AprilAire 1700 - Manual

AprilAire 1700

AprilAire 1700 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
Page: / 16

Table of Contents:

  • Page 2 – LOCATION NOTES
  • Page 3 – Note; The high side of the; DRAIN LINE; • The outlet from the dehumidifier to the HVAC supply duct must be; FIGURE 1; FIGURE 2
  • Page 4 – WHOLE HOUSE INSTALLATION AND OPERATION; REQUIRED COMPONENTS; FIGURE 3 – DUCTING
  • Page 5 – FIGURE 4 – WIRING; CYCLE TIME; TEST; CYCLE PERIOD; SYSTEM SETUP
  • Page 6 – LOCALIZED INSTALLATION AND OPERATION
  • Page 7 – FIGURE 7 – WIRING
  • Page 8 – WHOLE HOUSE / LOCALIZED CONVERTIBLE INSTALLATION AND OPERATION
  • Page 9 – FIGURE 10 – WIRING
  • Page 10 – VENTILATION / FAN CYCLING SETTINGS; For example: If the home requires; The Outdoor; DO NOT leave the CYCLE TIME in TEST.
  • Page 11 – House Size; VENTILATION GUIDELINES
  • Page 12 – DIP SWITCH DEFINITIONS; CONVERTIBLE; FLOAT SWITCH
  • Page 13 – SYSTEM CHECKOUT; Check the wiring to the HVAC equipment.
  • Page 14 – TROUBLESHOOTING GUIDE; SYMPTOM
  • Page 15 – Table 2; TABLE 2
Loading the manual

Wire

Routing

Port

Wiring

Access

Filter

Access

Humidity

Control

Inlet

Drain

On/Off

Switch

Filter

Access

Service

Access

Port

Outlet

Safety and Installation Instructions

Model 1700

Dehumidifier

INSTALLER – PLEASE NOTE!

1.

Installation must conform to all applicable codes.

2.

A dedicated 15 Amp circuit is required for proper
operation of the dehumidifier.

If a dedicated circuit

is not available, do not install unit.

3.

For protection of the compressor, unit must be
transported and installed in an upright position.

If the unit was shipped or stored on its side, a 24 hour
settling period is required before running the unit.

TABLE OF CONTENTS

Safety Instructions . . . . . . . . . . . . . . .2

Overview . . . . . . . . . . . . . . . . . . . . . . .2

Specifications . . . . . . . . . . . . . . . . . . .2

Location Notes . . . . . . . . . . . . . . . . . .2

Ducting . . . . . . . . . . . . . . . . . . . . . . . .3

Drain Line . . . . . . . . . . . . . . . . . . . . . .3

Hanging . . . . . . . . . . . . . . . . . . . . . . .3

Installations

Whole House . . . . . . . . . . . . . . . . . . .4

Localized . . . . . . . . . . . . . . . . . . . . . . .6

Whole House / Localized
Convertible . . . . . . . . . . . . . . . . . . . . .8

Ventilation and Fan Cycling . . . . . . .10

Float Switch . . . . . . . . . . . . . . . . . . .12

Dip Switch Definitions . . . . . . . . . . .12

System Checkout . . . . . . . . . . . . . . .13

Troubleshooting . . . . . . . . . . . . . . . .14

Sequences
of Operations . . . . . . . . . . .Back Cover

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - LOCATION NOTES

2 SAFETY INSTRUCTIONS OVERVIEW SPECIFICATIONS WARNING • This product must be installed by a qualified heating and air conditioning contractor. Failure to do so could result in serious injury from electrical shock or damage to product. • 120 volts may cause serious injury from electric shock. Disconn...

Page 3 - Note; The high side of the; DRAIN LINE; • The outlet from the dehumidifier to the HVAC supply duct must be; FIGURE 1; FIGURE 2

The included condensate trapmust be installed to the Model1700. Use PVC primer andcement to connect the trap to thedrain outlet on the Model 1700.The drain outlet is located nearthe On/Off toggle switch. Note orientation of trap prior tocementing. The high side of the trap mates with the Model 1700....

Page 4 - WHOLE HOUSE INSTALLATION AND OPERATION; REQUIRED COMPONENTS; FIGURE 3 – DUCTING

4 WHOLE HOUSE INSTALLATION AND OPERATION In this configuration the dehumidifier will pull air from the return duct. The air passes through the dehumidifier, where moisture isremoved, and then returned to the HVAC system downstream of the cooling coil in the supply plenum. This installation is usedwh...