Page 2 - AMX Limited Warranty and Disclaimer; determination of rights.
AMX Limited Warranty and Disclaimer AMX Corporation warrants its products to be free of defects in material and workmanship under normal use for three (3) years from the date of purchase from AMX Corporation, with the following exceptions: • Electroluminescent and LCD Control Panels are warranted fo...
Page 3 - Table of Contents
Table of Contents i IR Sensors and Receivers Table of Contents Product Information ................................................................................................. 1 Features ...............................................................................................................
Page 5 - Product Information; a swivel-mount enclosure for wall or ceiling installations.; Features; Are AXlink 38 or 455 kHz IR receivers
Product Information 1 IR Sensors and Receivers Product Information The AMX infrared (IR) sensors and receivers (AXD-IR+, AXR-IRSM+, IRX-DM+, and IRX- SM+) work with AMX IR-format 38 or 455 kHz wireless transmitters. The AXD-IR+ and AXR-IRSM+ are remote IR receivers used with AMX Axcess Central Contr...
Page 6 - Specifications: Sensors and Receivers
Product Information 2 IR Sensors and Receivers The swivel-mount units: ! Install on the ceiling or wall, and can be positioned horizontally or vertically ! Swivel for best IR reception and protection from fluorescent interference Specifications: Sensors and Receivers AXD-IR+ FIG. 2 shows the AXD-IR+...
Page 8 - Applications
Product Information 4 IR Sensors and Receivers The following table lists the IRX-SM+ specifications:. Applications Use the sensors and receivers with AMX transmitters to control devices such as media equipment. Combine several sensors and receivers for large single-area coverage or as discrete units...
Page 11 - Wiring and Installation; Setting the Receive Frequency
Wiring and Installation 7 IR Sensors and Receivers Wiring and Installation Before installing the sensors and receivers, set the receive frequency on the units. On the receivers, the AXD-IR+ and AXR-IRSM+, also set the AXlink device number and IR validation level. To access the jumper pins or switche...
Page 12 - Go on to the next procedure:; Configuring the Receivers; Setting the AXlink Device Number
Wiring and Installation 8 IR Sensors and Receivers ! To receive 455 kHz, position the jumper (both jumpers on the receivers) on the left two pins, pins 1 and 2, away from the edge of the circuit boards, to receive 455 kHz. (This is the default setting.) ! To receive 38 kHz, position the jumper (both...
Page 13 - enters the new device number into memory.; Setting the IR Validation Level; validate and accept the signal data.
Wiring and Installation 9 IR Sensors and Receivers As an example, the DIP switch in FIG. 12 defines device number 129 (1+128=129). If you later change the device number, remove and reconnect the AXlink connector. This enters the new device number into memory. 3. Go on to Setting the IR Validation Le...
Page 14 - Wiring the IR Sensors and Receivers; local 12 VDC power supply to the AXlink connector.
Wiring and Installation 10 IR Sensors and Receivers Wiring the IR Sensors and Receivers The IR Sensors and Receivers use a four-pin AXlink connector for power and data. If the distance between the panel and Central Controller exceeds power consumption limits, you can connect a local 12 VDC power sup...
Page 15 - wiring diagrams in this section.; Connecting the Wiring; Install the AXlink data/power bus wiring as shown in FIG. 15.; Wiring Specifications
Wiring and Installation 11 IR Sensors and Receivers the receiver or sensor and the Central Controller. The maximum wiring lengths are based on a minimum of 13.5 volts available at the Central Controller's power supply. If you install the IR sensor or receiver farther away from the Central Controller...
Page 16 - Wire the IR sensor to the AMX IR receiver as shown in FIG. 17.
Wiring and Installation 12 IR Sensors and Receivers Use a 12 VDC power supply when the distance between the Central Controller and the sensors or receivers exceeds the limits described in the Wiring Specifications table above. Make sure to connect only the GND wire on the AXlink connector when using...
Page 17 - Mounting the UniMount Sensor or Receiver; standard 1-gang wallbox with a minimum internal clearance of
Wiring and Installation 13 IR Sensors and Receivers If the LED is on and not flashing, disconnect the AXlink connector and recheck all AXlink connections. Afterward, reconnect the AXlink connector to the panel and verify the LED is flashing once per second. Mounting the UniMount Sensor or Receiver F...
Page 18 - Mounting the Swivel-Mount Sensor or Receiver; Installation Method A
Wiring and Installation 14 IR Sensors and Receivers Mounting the Swivel-Mount Sensor or Receiver FIG. 19 gives dimensions for the AXD-IRSM+ and IRX-SM+. To install the AXD-IR+ or IRX-SM+: Mount the unit according to FIG. 20 for mounting the unit flush to a flat surface without using the mounting bra...
Page 19 - Installation method B
Wiring and Installation 15 IR Sensors and Receivers Installation method B Use when installing a swivel-mount unit using the provided mounting bracket. ! On drywall, install using the included wall anchors. Use a 3/16-inch drill bit. ! On wood, install using the included #6 mounting screws. 1. If you...
Page 20 - Connect the unit to AXlink data/power bus.
Wiring and Installation 16 IR Sensors and Receivers a. Connect the unit to AXlink data/power bus. b. Check the AXlink LED. (LED should blink once per second.). c. Replace the housing. 3. Check that the IR receiver is on and is supplying power to the sensor.