Q: How will I know if battery needs to be replaced?
A: Valve does not open and sensor blinks 2 times
interrupted by pause for up to 7 days.

Q: Why has the flow rate of the faucet reduced
significantly?
A: Check and clean aerator and strainer.

Q: There is no flow out of faucet when I'm in the
sensor range?
A: Check sensor. If sensor blinks 2 times interrupted
by pause, replace battery, or call 1800-442-1902.

Q: Why does the faucet operate the opposite of
expected-Turns On when not in sensor range, but
turns off when in sensor range?
A: Sensor wires to solenoid are reversed. Black to -
& Red to + is correct.

Q: What is the normal operating pressure range?
A: Faucet will operate with supply pressures ranging
from 20-80 psi.

9

8

1. Remove ENCLOSURE COVER.

2. Close SUPPLY STOP (5) with 4mm Hex wrench.

Note: Keep water flowing out of faucet while shutting off.

3. Pull off Red (1) and Black (2) CONNECTORS from

SOLENOID VALVE

(3).

4. Unthread STRAINER (4) using a 7/16" socket.

5. Pull out the STRAINER (4) and clean with an old

toothbrush. Rinse thoroughly with water.

6. Install the STRAINER (4) back in its place and

tighten with a 7/16" socket.

Caution: do not over tighten strainer.

Note: It is recommended to clean strainer every 6

months.

7. Replace ENCLOSURE COVER. Tighten cover

screws firmly.

1. Remove AERATOR HOUSING (1) with KEY

supplied with faucet.

3. Remove AERATOR (2) from HOUSING (1).

2. Clean the AERATOR SCREENS (3) with a old tooth

brush to remove dirt.

4. Rinse Clean with water. Reassemble and install into

spout end. Be sure black seal washer is in place.

4

4

3

2

1

5

CLEAN

SCREENS

HOW TO CLEAN FILTER; Fig. 4

4

HOW TO CLEAN AND REMOVE

THE AERATOR; Fig. 5

5

Fig.4

2

3

Fig.5

CAUTION

Before opening ENCLOSURE

disconnect AC power supply.

1

CAUTION

GENERAL CLEANING; Fig. 7

1. For general cleaning use a damp, soft cloth to clean
the spout and the sensor.

2. For cleaning dirt use a soft cloth with diluted dish
washing detergent. Wipe the area using a wet cloth
and dry using a soft cloth.

Do not scratch the sensor when cleaning.

Avoid using anything that may scratch the spout
surface.
Never use polishing power, detergent or a
nylon scrub brush. They will damage the surface of the
spout or Sensor.

7

Fig.7

Fig.5

HOW TO CONVERT RIGID GOOSE

NECK SPOUT TO SWING SPOUT

Fig. 6

The GN SPOUT is shipped from the factory as a
rigid assembly. To convert the GN SPOUT into a
SWING SPOUT proceed as follows:

1. Remove SET SCREW (1) from back of GN SPOUT
(2) with a flat blade screwdriver. Fig. 6.

2. Install SWIVEL SET SCREW (3) into opening in the
GN SPOUT

(2).

SWIVEL SET SCREW

(3)

is found in

hardware bag within product box.

6

Fig.6

1

2

3

(USE SHORT

SET SCREW

FOR SWIVEL

SPOUT)

605P400

605P800

10

M 9 6 8 8 0 9

R e v . 1 . 2

M 9 6 8 8 0 9

R e v . 1 . 2

S E L E C T R O N I C

L A V A T O R Y F A U C E T S

CHROME

002

Replace the "YYY" with

appropriate finish code

HOT LINE FOR HELP

For toll-free information and answers to your questions, call:

1 (800) 442-1902

Weekdays 8:00 a.m. to 8:00 p.m. EST

IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)

Weekdays 8:00 a.m. to 7:00 p.m. EST

P r o d u c t n a m e s l i s t e d h e r e i n a r e t r a d e m a r k s o f A m e r i c a n S t a n d a r d I n c .

© A m e r i c a n S t a n d a r d I n c . 2 0 0 5

A923672-0070A

FAUCET SUPPLY

HOSE

M962411-0070A

MOUNTING KIT

A913202-0070A

WASHER

M962387-0070A

MOUNTING SCREW KIT

M950250-0070A

DC SOLENOID

VALVE ASSEMBLY

M950251-0070A

AC SOLENOID

VALVE ASSEMBLY

A922272-0070A

U GROMMET

A922251-0070A

SOLID GROMMET

A924162-0070A

SUPPLY HOSE

044912-0070A

MOUNTING NUT

M962388-0070A

SENSOR KIT

M923827-YYY0A

2.2 GPM AERATOR

066508-YYY0A

0.5 GPM AERATOR

6055.102

6055.105

6056.102

6056.105

6057.102

6057.105

Cast Spout

PRODUCT NUMBERS

Cast Spout

6055.153

6055.155

6056.153

6056.155

6057.153

6057.155

5-1/4" GN Spout

6055.163

6055.165

6056.163

6056.165

6057.163

6057.165

6" GN Spout

A922267-0070A

ROUND GROMMET

A923654-0070A

BATTERY 6VCR-P2

A950487-0070A

CIRCUIT BOARD DC

A950489-0070A

CIRCUIT BOARD

AC & MULTI AC

A922290-0070A

POWER SUPPLY

GROMMET

M950169-0070A

POWER SUPPLY

M962389-0070A

SOLENOID & SCREWS

A950507-0070A

FILTER

A950509-0070A

SUPPLY STOP

A918462-0070A

SOLENOID SCREWS

A922265-0070A

10 ft. MULTI EXTENSION WIRE

(for 6057 series only)

A950223-007L0A

SENSOR