American Standard 2461.XXXW Series - Manual

American Standard 2461.XXXW Series

American Standard 2461.XXXW Series – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12
Loading the manual

INSTALLATION INSTRUCTIONS

791033-100 Rev. I

© American Standard Inc. 2003
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.

AMERICAST BRAND
ENGINEERED MATERIAL

CAMBRIDGE™

WHIRLPOOL/BATHING POOL

2460.XXXW SERIES
2461.XXXW SERIES

FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.

1 - 1 / 2 N . P . T . T H R E A D S

1 - 1 / 2 O . D . T A I L P I E C E

4 4 1 m m

( 1 7 - 3 / 8 )

7 0 m m
( 2 - 3 / 4 )

1 1 7 m m

( 4 - 5 / 8 )

R O U G H
F L O O R

1 0 2 m m

( 4 )

451mm

(17-3/4)

2 4 m m

( 1 5 / 1 6 )

406mm

(16)

OPTIONAL
TO FLOOR

USUALLY

BETWEEN

1651 & 1981mm

(65 & 78)

7 1 1 m m

( 2 8 )

C/L OF CURTAIN ROD

USUALLY 1930mm(76) FROM

FINISHED FLOOR

C/L OF

VALVES

1 0 2 m m

( 4 )

1 0 2 m m
( 4 )

SPOUT-
1/2 N.P.T.

FINISHED
WALL

SHOWER ARM- 1/2 N.P.T.

32mm(1-1/4) DIA. HOLE

SEE

NOTE

7 6 m m
( 3 )

8 1 3 m m
( 3 2 )

1 5 2 4 m m

( 6 0 )

1 9 m m

( 3 / 4 )

70mm
(2-3/4)

203mm
(8)

FINISHED
WALL

1 0 2 m m

( 4 )

1 0 2 m m
( 4 )

C/L OF 1/2
SUPPLIES
AS REQ'D

C/L OF
DRAIN

229mm x 305mm
(9 x 12)
FLOOR
CUTOUT

PUMP

4 0 6 m m

( 1 6 )

PROVIDE ACCESS TO PUMP FOR

SERVICING ON ALL INSTALLATIONS

ON / OFF

SWITCH

6 4 m m

( 2 - 1 / 2 )

2 5 m m
( 1 )

(2) 54mm(2-1/8)

DIA. HOLES

6 0 m m 1 3 m m

+

( 2 - 3 / 8 ) ( 1 / 2 )

+

GENERAL SPECIFICATIONS FOR 2460/2461 WHIRLPOOL

WHIRLPOOL ELECTRICAL SPECIFICATIONS

SYSTEM I PUMP
SAFETY HEATER

1.6 HP, 9.7 AMPS,120V.

12 AMPS, 120V.

6 0 x 3 2 x 1 7 - 3 / 4 I n . ( 1524 x 813 x 451mm)

190 Lbs. (86 Kg.)

607 Lbs. (273 Kg.)

50 Gal. (190 L)
39 Gal. (148 L)

41 x 20 In. (1041 x 508mm)
54 x 26 In. (1372 x 660mm)

14 In. (356mm)

46 Lbs./Sq.Ft. (220 Kgs./Sq.m)

15.6

31.5

INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT

3

)

T H A N K Y O U . . .

for selecting an American Standard bath. Your new
bath is shipped to you after careful inspection. The
whirlpool version is completely assembled with pump,
motor, and system piping. All you need to finish the
installation are your selected fittings and electrical
connections for a whirlpool.

To insure maximum performance and pleasure from
this product, please follow the instructions and
cautions.

GENERAL INSTALLATION INFORMATION

Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor
immediately.

After inspection and during installation, protect the bath from construction damage. After installation, and before
enclosing with wallboard, tile, etc., water test the unit and check for leaks.

Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect
the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump,
motor, or piping system.

Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and
enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead
(required for recess installations).

Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.

WARNING! Do not lift whirlpool by the piping harness at any time.

List of Optional Components (not included):
• Safe-T-Heater 9075.120*

* see your American Standard Distributor

List of Required Components (not included):
• Drain 1583.470*
• Bath Filler*

* see your American Standard Distributor

List of Required Tools and Supplies:

Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard
Woodworking Tools
• Personal Safety
Equipment
• Caulking Gun

Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 4
Stringers
• Drop Cloth
• 15 amp GFCI
Outlet
• Cement, Plaster,
Grout

S A F E - T - H E A T E R
R E M O V A B L E B L A N K

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other American Standard Models

All American Standard Other