American Standard 6028.201 - Manual
American Standard 6028.201 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 3 – NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS MUST BE; HOT
- Page 4 – o change direction of handle rotation, proceed as follows:
- Page 5 – Speed ConnectTM Drain; Troubleshooting Guide; CABLE ADJUSTMENT PROCEDURE; If Stopper does not raise up fully or sink drains too slowly:; STOPPER REMOVAL PROCEDURE
- Page 6 – STOPPER INSTALLATION PROCEDURE; rear; “Locked”; front; “Unlocked”; Unlocked Mode
M 9 6 8 8 3 3 R E V. 1 . 2
6028.201
D A Z Z L E
Certified to comply with ANSI A112.18.1
Installation
Instr uctions
C e n t e r s e t L a v a t o r y F a u c e t w i t h
Speed Connect™ Drain
Adjustable Wrench
Screwdriver
Channel Locks
Required tools
Tubing Cutter
1
INSTALL FAUCET
SINK OR
MOUNTING
SURFACE
POP-UP
CABLE
Turn off hot and cold water supplies before beginning.
Note: Putty is not required unless mounting surface
is uneven.
Apply a bead of PUTTY along the edge of
the underside of the BODY (1) if required.
Insert FAUCET
(1)
and CABLE CONNECTOR
(2)
through
mounting holes of Sink or mounting surface.
Fig.
A.
Assemble LOCKNUTS
(3)
onto SHANKS
(4)
from under
side of Sink. Hand tighten firmly.
Fig.
B.
2
2
4
3
3
4
1
Turn off hot and cold water
supplies before beginning.
CAUTION
(HAND TIGHTEN)
Fig.
A.
Fig.
B.
1
PUTTY
(IF REQUIRED)
Congratulations on purchasing your American Standard
faucet with Speed Connect drain, a feature found only on
American Standard faucets.
*Your new American Standard faucet is designed to work only with the Speed Connect drain. Heplful tips for
removing your current drain can be found in the Troubleshooting section of these instructions.
To ensure that your installation proceeds smoothly-please read these instructions carefully before you begin.
Speed Connect™ Drain*
• Fewer parts, installs in less time
• Never needs adjustment
• Guaranteed to seal properly the first time, every time.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
M 9 6 8 8 3 3 R E V. 1 . 2 COMPRESSION NUT 3/8” COMPRESSION CONNECTION COUPLING NUT FLEXIBLE SUPPLIES 3/8 O.D. BULL-NOSE RISERS Operate LIFT KNOB (1) to verify that STOPPER (2) opens and closes. Note: If STOPPER (2) does not open and close properly then refer to the “troubleshooting section” of thes...
M 9 6 8 8 3 3 R E V. 1 . 2 2 1 4 SERVICE 10 TEST INSTALLED FITTING With HANDLES (1) in OFF position, turn on WATER SUPPLIES (2) and check all connections for leaks. Remove AERATOR (3) . Operate both HANDLES (1) to flush water lines thoroughly. Replace AERATOR (3) . 5 2 CHECK DRAIN CONNECTIONS Operat...
M 9 6 8 8 3 3 R E V. 1 . 2 Speed Connect™ Drain Troubleshooting Guide Disconnect the Cable from the Drain by threading the Cable Connector (1) counter-clockwise. Fig. A. Look at the area on the Drain Body where the Cable was attached and locate the component labeled as “Cam” and “Cam Cap” in the ill...