C L

TO RAISE

WATER

LEVEL

FLAPPER
ASSEMBLY

TO LOWER

WATER

LEVEL

TRIP

LEVER

FLUSH
VALVE

WATER

INLET

OVERFLOW

TUBE

FIG. 10A

WATER

LINE

LEVEL

+

WATER

CONTROL

ASSEMBLY

-

FLOW RATE

ADJUSTMENT

REFILL

TUBE

LIFT

ROD

FLOAT

BALL

RECOMMENDED TOOLS AND MATERIALS

Putty Knife

Regular Screwdriver

Adjustable Wrench

Wax Ring/Gasket

Flexible Supply Tube

Tape Measure

Closet Bolts

Hacksaw

Sealant

Carpenters Level

Seat

1

REMOVE OLD TOILET

a. Close toilet supply valve and flush tank completely. Towel or sponge remaining water from tank and bowl.
b. Disconnect and remove supply line. NOTE:

If replacing valve, first shut off main water supply!

c. Remove old mounting hardware, remove toilet and plug floor waste opening to prevent escaping sewer gases.
d. Remove closet bolts from flange and clean away old wax, putty, etc. from base area.

NOTE:

Mounting surface must be clean and level

before

new toilet is installed!

SAVE FOR FUTURE USE

3

2

ROUGHING-IN DIMENSIONS:

NOTE:

Distance from wall to closet flange centerline

must be as listed below:

For 120012 Tanks: Rough-in distance is 305mm (12")

7301311-100 Rev.A

CAUTION: PRODUCT IS FRAGILE. TO AVOID BREAKAGE AND POSSIBLE INJURY HANDLE WITH CARE!

NOTE:

Pictures may not exactly define contour of china and components.

!

ChinaLux 1000 EL
ChinaLux 1000 RF

POSITION TOILET ON FLANGE

a. Unplug floor waste opening and install toilet on
closet flange so bolts project through
mounting holes.
b. Loosely install retainer washers and nuts. Side of
washers marked “THIS SIDE UP”

must

face up!

a. Position toilet squarely to wall and, with a rocking
motion, press bowl down fully on wax ring and flange.
Alternately tighten nuts until toilet is firmly seated
on floor.

CAUTION:

DO NOT OVERTIGHTEN NUTS

OR BASE MAY BE DAMAGED!

b. Install caps on washers. (If necessary, cut bolt height
to size before installing caps.)
c. Smooth off the bead of sealant around base.
Remove excess sealant.

a. Install large rubber gasket over threaded

outlet on bottom of tank and lower tank
onto bowl so that tapered end of gasket
fits evenly into bowl water inlet opening.

b. Insert tank mounting bolts and rubber

washers from inside tank, through
mounting holes and gasket, and secure
with metal washers and nuts.

c. With tank parallel to wall, alternately

tighten nuts until tank is
snugged down evenly
against bowl surface.

INSTALL TOILET SEAT

Install toilet seat in accordance with manufacturer’s directions.

CLOSET

BOLT

NUT

TAPERED
WASHER

!

INSTALL WAX SEAL

Invert toilet on floor (cushion to prevent damage),
and install wax ring evenly around waste flange
(horn), with tapered end of ring facing toilet. Apply
a thin bead of sealant around base flange.

!

CAUTION:

DO NOT OVERTIGHTEN NUTS MORE
THAN REQUIRED FOR A SNUG FIT!

TANK MTG.

BOLTS

NUT

WASHER

RUBBER
GASKET

RUBBER
WASHER

ADJUSTMENTS

a. Flush tank and check that
tank fills and shuts off within
30 to 60 seconds, and tank
water level is set as
specified on tank rear wall.
b. To adjust water level:

turn water level adjustment
screw counterclockwise to
raise level; turn adjustment
screw clockwise to lower level.

c. To adjust flow rate (tank fill time):

turn flow rate adjustment screw
clockwise to decrease flow rate (increase fill time); turn adjustment screw
counterclockwise to increase flow rate (decrease fill time).

d. Carefully position tank cover on tank.
e. The flush valve float has been factory set and does not require adjustments.

Repositioning of the float will change the amount of water used which may
effect the toilet's performance.

f. If bowl fails to siphon, an adjustment may be required with the lift chain. Simply

remove the chain from the retainment clip (see Fig. 10) and take up slack on
the chain, and reinsert on lift rod. Make sure the chain is not too taught.

a. Connect water supply line
between shutoff valve and
tank water inlet fitting. Tighten
COUPLING NUT 1/4 turn
beyond hand tight. Check
that refill tube is inserted into
overflow tube.

b. Turn on supply valve and
allow tank to fill until float
rises to shutoff position.

c. Check for leakage at fittings,
tighten or correct as needed.

d. Do not use plumber's putty to
seal these fittings.

TANK

COUPLING NUT

FLEXIBLE
SUPPLY

WATER INLET

COMPRESSION
COLLAR

WASHER

VALVE NUT

TRIM PLATE

VALVE

CAUTION:
Overtightening of
COUPLING NUT could
result in breakage and
potential flooding.

INSTALL CLOSET BOLTS

Install closet bolts in flange channel, turn 90°, and slide into
place 6" (152 mm) apart and parallel to wall.

INSTALLATION INSTRUCTIONS

CARE AND MAINTENANCE

To ensure this product is installed properly, please read these instructions carefully before you begin.
Certain installations may require professional help.) Also be sure your installation conforms to local codes.

BOLT
CAP

10

9

8

7

6

5

4

CONNECT WATER SUPPLY

INSTALL TANK

INSTALL TOILET

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other American Standard Models

All American Standard Other