APC 400kW1MW - Manual

APC 400kW1MW

APC 400kW1MW – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
Page: / 64

Table of Contents:

  • Page 2 – Battery Rack Assembly and Installation Manual
  • Page 3 – Contents
  • Page 7 – Safety; Safety warnings
  • Page 8 – Additional considerations; • Remove watches, rings, and other metal objects from your body.
  • Page 9 – Specifications; either Power or Fiamm battery types.; Weights and dimensions; Rack SKU
  • Page 10 – Shipping and Receiving; Shipping; are shrink-wrapped to the pallet for added stability.; Receiving; Keep boxes on pallet for transportation to installation site; Check for discrepancies.; Make certain the shipment has arrived in its entirety. Compare
  • Page 11 – Placement; Positioning; battery racks fit into the overall system.; Handling; installation position.; “Appendix C: Employing Sidecars” on page 44.
  • Page 12 – Installation Site; Installation considerations; mm
  • Page 13 – Parts List; installation until all parts are in your possession.; Description
  • Page 14 – Battery Cabling; style are detailed in “Appendix A: Battery Wiring Style E” on page 35.
  • Page 15 – Rack Assembly; Assembling the bottom section; The bottom section of the rack will contain shelves #3 and #4.
  • Page 16 – Refer to graphic in step 4 below.
  • Page 17 – Assembling the top section
  • Page 19 – Refer to graphic in step 6 below.
  • Page 21 – Stabilizing the rack
  • Page 22 – Numbering the batteries; in the wiring scheme.; Accessing your wiring diagrams; connecting batteries.
  • Page 23 – Positioning rails on shelves; points for placing rails. Make adjustments as necessary.; Addressing the bottom shelf; spacing, and later make adjustments as necessary.
  • Page 24 – the proper positioning of its positive and negative terminals.; Wiring the batteries; page 20, and “Covering battery connections” on page 21.; numbered batteries are placed on the lower shelves.; comply could result in serious injury or death!; Reading should approximate number of batteries in row times 12V.
  • Page 25 – battery in the second row using the supplied row-to-row cable.; Applying cable boots.
  • Page 26 – Connecting to batteries.; • Insert Terminal
  • Page 27 – Covering battery connections.; After each lug has been connected to its battery terminal, snap the; Addressing the third shelf; and later make adjustments as necessary.; Addressing the second shelf
  • Page 28 – spring nut is applied to each cross bar).; Addressing the top shelf
  • Page 29 – positioning of its positive and negative terminals.
  • Page 30 – Assembling the second rack; The battery racks must be deployed in multiples of two.
  • Page 31 – Labelling the terminal blocks; terminal block must be appropriately labelled.; Employing sidecars to support separated racks
  • Page 32 – Connecting terminal blocks to battery breakers; connections are made prior to
  • Page 33 – If using top cable entry, connect to top terminal (as shown) of the BAT
  • Page 34 – Connecting terminal blocks to batteries; terminal blocks TO the batteries. 120 mm
  • Page 35 – Before making connections, apply ONE cable boot. If lug
  • Page 36 – Before making connections, apply ONE cable boot. If
  • Page 39 – Reattaching terminal block covers; battery installation.; Grounding the racks
  • Page 40 – Glossary
  • Page 41 – Appendix A: Battery Wiring Style E; The following connections must be made to the TOP shelf in Rack #1:; Front of Battery Rack
  • Page 43 – The following connections must be made to the THIRD shelf in Rack #1:
  • Page 45 – The following connections must be made to the TOP shelf in Rack #2:
  • Page 47 – The following connections must be made to the THIRD shelf in Rack #2:
  • Page 49 – Appendix B: Battery Cabling Kits; References for Power battery cables:
  • Page 50 – Appendix C: Employing Sidecars; Sidecar overview; problem of power degradation.; input; bars and one horizontal; output; bar. The horizontal bars are “staggered” (in terms of
  • Page 51 – Positioning and accessing the sidecar
  • Page 52 – Connecting terminal blocks to sidecars; either of the two BAT 1+ vertical bars in the Sidecar.
  • Page 53 – either of the two BAT 1- vertical bars in the Sidecar.
  • Page 54 – either of the two BAT 2+ vertical bars in the Sidecar.
  • Page 55 – either of the two BAT 2- vertical bars in the Sidecar.; landing holes on the sidecar’s vertical bars.; Connect other cable end to
  • Page 56 – Connecting sidecars to battery breakers; Top
  • Page 57 – landings nearest the LEFT side of the; Front
  • Page 58 – landings nearest the RIGHT side of the
  • Page 59 – batteries” on page 28.
  • Page 63 – APC Warranty on Batteries; following conditions may put the warranty at risk.
  • Page 64 – APC Worldwide Customer Support
Loading the manual

Battery Racks for
400 kW–1 MW UPS Systems

Assembly and Installation Manual

This manual provides information pertaining to the assembly, loading, and wiring of those APC

battery racks designed to support the following Symmetra

®

MW UPS systems:

The basic components of each rack consist of frames, cross braces, support rails, and assembly

hardware. Refer to “Parts List” on page 7.

Read these instructions carefully, and observe all safety warnings and other precautions before

assembling racks or installing batteries. Should you require any assembly supervision, service, parts,

accessories or maintenance, call the appropriate APC number (refer to rear of document).

• 400 kW

• 800 kW

• 600 kW

• 1 MW

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Battery Rack Assembly and Installation Manual
Page 3 - Contents

Contents Battery Rack Assembly and Installation Manual i Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Safety warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Safety precautions . . . . . . . . . . . . . . . . . . . . . . ....

Page 7 - Safety; Safety warnings

Battery Rack Assembly and Installation Manual 1 Safety Safety warnings Safety precautions Warn in g • Only QUALIFIED ELECTRICIANS may perform this installation! Battery installation must be performed in accordance with all applicable codes! • Observe all WARNING and CAUTION notices! Failure to do so...

Other APC Models

All APC Other