Page 2 - Contents
Contents Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower i Overview .......................................................................... 1 Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Safety . . . . . . . . . . . . . . . . . . . . ....
Page 4 - Overview; Product Description; Safety; Product Overview; Front panels
1 Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower Overview Product Description The APC ® by Schneider Electric Smart-UPS ® 750-3000 VA 120/230 Vac Tower is a high performance Uninterruptible Power Supply (UPS). It provides protection for electronic equipment from utility power blackouts, brow...
Page 5 - Rear panels
Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower 2 Rear panels USB port 750 VA 120 Vac 750 VA 230 Vac Serial port Ground screw Smart slot Circuit breaker UPS input Outlets EPO connector 1000/1500 VA 120 Vac 1000/1500 VA 230 Vac 2200 VA 120 Vac/3000 VA 120 Vac† 2200/3000 VA 230 ...
Page 6 - Specifications; Operating Conditions; Installation; UPS
3 Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower Specifications Operating Conditions This unit is intended for indoor use only. Select a location sturdy enough to support the weight of the UPS. Do not operate the unit where there is excessive dust, or the temperature or humidity are outside ...
Page 7 - Operation; Connect Equipment to the UPS; Rear Panel Features
Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower 4 Operation Connect Equipment to the UPS Note: The UPS will charge to 90% capacity in the first three hours of normal operation. Do not expect full battery run capability during this initial charge period. 1. Connect equipment to the outlets on ...
Page 8 - Display Interface; Standard menus; APC by Schneider
5 Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower Display Interface Overview Using the display interface Use U P and D OWN to scroll through the main menu options. Press E NTER to view the sub-menus under each main menu option. Press E SCAPE to exit a sub-menu and return to a main menu. Stand...
Page 9 - Advanced menus
Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower 6 Advanced menus The Advanced menus provide additional options for the UPS and are available only if the display interface is configured to use the Advanced menus. About Display information about this unit:• Unit model number• Serial number• Bat...
Page 10 - Configuration; UPS Settings; General Settings
7 Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower Configuration UPS Settings Start-up Settings Configure these settings at initial start-up, using the display interface or APC PowerChute ® software. Note: During start-up, use the display interface to configure these settings. If nothing is se...
Page 12 - Main Outlet Group and the Switched Outlet Group
9 Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower Main Outlet Group and the Switched Outlet Group Overview The Main Outlet Group and the Switched Outlet Group can be configured to independently turn off, turn on, shut down, and reboot connected equipment. (These features are not available on ...
Page 13 - Network Management Card Settings
Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower 10 Network Management Card Settings These settings are available only on units that have a Network Management Card (NMC) and are set in the factory. These settings can only be modified using an external interface, like the NMC web interface. • N...
Page 14 - Emergency Power Off; EPO Overview; Normally open contacts
11 Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower Emergency Power Off EPO Overview The Emergency Power Off (EPO) option is a safety feature that will immediately disconnect all connected equipment from utility power. The UPS will immediately shut down and will not switch to battery power. Th...
Page 15 - Troubleshooting
Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower 12 Troubleshooting Problem and Possible Cause Solution The UPS will not turn on or there is no output The unit has not been turned on. Press the ON button once to turn on the UPS. The UPS is not connected to utility power. Ensure that the power ...
Page 17 - Service and Support; Service
Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower 14 Service and Support Service If the unit requires service, do not return it to the dealer. Follow these steps: 1. Review the Troubleshooting section of the UPS manual to eliminate common problems. 2. If the problem persists, contact APC Custom...
Page 18 - Transport the unit; APC Worldwide Customer Support
15 Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower Transport the unit 1. Shut down and disconnect all connected equipment. 2. Disconnect the unit from utility power. 3. Disconnect all internal and external batteries (if applicable). 4. Follow the shipping instructions outlined in the Service ...
Page 19 - Smart-UPS Factory Warranty; LIMITED WARRANTY
Smart-UPS Factory Warranty LIMITED WARRANTY American Power Conversion (APC) warrants its Smart-UPS (Products) to be free from defects in materials and workmanship for a period of three (3) years, excluding the batteries, which are warranted for two (2) years from date of purchase. APC's obligation u...
Page 20 - EC Declaration of Conformity
Harmonized Standards EN62040-1-1, EN62040-2, EN60950-1, IEC60950-1, EN55022, EN55024, IEC61000-3-2, 3-3, 4-2, 4-3, 4-4, 4-5, 4-6, 4-11 Applicable Council Directives 2006/95/EC; 2004/108/EC Type of Equipment Uninterruptible Power Supply Model Numbers SMT750I, SMT1000I, SMT1500I, SMT2200I, SMT3000I Ma...