AOM561 Troubleshooting Guide
Monitor will not power up – no backlight on power button
•
Confirm 12v+ to monitor.
•
Confirm ground connection.
•
Check vehicle’s fuse and circuit for proper operation.
No image on screen
•
Verify cable is connected to monitor.
•
Verify camera is connected to cable.
•
Connect known good camera and cable to monitor.
o
If image appears connect cable to existing camera.
If image remains replace original cable.
If image disappears replace original camera.
Input does not trigger properly (Standby or otherwise)
•
See owner’s manual for proper wiring.
•
Confirm 12v + to trigger lead.
o
Note:
Trigger will remain active as long as there is 12VDC+ to that wire,
preventing control or access to other inputs/cameras.