Amana VR8205- User Manual

Amana VR8205

Amana VR8205– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
Page: / 10

Table of Contents:

  • Page 2 – Up to; Table 1; II. Pressure Switch Installation; CAUTION; Figure 1
  • Page 3 – Derates
  • Page 4 – III. Orifice Installation; Remove the gas manifold by removing the burner box
  • Page 5 – Tighten orifices with a box-end wrench. Do not use a; Orifice
  • Page 6 – IV. Propane Gas Conversion; WARNING
  • Page 7 – OUTLET
  • Page 8 – Manometer; Single Stage Furnaces
  • Page 9 – Table 6; Natural Gas Firing Rates; Table 7; a. Turn off gas supply to all other appliances except the
  • Page 10 – For propane gas conversions, attach conversion data; VI. Complete The Installation; Check Burner Flames
Loading the manual

Amana

Fayetteville, TN 37334

!

RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION.

ATTENTION INSTALLING PERSONNEL

As a professional installer you have an obligation to
know the product better than the customer. This
includes all safety precautions and related items.

Prior to actual installation, thoroughly familiarize yourself
with this Instruction Manual. Pay special attention to all
safety warnings. Often during installation or repair it is
possible to place yourself in a position which is more
hazardous than when the unit is in operation.

Remember, it is your responsibility to install the product

safely and to know it well enough to be able to instruct
a customer in its safe use.

Safety is a matter of common sense...a matter of
thinking before acting. Most dealers have a list of
specific good safety practices...follow them.

The precautions listed in this Installation Manual should
not supersede existing practices but should be
considered as supplemental information.

A higher standard of comfort

Heating

¡

Air Conditioning

®

July 1998 (2)

10759906

KIT INCLUDES:

HANG07 (High Altitude Natural Gas) - installation instruc-

tions, orifices, wire ties.

HALP09 (High Altitude Propane Gas) - installation in-

structions, propane orifices, valve conversion kits
with instructions, conversion rating plate, conver-
sion date certificate, wire ties, and screen/turbulator
removal warning tag.

HAC1PS** (High Altitude Category I Pressure Switch) -

installation instructions, pressure switch.

IMPORTANT NOTE: These kits are approved for use on
Amana furnace models listed on the following page only. All
of the models listed have an Annual Fuel Utilization Effi-
ciency (AFUE) of 80%.

THE INSTALLATION AND SERVICING OF THIS EQUIPMENT SHOULD BE PERFORMED ONLY BY QUALIFIED,
EXPERIENCED TECHNICIANS.

THIS KIT IS NOT INTENDED FOR USE IN CANADA. THE AMANA 80% FURNACES ARE CGA CERTIFIED TO 4500
FEET ONLY.

WARNING

This conversion kit shall be installed by a
qualified agency in accordance with the
manufacturer’s instructions and all appli-
cable codes and requirements of the au-
thority having jurisdiction. If the informa-
tion in these instructions is not followed
exactly, a fire, explosion or production of
carbon monoxide may result causing prop-
erty damage, personal injury or loss of life.
The qualified service agency performing
this work assumes responsibility for the
proper conversion of this appliance with
this kit.

HANG07, HALP09, and

HAC1PS01-HAC1PS14

High Altitude Conversion Kit

Installation Instructions

Affix this manual, Specification Sheet and Users Informa-

tion Manual adjacent to the furnace.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Up to; Table 1; II. Pressure Switch Installation; CAUTION; Figure 1

2 I. Description HANG07, HALP09, and HAC1PS01-14 conversion kits arerequired when installing the following units above theirmaximum rated altitudes: Amana Air Command 80 SSE Amana Air Command SSE II Amana Air Command SSEIIQ Amana SV furnaces Amana Packaged Gas/Electric Units: PGA/B/D**C Increases in...

Page 3 - Derates

3 Table 2 Pressure Switch Kits (Category I Venting Only) HAC1PS Nat. Gas Derates (See Sec. V) 01 02 03 04 05 06 07 08 09 10 11 12 13 14 GUI(A/B)045(A/B) 7501 - 9500 ft 9501 - 11000 ft 34±4%42±4% XX GUI(A/B)045(CA/CX) 7501 - 9500 ft 9501 - 11000 ft 34±4%42±4% XX GUI(A/B)070(A/B/CA/CX) 7501 - 9500 ft ...

Page 4 - III. Orifice Installation; Remove the gas manifold by removing the burner box

4 HATS01 HATS02 HATS03 HATS04 HATS05 HATS06 HATS07 HATS08 HATS09 GUI(S,V)070 X X GUI(S,V)090 X X GUI(S,V)115 X X GUI(S,V)140 X X GCIS070 X X GCIS090 X X Low Pressure Switch "WC -0.37 -0.37 -0.37 -0.32 -0.27 -0.32 -0.32 -0.27 -0.23 High Pressure Switch "WC -0.66 -0.6 -0.55 -0.55 -0.46 -0.55 -...

Other Amana Models