Model 1610 Easy Install

Media Air Cleaner

Installation Instructions

1. High voltage may cause serious

injury from electrical shock.

Disconnect power to the

furnace/air handler before

starting installation.

2. Sharp edges may cause injury

from cuts. Use care when cutting

and handling sheet metal.

WARNING

1. To prevent component failure, do not install the air cleaner on the warm

air supply or in an area where the temperature may exceed 140°F. This

may include areas above heat exchangers in downflow furnaces or above

exhaust flues in lowboy furnace cold air returns.

2. Installation must be done by a qualified heating and air conditioning

professional. Read instructions thoroughly before beginning installation.

3. Do not install air cleaner downstream of a UV light. UV lamps will cause

degradation of the filtering media.

CAUTION

SPECIFICATIONS

Airflow Capacity:

up to 2000 CFM maximum

Replacement Media:

Model 410 or 413 with SelfSeal

Air Cleaner Operating Environment:

Temperature: 0°F – 140°F

DIMENSIONS

10-11479

FIGURE 1 – Air Cleaner Dimensions

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - The air cleaner has many features to make retrofit easier:; FIGURE 2; lOCATING THE AIR ClEANER

29” FOR FILTER REPLACEMENT 1. The air cleaner can be mounted on the right or left side of the HVAC equipment (see Figure 2 ). 2. The door can be facing the front or rear of the HVAC equipment cabinet (see Figure 2 ). 3. The door and blanking plate are reversible to allow filter access from the front...

Page 3 - The “L” bracket can removed to form a 10”x 24” drop opening. See; Figure 6; See; Figure 7; ) or transition pieces field fabricated; Figure 9; FIGURE 6

FIGURE 7 FIGURE 8 FIGURE 10 FIGURE 9 10-11490 10-11491 10-11498 10-11491 2. The “L” bracket can removed to form a 10”x 24” drop opening. See Figure 6 . 3. If the cold air drop is less than 24 inches deep an angle bracket can be field fabricated and installed to reduce the drop width. See Figure 7 . ...

Page 4 - Align filter in top and bottom rails; WARNING; If replacing an existing filter, remove the filter and; INSTAll THE AIR ClEANER CABINET

P.O. Box 1467 • Madison, WI 53701-1467 • Phone: 800/334-6011 • Fax: 608/257-4357 • www.aprilairepartners.com 10010740 3.14B2701329A Printed in U.S.A. © 2014 Aprilaire – A division of Research Products Corporation FIGURE 11 Expand clean filter. Align filter in top and bottom rails and slide into plac...

Other AprilAire Models