Introduction
The neWR-5 is a programmable ethernet based remote control
unit for all Ashly NE (network enabled) products, including NE
processors and NE power amplifi ers. This remote brings control
features such as preset recall/scroll, mute, zone source selection,
individual channel and matrix point level control, and logic output
control throughout a building wherever there is a network con-
nection. All programming is done across the network using Ashly
Protea NE software.
Features
The neWR-5 is designed to mount into a standard North Amer-
ica electrical wall box. A decora cover plate (not included) can be
purchased at hardware stores to cover the neWR-5 electrical box and
satisfy the aesthetic needs of the installation.
Connecting and powering the neWR-5 is done using standard
Cat-5 ethernet cable and an IEEE 802.3af Power over Ethernet (PoE)
switch, hub, or inline PoE injector. If PoE is unavailable, a 15-
48VDC power supply capable of at least 2 watts per neWR-5 can be
hard wired to a euroblock connector on the back of the remote.
There is a hard-wired Lock-Out feature on the neWR-5, where
the closing of a switch wired to the lockout euroblock renders all
buttons inactive.
The neWR-5 has six programmable function buttons which can
light up green, red, or amber to display status. To the right of the
function buttons is a pocket in the mylar overlay for a paper function
label to be inserted. The two other buttons are used to adjust func-
tion parameters such as gain or preset number, and are indicated by
the LED display.
Hardware Installation
The neWR-5 Ethernet control connection is made using an RJ-45 terminated eight conductor
cable connected directly to a computer, or indirectly over a standard 10/100M Ethernet network.
Maximum cable distance for Ethernet is 100 meters from the nearest hub or switch for copper
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Operating Manual - neWR-5 Remote Control for NE Products 2 twisted pair CAT5 cable. If using PoE, no further power supply is required, otherwise connect a 15-48VDC power supply to the neWR-5 via the labelled euroblock connector. PoE current draw is 38mA @48VDC. If desired, wire the Lock Out con- nec...
3 Operating Manual - neWR-5 Remote Control for NE Products Main Control Surface The main control surface is where the neWR-5 is named, its target NE device gets selected, any zone defi nition occurs, and where the function buttons are programmed, The neWR-5 comes with all function buttons set to “Of...
Operating Manual - neWR-5 Remote Control for NE Products 6) Zone Source Selection - This function is used to assign a button to select one or more inputs for the defi ned zone (Select Zone Outputs) under neWR-5 control. Any function button can have any combination of inputs as sources. A zone source...