American Standard 3353 - Manual

American Standard 3353

American Standard 3353 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
Page: / 2
Loading the manual

SAVE FOR FUTURE USE

1

7 3 0 1 1 1 5 - 1 0 0 R e v . C

P r o d u c t n a m e s l i s t e d h e r e i n a r e t r a d e m a r k s o f A S A m e r i c a , I n c .
© A S A m e r i c a , I n c . 2 0 1 0

2

Refer to instructions supplied with wall carrier for proper installation of 4-bolt support
system wall cavity requirements and rough-in information for waste outlet piping.

Closet Carrier Support
Putty Knife

Sealant
Tape Measure

Regular Screwdriver
Adjustable Wrench

Carpenters Level
Flush Valve

RECOMMENDED TOOLS AND MATERIALS

Pictures may not exactly define contour of china

Model 3351, 3352, 3353, 3354, 2257.001, 2633.100, 2634.001

AFWALL FLUSH VALVE
WALL-MOUNTED TOILETS

INSTALLATION INSTRUCTIONS

CAUTION: PRODUCT IS FRAGILE. TWO PEOPLE ARE RECOMMENDED FOR
HANDLING TO AVOID BREAKAGE AND POSSIBLE INJURY!

NOTE:

For proper operation product requires a minimum of 30 psi working line pressure

FIXTURE MOUNTING

Fixture studs should project
1-7/8" (48mm) from face of
finished wall.

Front View

Side View

FINISHED
WALL

1-7/8"
(48mm)

(4) STUDS

When installed,
top of seat is
17" to 19"
(432mm to 483mm)
from the finished
floor.

Meets the American Disabilities Act Guidelines and ANSI A117.1
Requirements for the Physically Challenged

Thank you for selecting American Standard – the benchmark of fine quality for
over 100 years. To ensure thisproduct is installed properly, please read these
instructions carefully before you begin. (Certain installations may require
professional help.) Also be sure your installation conforms to local codes.

!

F I N I S H E D W A L L

4 7 0 m m

( 1 8 - 1 / 2 " )

C / L O F S E A T P O S T
H O L E S 1 4 0 m m
( 5 - 1 / 2 " ) C E N T E R

6 6 0 m m

( 2 6 " )

7 3 m m
( 2 - 7 / 8 " )

133mm
(5-1/4" )

191mm
(7-1/2" )

292mm

(11-1/2" )

(4) 22mm

(7/8" )

HOLES

3 5 6 m m

( 1 4 " )

C/L OF
OUTLET

1 2 1 m m

( 4 - 3 / 4 " )

FINISHED

FLOOR

32mm
(1-1/4" )

1" N.P.T. OR C.W.T. SUPPLY

AS REQUIRED TO FLUSH VALVE

330mm

(13" )

19mm

(3/4" )

142mm
(5-1/4" )

83mm

(3-1/4" )

62mm

(2-1/8" )

1-1/2" SPUD

C / L

229mm

(9)

FINISHED WALL

470mm

(18-1/2")

C/L OF SEAT POST HOLES
140mm(5-1/2") CENTERS

660mm

(26

"

)

133mm
(5-1/4")

191mm
(7-1/2")

298mm

(11-3/4")

(4)

22mm (7/8")

DIA. HOLES

356mm

(14")

C/L OF
OUTLET

FINISHED

FLOOR

32mm
(1-1/4")

330mm

(13")

(3/4")

19mm

133mm

(5-1/4"

)

83mm

(3-1/4")

C/L

229mm

(9")

38mm (1-1/2") DIA. HOLE IN WALL

95mm
(3-3/4

"

)

FOR WALLS UP TO 1" IN THICKNESS FOR EACH INCH
ADDITIONAL THICKNESS OF WALL ADD 25mm (1) TO
MEASUREMENT SHOWN

89mm
(3-1/2")

1" C.W.T. OR N.P.T. SUPPLY
AS REQ'D NOT FURNISHED

121mm

(4-3/4")

VACUUM BREAKER

76mm(3") DIA. HOLE IN WALL
FOR 1-1/2" SPUD

254mm

(10")

41mm

(1-5/8")

38mm
(1-1/2")

62mm

(2-1/8"

)

184mm

(7-1/4

" )

or

381mm

(15

" )

or

432mm

(17

" )

184mm

(7-1/4")

or

381mm

(15")

or

432mm

(17")

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other American Standard Models

All American Standard Other