Model 8100 Energy Recovery Ventilator
Installation Instructions
R E A D A N D S AV E T H E S E I N S T R U C T I O N S
CAUTION
1. Read all instructions before beginning installation.
2. The installation must conform to all applicable codes.
3. The fresh air duct from outside and to the house and the stale air duct from the unit to the outside must be fully insulated to
prevent condensation from forming on the duct work.
WARNING
1. Risk of property damage, injury or death. Installation, service, and maintenance must be performed by a qualified service
technician.
2. 120 Volts may cause serious injury from electric shock. Disconnect electrical power before starting installation or servicing.
Leave power disconnected until installation/service is completed.
3. The unit must be mounted in an upright position. Do not mount the unit with the access door facing down.
4. Sharp edges may cause serious injury from cuts. Use care when cutting plenum openings and handling duct work.
5. Inhalation of toxic gases or fumes can be harmful. The fresh air intake must be mounted in a location removed from sources
of dangerous toxic gases. All ducting must be separate from other household exhaust systems.
6. Insufficient combustion air may cause toxic conditions. The unit must not exhaust air from an enclosed room with
combustion appliances.
7. Excess negative or positive pressure may cause health problems or structural damage. The airflow must be balanced after
installation.
8. Dropping may cause personal injury or equipment damage. Handle with care and follow installation instructions.
SAfETy INSTRUCTIONS
TAblE Of CONTENTS
Safety Instructions
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Specifications
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Unpacking and Contents
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
location Considerations
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Mechanical Installation
Wall Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Ceiling Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Ducting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
balancing the System
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Equipment Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Balancing Airflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
System Start-up
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Constant On Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Operation with Home Comfort Control
™
. . . . . . . . . . . . . . . . . . . . . 10
Operation with 8120 Ventilation Controller
or Third-Party Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Troubleshooting
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
SpECIfICATIONS Dimensions Unit – 37-7/16” W x 12-3/4” D x 20-9/16” H EnergyMax Transfer Core – 12-1/8” x 12-1/8” x 10-3/4” Weight 75 lbs . performance 77% Apparent Sensible Effectiveness (ASE) At rated ventilation capacity with 72°F indoor temperature and 32°F outdoor temperature . Capacity Maximum ...
SERVICE CLEARANCE 12" 12" 36" 37-7/16" 20-9/16" CEILING MOUNTING HOLES CEILING MOUNTING HOLES ON / OFF SWITCH WALL MOUNTING HOLES WALL MOUNTING HOLES RETURN STALE AIR SUPPLY FRESH AIR EXTERNAL CONTROL WIRING ACCESS 6" ROUND COLLARS 12-3/4" 6" ROUND COLLARS 2" 2...
The unit can be mounted on a concrete wall or on a stud wall . The mounting bracket is pre-drilled for fastening to standard 16” O .C . or 24” O .C . stud spacing . Remove the access panel, EnergyMax Transfer Core, and air filters for installation .1 . Remove the access panel, EnergyMax Transfer Cor...