Table of Contents:
- Page 2 – Level: 2
- Page 6 – Patch file details are listed in Table 2:; Network affecting: No
- Page 7 – The debugging commands are:; Patch file details are listed in Table 3:
- Page 11 – Patch file details are listed in Table 2.
- Page 12 – The following issues have been resolved:
- Page 13 – Patch file details are listed in Table 5:
- Page 22 – DS3 Interfaces; B3ZS line encoding
- Page 24 – Loopbacks
- Page 25 – DS3 Configuration
- Page 27 – instance is the number of the DS3 interface.
- Page 29 – Dynamic Port Security
- Page 30 – Availability; licence or password is not required to use a patch.; or not
S i m p l y c o n n e c t i n g t h e w o r l d
Patch Release Note
Patch 86241-06
For Rapier Switches
Introduction
This patch release note lists the issues addressed and enhancements made in
patch 86241-06 for Software Release 2.4.1 on existing models of Rapier L3
managed switches. Patch file details are listed in Table 1.
This release note should be read in conjunction with the following documents:
■
Release Note: Software Release 2.4.1 for Rapier Switches, (Document
Number C613-10338-00 Rev A) available from
documentation/documentation.html
■
Rapier Switch Documentation Set for Software Release 2.4.1 available on
the Documentation and Tools CD-ROM packaged with your switch, or
from
www.alliedtelesyn.co.nz/documentation/documentation.html
.
WARNING: Using a patch for a different model or software release may cause
unpredictable results, including disruption to the network. Information in this
release note is subject to change without notice and does not represent a
commitment on the part of Allied Telesyn International. While every effort has
been made to ensure that the information contained within this document and
the features and changes described are accurate, Allied Telesyn International
can not accept any type of liability for errors in, or omissions arising from the
use of this information.
Some of the issues addressed in this Release Note include a level number. This
number reflects the importance of the the issue that has been resolved. For
details on level numbers, please contact your authorised distributor or reseller.
Table 1: Patch file details for Patch 86241-06.
Base Software Release File
86s-241.rez
Patch Release Date
28-Feb-2003
Compressed Patch File Name
86241-06.paz
Compressed Patch File Size
369480 bytes
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 Patch Release Note Patch 86241-05 for Software Release 2.4.1 C613-10340-00 REV E Features in 86241-06 Patch 86241-06 includes all issues resolved and enhancements released in previous patches for Software Release 2.4.1, and the following enhancements: When more than two firewall policies were conf...
6 Patch Release Note Patch 86241-05 for Software Release 2.4.1 C613-10340-00 REV E Features in 86241-05 Patch file details are listed in Table 2: Patch 86241-05 includes all issues resolved and enhancements released in previous patches for Software Release 2.4.1, and the following enhancements: Supp...
Patch 86241-06 For Rapier Switches 7 Patch 86241-05 for Software Release 2.4.1C613-10340-00 REV E Debugging commands are now available for the RADIUS and TACACS control protocols. Raw packets, decoded packets, and errors can now be displayed. Access control packet debugging allows the contents of th...