move the RUN/BLOCK switch to the BLOCK position.
6. Remove the DSIU from the system cabinet and position

the Application jumper located at the

top

of the PCB to

closed (place the jumper over both pins to connect them).

7. Reinstall the DSIU into the system cabinet.
8. Plug the special DIN terminated serial cable into the

upper 8-pin DIN connector

. Insert the 9-pin connector

into your PC’s serial port. Refer to the pinout informa-
tion in Figure 2 in order to create the required cable.

9. Start the SIO application by double-clicking on the

SIO.exe file.

10. After the screen loads with all the choices, press ENTER

then type

LOAD F

and enter again. You will then be

prompted for a password. enter

0000

.

The screen will then indicate the progression of the
flash loading with a twirling / . The file upload takes
approximately 5-8 minutes.

Next, update the CPU firmware using the following steps:
1. Rename the FLASH.KTB file to FLASH1.KTB. Rename

FLASH2.KB to FLASH.KTB.

2. Remove the DIN connector from the DSIU PCB.
3. Remove the DSIU from the system cabinet.
4. Move the jumper on the upper connection back to its original position (placed on

only one pin).

5. Position the CPU jumper located at the

bottom

of the PCB to closed (place the

jumper over both pins to connect them).

6. Replace the DSIU into the system cabinet.
7. Plug the special DIN terminated serial cable into the

lower 8-pin DIN connector

.

8. Start the SIO application by double-clicking on the SIO.exe file.
9. After the screen loads with all the choices, press ENTER then type

LOAD F

and

enter again. You will then be prompted for a password. enter

0000

.

The screen will then indicate the progression of the flash loading with a
twirling / . The file upload takes approximately 5-8 minutes.

When the second file is done:
1. Remove the DIN cable.
2. Remove the DSIU from the system cabinet.
3. Move the jumper on the lower connection back to its original position (placed on

only one pin).

4. Re-install the DSIU PCB into the system cabinet.
5. Move the RUN/BLOCK switch to the RUN position.
6. After the PCB has restarted, check Program 90-17-15 in the Aspire programming to

confirm the update version.

Aspire Wireless Firmware Update Instructions