Amana ADV8- User Manual
Amana ADV8– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Table of Contents
- Page 4 – WNER; III; RANSPORTATION; Keep this literature in a safe place for future reference.; WARNING; CARBON MONOXIDE POISONING HAZARD
- Page 5 – must
- Page 6 – American National Standards Institute; IV. LOCATION REQUIREMENTS AND CONSIDERATIONS; ENERAL
- Page 7 – C o u n t e r f l o w I n s t a l l a t i o n o v e r a c o m b u s t i b l e f l o o r .; f o r s e r v i c i n g; Suspended Furnace
- Page 8 – National Fuel Gas Code NFPA 54/ANSI; (b) Equipment shall be installed in a location in which the; HERMOSTAT; Thermostat Influences; V. COMBUSTION AND VENTILATION AIR REQUIREMENTS; W A R N IN G
- Page 9 – Equipment Located in Confined Spaces; Equipment Located in Confined Spaces All Air from Outdoors—; When communicating with the outdoors through vertical; Equipment Located in Confined Spaces All Air from Outdoors; . W h e n c o m m u n i c a t i n g w i t h t h e o u t d o o r s t h r o u g h; Equipment Located in Confined Spaces
- Page 10 – Equipment Located in Confined Spaces All Air from Outdoors -; UPFLOW; MODEL; Upflow or Horizontal units
- Page 11 – Venting; Upflow Rotated Induced Draft Blower; Counterflow units; CATEGORY I FURNACES ONLY; A F U E; Second Floor; Basement Floor; Figure 8 - Typical Multiple Flue Clay Tile Chimney; HECKLIST
- Page 14 – VIII. ELECTRICAL CONNECTIONS
- Page 15 – Line voltage wiring; Integrated Ignition Control
- Page 16 – Wire routing must not interfere with circulator blower; INGLE; Two-Stage Heating with Single-Stage Cooling; Thermostat Diagrams; timed
- Page 17 – Air Cleaner; Control Module; Optional; Figure 15 - Accessories Wiring; IX. GAS SUPPLY AND PIPING
- Page 18 – CAUTION; Natural Gas; ORIFICE SIZE; The input to the furnace must be checked AFTER reorificing.
- Page 19 – not; High; Pressure Switch Changes; Setting; Natural Gas Capacity of Pipe
- Page 20 – Rigid metallic pipe and fittings.; Drip Leg; General Furnace Layout; When the gas piping enters through the right side of the furnace; Never exceed specified pressures for testing. Higher; WARN ING
- Page 21 – Pipe or; X. CIRCULATING AIR AND FILTERS
- Page 22 – XI. SEQUENCE OF OPERATION; balance; Furnace Input; Minimum Filter Sizes
- Page 23 – HITE; Troubleshooting Chart
- Page 24 – White-Rodgers Model 36G54 Connected to Manometer; Inlet Gas Supply Pressure; Manifold Gas Pressure
- Page 25 – Temperature Rise Measurement; OFF
- Page 27 – O F F; Heat Off Delay S; Items in this section refer to the; air circulator blower fan; Switches viewed in an upflow installation.; Adjustment Switches; XIII. OPERATIONAL CHECKS; Burner Flame
- Page 28 – XIII. SAFETY CIRCUIT DESCRIPTION
- Page 29 – Internal Filter Removal
- Page 30 – “Operational; XVII. BEFORE LEAVING AN INSTALLATION
- Page 31 – ON; FLASH
- Page 33 – Wiring Diagram - AMV8
- Page 34 – Wiring Diagram - ADV8
- Page 35 – Quality Makes the Difference!; There’s No Better Quality.
These furnaces comply with requirements
embodied in the American National Standard
/ N a t i o n a l Sta n d a r d o f C a n a d a A N S I
Z 2 1 . 4 7 · C S A - 2 . 3 G a s F i r e d C e n t r a l
Furnaces.
RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION.
ATTENTION INSTALLING PERSONNEL
As a professional installer you have an obligation to know the product better than the customer. This includes all
safety precautions and related items.
Prior to actual installation, thoroughly familiarize yourself with this Instruction Manual. Pay special attention to all
safety warnings. Often during installation or repair it is possible to place yourself in a position which is more hazardous
than when the unit is in operation.
Remember, it is
your
responsibility to install the product safely and to know it well enough to be able to instruct a
customer in its safe use.
Safety is a matter of common sense...a matter of thinking before acting. Most dealers have a list of specific good
safety practices...follow them.
The precautions listed in this Installation Manual are intended as supplemental to existing practices. However, if there
is a direct conflict between existing practices and the content of this manual, the precautions listed here take
precedence.
*NOTE: Please contact your distributor or our website for the applicable product data book referred to in this manual.
INSTALLATION & OPERATING
INSTRUCTIONS for AMV8 AND ADV8
GAS FIRED WARM AIR FURNACE
2-STAGE
10/05
©
2004-2005 Goodman Manufacturing Company, L.P.
(CATEGORY 1)
C
US
®
IO-247C
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 IO-247C 10/05 Table of Contents T O T HE O WNER ....................................................................................................................................................... 4 T O T HE I NSTALLER ...............................................................................
4 IO-247C 10/05 WARNING S HOULD OVERHEATING OCCUR OR THE GAS SUPPLY FAIL TO SHUT OFF, TURN OFF THE MANUAL GAS SHUTOFF VALVE EXTERNAL TO THE FURNACE BEFORE TURNING OFF THE ELECTRICAL SUPPLY. WARNING T O PREVENT PERSONAL INJURY OR DEATH DUE TO IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR ...
5 IO-247C 10/05 WARNING T HIS PRODUCT CONTAINS OR PRODUCES A CHEMICAL OR CHEMICALS WHICH MAY CAUSE SERIOUS ILLNESS OR DEATH AND WHICH ARE KNOWN TO THE S TATE OF C ALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM. WARNING T O PREVENT POSSIBLE PROPERTY DAMAGE, PERSONAL INJURY OR DEA...