Place the Back-UPS ES to avoid:

- Direct sunlight
- Excessive heat
- Excessive humidity or contact with fluids

Plug the Back-UPS ES power cord directly into a wall outlet; not a
surge protector or power strip.

Connect FAX/Modem/Phone

Back-UPS ES protects a single line (2-wire) fax, modem or phone from
surges when it is connected through the Back-UPS ES as shown.

Connect Computer Cable

The supplied cable and software provide automatic file saving and
shutdown of the operating system in the case of a sustained power outage.

Connect the cable to the Data Port of the Back-UPS ES. Connect the other
end of the cable to the USB port on your computer. The software will
automatically find the USB Port of your computer.

Back-UPS ES 350/550

User Guide

1

2

3

Connect Battery

Connect Equipment

Power On and

Install Software

990-4993A Copyright 2006 American Power Conversion Corporation

All other trademarks are property of their respective owners.

For safety, the Back-UPS ES is shipped with one battery wire disconnected. The Back-UPS ES will not operate until the wire is connected to the touch

safe battery terminal.

NOTE

: Small sparks may occur during battery connection. This is normal.

1

TURN the Back-UPS ES over and

slide the battery compartment

cover off of the battery housing.

Surge Protection Only

These outlets provide full-time protection from surges even if

the Back-UPS ES is switched OFF. Plug your printer, fax

machine, scanner, or other peripherals that do not need

battery power into these outlets.

Battery Backup

Surge Protection

These outlets are powered whenever the Back-UPS ES is
switched ON. During a power outage or other utility problems
(brownouts, over-voltages), these outlets will be powered for a
limited time by the Back-UPS ES. Plug your computer, monitor,
and two other data-sensitive devices (external disk or tape drive)
into these outlets.

Press the ON/OFF switch to power the unit
ON.

A single short beep and the green “Power On”
indicator confirms that Back-UPS ES is on and
ready to provide protection.

The Back-UPS ES should charge for at least
16 hours to ensure sufficient runtime. The unit
is being charged whenever it is connected to
utility power, whether the unit is turned ON or
OFF.

If the red Building Wiring Fault indicator
(located on the end near the power cord) is lit,
your building wiring presents a shock hazard
that should be corrected by a qualified
electrician.

Install the PowerChute Personal

®

Edition

software

Place the PowerChute Personal Edition CD-
ROM into your computer and follow the
installation instructions on the screen.

2

LIFT the battery out of the compartment and connect the black wire to the negative (-) battery

terminal. Ensure the batteries are installed as shown below.

APC, the APC logo, Back-UPS and PowerChute are registered trademarks of American Power Conversion Corp.

The Back-UPS ES indicates operating status using a combination of visual and audible indicators.

Use the following table to identify the status of the Back-UPS ES.

Status

Visual Indications

(Power On - Green)

(Replace Battery - Red)

Audible Indication

Alarm Terminates

When

Power On

- UPS is supplying conditioned

utility power to the load.

Power On LED - ON

None

Not applicable.

On Battery

- UPS is supplying battery

power to the load connected to the Battery

outlets.

Power On LED - ON (off

during beep)

Beeping 4 times every

30 seconds

UPS transfers back to

Power On operation, or

when UPS is turned off.

Low Battery Warning

- UPS is supplying

battery power to the load connected to the

Battery outlets and the battery is near

exhaustion.

Power on LED - flashing

Rapid beeping (every

1/2 second)

UPS transfers back to

normal operation, or

when UPS is turned off.

Replace Battery

- The battery is

disconnected.

The battery is in need of charging or is at

the end of its usual life and must be

replaced.

Replace Battery LED -

flashing

Power On and Replace

Battery LEDs- Flashing

(alternating)

Constant tone

Constant tone

UPS turned off with the

power switch.

Overload Shutdown

- During On Battery

operation a battery power supplied outlet

overload was detected.

None

Constant tone

UPS turned off with the

power switch.

Sleep Mode

- During On Battery operation

the battery power has been completely

exhausted and the UPS is waiting for utility

power to return to normal.

None

Beeping once every 4

seconds

Utility power is restored,

or if utility power is not

restored within 32

seconds, or the UPS is

turned off.

Building Wiring Fault

- Your building

wiring presents a shock hazard that should

be corrected by a licensed electrician.

Building Wiring Fault LED

(red) - ON

None

UPS is unplugged, or is

plugged into a properly

wired outlet.

Status Indicators

®

See the Troubleshooting section for additional assistance.

Back-UPS ES 550

Slide the battery compartment cover

completely onto the Back-UPS ES.

3

Battery Backup

Surge Protection

Surge Protection Only

Power On

Replace Battery

Back-UPS ES

5 5 0

w

w

w.apc.com

®

POWER ON/

AC LINE

CORD

TO COMPUTER

USB PORT

FROM WALL JACK

DATALINE OUTPUT TO

DSL MODEM or PHONE

Data Port

Modem/

Phone/Fax

Wall

Outlet

CAUTION

- Refer to bottom

of unit for safety markings.

Circut Breaker

Push to Reset

Building

Wiring

Fault

BUILDING WIRING
FAULT INDICATOR

CIRCUIT BREAKER

PUSH TO RESET

REPLACE BATTERY

INDICATOR