APC BR900GI - Manual

APC BR900GI

APC BR900GI – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
Page: / 2
Loading the manual

10/100 Base-T / VOIP

CONNECT TVSS

Back-UPS

®

RS 900

User’s Manual

2

OPERATING ENVIRONMENT

3

CONNECT EQUIPMENT / POWER

Monitor

Printer or Scanner

FAX

External Disk or
CD / DVD Drive

Computer

4

CHECK BUILDING WIRING

FAULT INDICATOR

Building Wiring

Fault Indicator

5

Phone Jack

CONNECT PHONE/MODEM/FAX

7

CONNECT 10/100 Base-T

6

To Computer USB

Port

CONNECT INTERFACE

Computer

9

INSTALL SOFTWARE ON
COMPUTER

There are four status indicators (lights) on the front

panel of the Back-UPS (On Line, On Battery, Overload,

and Replace Battery).

On Line (green)

- is lit whenever utility power is

powering the Battery Backup outlets.

On Battery (yellow)

- is lit whenever the battery of

the Back-UPS is powering equipment connected to the

Battery Backup Outlets.

Four Beeps Every 30 Seconds

- this alarm is

sounded whenever the Back-UPS is running On

Battery. Consider saving work in progress.

Overload (red)

- is lit whenever power demand has

exceeded the capacity of the Back-UPS.

Continuous Tone

- this alarm is sounded

whenever the Battery Backup outlets are

overloaded.

Circuit Breaker

- the circuit breaker button

located on the rear panel of the Back-UPS will

stick out if an overload condition forces the Back-

UPS to disconnect itself from utility power. If the

button sticks out, disconnect non-essential

equipment. Reset the circuit breaker by pushing

the button inward.

Replace Battery (red)

- is lit whenever the battery is

near the end of its useful life, or if the battery is not con-

nected (see above). A battery that is near the end of its use-

ful life has insufficient run-time and should be replaced.

Chirps for 1 Minute Every 5 Hours

- this

alarm is sounded whenever the battery has failed

the automatic diagnostic test.

Note: Allow the Back-UPS to charge for a full eight (8)

hours prior to use.
Press the front panel Power ON/OFF switch and observe

that the following events occur after pressing and

releasing the switch:

• The green On Line indicator flashes.

• The yellow On Battery indicator lights while

a Self-Test is being performed.

• When Self-Test has successfully completed,

only the green On Line indicator will be lit.

• If the internal battery cartridge is not

connected (see Step 1 above), the green On

Line indicator and red Replace Battery

indicators will light. The Back-UPS will also

emit a chirping sound.

Continuous Beeping

- this alarm is sounded

whenever a low battery condition is reached.

Battery run-time is very low. Promptly save any

work in progress and exit all open applications.

Shutdown the operating system, computer and

the Back-UPS.

NOTE

: Macintosh Users - for full USB performance,

use OS 9.22 or higher.
If Autoplay is not enabled on the computer, proceed

as follows:
1. On the computer desktop of the display, double-

click on My Computer.

2. Double-click on the CD-ROM drive icon and

follow the on-screen instructions.

If the rear panel Building Wiring Fault (red)

indicator is lit, a potential shock hazard exists

due to one of the following conditions:
• Open or high resistance ground
• Hot or neutral polarity reversed
• Overloaded neutral circuit

Improper building wiring should be

corrected by a qualified electrician. Do not

use the Back-UPS until the condition that

caused the fault is corrected.
Note

: Improper building wiring will not

prevent the Back-UPS from operating, but it

will limit its protection capability.

8

SWITCH ON THE BACK-UPS

10

GROUND

The Back-UPS features a transient
voltage surge-suppression (TVSS)

screw for connecting the ground
lead on additional surge
suppression devices such as
network and data line surge
protectors.

From Data Line

TVSS

Follow the

on-screen

instructions.

On Line

On Battery

Overload

Replace Battery

RJ-45

USB

STATUS INDICATORS AND ALARMS

or VIOP

CABLE

TVSS GND

M

ode

m

/Fa
x/Phone

Wall

Outlet

Dat
a

P

o

rt

Building Wiring Fault

Circuit Breaker

Push to Reset

Input: 120V~

15A, 50-60Hz

BA
T

T

E

R

Y
B

A

C

KU
P

SURGE

O

NL
Y

TVSS GND

M

o

d

em

/Fa

x/P

h

one

Wall

Outlet

Da
ta

Po
rt

Building Wiring Fault

TVSS GND

M

ode

m

/Fa

x/P

hone

Wall

Outlet

Da
ta

P

o

rt

TVSS GND

M

ode

m

/Fa

x/P

h

o

n

e

Wall

Outlet

CONNECT BATTERY CARTRIDGE

1

(Back-UPS XS models only)

Computer

Modem Port

Mod

em/

Wall

Outlet

Da
ta

P

o

rt

10/100 Base-T / VOIP

To 120 VAC, 50-60 Hz

Back-UPS

®

XS 900

Network Jack

Computer

Network Port

32 - 104

o

F (0 - 40

o

C)

30 cm

w

w

w.apc.com

®

10/100 Base-T / VOIP

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other APC Models

All APC Other