American Standard 0571.000 - Manual

American Standard 0571.000

American Standard 0571.000 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
Page: / 1
Loading the manual

J33

BARRIER FREE

© 2008 AS America Inc.

FINISHED

WALL

OR

SPLASH BACK

COUNTERTOP
CUTOUT 324mm
(12-3/4) DIA.

175mm

(6-7/8)

349mm

(13-3/4)

38mm

(1-1/2)

MIN.

51mm

(2)

MIN.

B

A

C/L

1-1/4 O.D.

TAILPIECE

1-1/4 O.D.

WASTE

203mm

(8)

168mm

(6-5/8)

178mm

(7)

16mm

(5/8)

COUNTERTOP

(BY OTHERS)

SEALING

COMPOUND

SUPPLIES

AS REQ'D.

305mm

(12)

*

254mm

(10)

*

FINISHED

FLOOR

787mm

(31)

SUGGESTED

848mm

(33-3/8)

FITTING

CENTER-SET

SPREAD

A

27mm(1-1/16)

32mm(1-1/4)

B

102mm(4)
203mm(8)

848mm

(33-3/8)

51mm

(2)

610mm

(24)

152mm

(6)

MAX.

BARRIER FREE

CLEARANCE

686mm

(27)

MIN.

203mm

(8)

MIN.

229mm

(9)

MIN.

DRAWING FOR

DIMENSIONAL

PURPOSES ONLY.

IT IS NOT AN EXACT

REPRESENTATION.

ROYTON™

COUNTERTOP SINK

VITREOUS CHINA

ROYTON™ COUNTERTOP SINK

• Made from vitreous china
• Self-rimming with cutout template supplied
• Center drain outlet
• Front overflow

0571.000

Round sink without faucet deck

Nominal Dimensions:

349mm (13-3/4") Round

Bowl size:

273mm (10-3/4") round
140mm (5-1/2") deep

Compliance Certifications -
Meets or Exceeds the
Following Specifications:

• ASME A112.19.2M for
Vitreous China Fixtures

To Be Specified:

Color:

White

Bone

Linen

Silver

Fawn Beige

Black

Faucet*:

Faucet Finish:

Supplies:

1-1/4" Trap:

* See faucet section for additional models available

MEETS THE AMERICANS WITH DISABILITIES ACT GUIDELINES
AND ANSI A117.1 ACCESSIBLE AND USABLE
BUILDINGS AND FACILITIES - CHECK LOCAL CODES.

Install lavatory 864mm (34") from finished floor.
Lavatory installed 51mm (2") minimum from front edge
of countertop provides 686mm (27") knee clearance area.

NOTES:

*

DIMENSIONS SHOWN FOR LOCATION OF SUPPLIES AND “P" TRAP

ARE SUGGESTED.

FOR COUNTERTOP CUTOUT AND INSTALLATION INSTRUCTIONS USE

TEMPLATE SUPPLIED WITH SINK.

FITTINGS NOT INCLUDED WITH FIXTURE AND MUST BE ORDERED

SEPARATELY.

SEALING COMPOUND SUPPLIED BY OTHERS.

IMPORTANT:

Dimensions of fixtures are nominal and may vary within the

range of tolerances established by ANSI Standard A112.19.2.

These measurements are subject to change or cancellation. No responsibility

is assumed for use of superseded or voided pages.

Revised 2/08