AprilAire 5000 - Manual

AprilAire 5000

AprilAire 5000 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 2 – fIGURE 1 – Dimensions of the Model 5000 Electronic Air Cleaner; SPECIfICATIONS; TAblE 1 – Model 5000 Specifications; Replacement Media; Consumes less than 50 watts with high voltage active; Max. Equipment Weight; Cabinet will support 400 lb. static load; DIMENSIONS; Outlet Side
  • Page 3 – COMPONENTS
  • Page 4 – lOCATING THE AIR ClEANER; figure 1
  • Page 5 – INSTAllING THE OUTER HOUSING AND INNER HOUSING ASSEMbly; OR; WARNING
  • Page 7 – Unit Off; Blue Light OFF; Unit ON; Blue Light ON
  • Page 8 – TROUblESHOOTING GUIDE; PROblEM
  • Page 9 – MAINTENANCE RECOMMENDATIONS; before performing any maintenance item listed below:; ClEAN THE CONTROl ElECTRODE
  • Page 10 – fIGURE 16 – Maintenance
  • Page 11 – APPlICATIONS WITH A HUMIDIfIER; An Aprilaire; CAUTION
Loading the manual

1

Model 5000 Electronic Air Cleaner

Installation Instructions

WARNING

120 Volts may cause serious injury from electrical shock.

Disconnect power to the furnace/air handler before
starting installation. Leave power disconnected until
installation is completed.

Arcing in electrical components may cause an explosion.

Do not install unit where explosive gasses will be present.

Sharp edges may cause injury from cuts.

Use care when

cutting and handling sheet metal.

To reduce the risk of electrical shock, this equipment

has a grounding-type (three prong) plug.

This plug will fit

only into a grounding-type power outlet. If the plug does
not fit into the outlet, contact qualified personnel to install
the proper outlet.

Do not alter this plug in any way.

To reduce the risk of electrical shock,

locate product

so that the power cord can be plugged into an electrical
outlet without the use of an extension cord.

CAUTION

To prevent component failure, do not install the air

cleaner on the warm air supply or in an area where

the temperature may exceed 140°F. This may include

areas above heat exchangers in downflow furnaces or
above exhaust flues in lowboy furnace cold air returns.

The air cleaner must be installed where the ambient

air temperature remains between 32°F and 140°F
[0°C and 60°C].

Installation must conform to all applicable codes.

Do not install an atomizing humidifier upstream of the
air cleaner. Water or mist will cause power supply to
shut down.

Do not plug the air cleaner into an outlet that is always

live. The outlet must only be live when the furnace/air
handler blower is operating. Failure to properly wire
the outlet can result in excessive ozone production.

Read the safety and installation instructions carefully. They will help ensure a correct and SAFE installation of the
Aprilaire

®

Electronic Air Cleaner.

SAfETy INSTRUCTIONS

Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Locating the Air Cleaner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Installing the Outer Housing and Inner Housing Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Wiring and Start Up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Troubleshooting Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Maintenance Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Applications with a Humidifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

TAblE Of CONTENTS

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - fIGURE 1 – Dimensions of the Model 5000 Electronic Air Cleaner; SPECIfICATIONS; TAblE 1 – Model 5000 Specifications; Replacement Media; Consumes less than 50 watts with high voltage active; Max. Equipment Weight; Cabinet will support 400 lb. static load; DIMENSIONS; Outlet Side

2 31" with Door 28-1/8" without Door 12" 24-5/8" 23-7/8" 15-1/2" 17-3/4" 18-3/8" 15-1/2" fIGURE 1 – Dimensions of the Model 5000 Electronic Air Cleaner 90-1346 SPECIfICATIONS TAblE 2 – Model 5000 Initial Airflow Resistance (inches w.c.) Airflow (CfM) 1000 1200 140...

Page 3 - COMPONENTS

3 Pleat Spacers (6) #501 Media Outer Housing with Door Retainers Inner Housing Assembly Inner Housing Ionizer frame Control Electrode Power Pack/Door Assembly On/Off Switch latches 90-1152 fIGURE 2 – Model 5000 Electronic Air Cleaner COMPONENTS

Page 4 - lOCATING THE AIR ClEANER; figure 1

4 lOCATING THE AIR ClEANER Airflow Airflow Airflow Airflow 30 max. 45 max. Minimize Angles Where Possible Airflow Plenum Box Airflow Plenum Box Size Plenum Box to fit outer housing without door: 17-3/4” x 28-1/8”. See figure 1 for complete dimensions. fIGURE 8 fIGURE 9 fIGURE 6 fIGURE 7 fIGURE 4 fIG...

Other AprilAire Models