Alliance PHM802N- Manual

Alliance PHM802N

Alliance PHM802N– Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
Page: / 61

Table of Contents:

  • Page 3 – Table of; Safety Information
  • Page 4 – Explanation of Safety Messages; DANGER
  • Page 5 – NOTE: The WARNINGS and IMPORTANT
  • Page 6 – IMPORTANT: Ensure that the recommended; Safety Decals; WARNING
  • Page 7 – Operator Safety
  • Page 8 – Safe Operating Environment; Environmental Conditions
  • Page 9 – Input and Output Services; Water; AC Inverter Drive; Ensure that a ground wire from a proven
  • Page 10 – Introduction; Model Identification; Information in this manual is applicable to these
  • Page 11 – Delivery Inspection; Nameplate Location - UniLinc Models; Figure 1; Figure 1; Replacement Parts; Figure 1; MODEL EXAMPLE OF NAMEPLATE LOCATION
  • Page 12 – Figure 2; UW; Hz
  • Page 13 – Specifications and Dimensions
  • Page 17 – Machine Dimensions; Dimensional Clearances; Allow a minimum of 24 inches (60 cm) at the rear and; To avoid personal injury and/or property; Figure 3; and; Figure 4; Dim; Table 1
  • Page 20 – Figure 5; Figure 6; Di; Table 2
  • Page 23 – Dimension; Table 3
  • Page 24 – Figure 7
  • Page 25 – Figure 8
  • Page 26 – Machine Foundation Requirements; NOTE: Do not mount on wooden floors, above; CAUTION
  • Page 27 – Figure 9
  • Page 29 – Floor Load Data; Static and dynamic loads on the floor or foundation are; Specifications; Table 4
  • Page 30 – Table 5
  • Page 31 – Maximum vertical
  • Page 33 – Machine Mounting and Grouting
  • Page 34 – Mounting Bolt Hole Locations; NOTE: Mounting holes marked “A” are on; FRONT OF MACHINE
  • Page 35 – 0 VARIABLE-SPEED MODEL
  • Page 39 – Grout Placement; 5 VARIABLE-SPEED MODEL
  • Page 40 – Gap Setting for Vibration Switch; Figures; Only trained personnel should perform this
  • Page 41 – 5 Pound Model; ADJUSTMENT
  • Page 42 – ADJUSTMENT BOLT
  • Page 43 – VIBRATION SWITCH
  • Page 44 – Drain Connection Requirements; IMPORTANT: Washer-extractor must be installed; Table 6; NOTE: If a flexible connection is made directly to a; DRAIN LINE CONFIGURATION
  • Page 45 – IMPORTANT: Do not block the overflow vent; Number of drain outlets
  • Page 46 – Water Connection; Table 9; To prevent personal injury, avoid contact; Water Supply Information; Number of main fill water inlets
  • Page 47 – Water Supply Line Sizing
  • Page 48 – Electrical Installation Requirements; N, P AND R – VOLTAGE MODELS
  • Page 49 – IMPORTANT: Do NOT use fuses in place of a; MACHINES WITH ELECTRIC HEAT; MACHINES WITHOUT ELECTRIC HEAT
  • Page 51 – NOT AVAILABLE
  • Page 52 – Voltage Designation
  • Page 53 – For washer-extractors equipped with optional steam; NOTE: Failure to install the supplied steam filter; Steam Supply Information; Steam inlet connection,
  • Page 54 – Chemical Injection Supply System
  • Page 55 – Figures 5; Number of dry supply compartments
  • Page 57 – External Supplies
  • Page 59 – Remove the red jumper wire installed by the; Do not attempt to increase fuse rating or
  • Page 60 – External Supply Signals
Loading the manual

Installation

www.comlaundry.com

Washer-Extractors

Pocket Hardmount

UniLinc and M30 Control

Refer to Page 8 for Model Numbers

PHM798N

PHM802N

PHM798N

PHM802N

M30 35 – 125 Models

UniLinc 35 – 125 Models

PHM1422C

PHM1422C

UniLinc 150 Model

Part No. F8138601R11

June 2011

Keep These Instructions for Future Reference.

(If this machine changes ownership, this manual must accompany machine.)

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for Alliance PHM802N

Summary

Page 3 - Table of; Safety Information

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT © Copyright 2011, Alliance Laundry Systems LLCAll rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any means without the expressed written consent of the publisher. F8138601 1 ...

Page 4 - Explanation of Safety Messages; DANGER

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT F8138601 2 Safety Information Explanation of Safety Messages Precautionary statements (“DANGER,” “WARNING,” and “CAUTION”), followed by specific instructions, are found in this manual and on machine decals. These precautions are int...

Page 5 - NOTE: The WARNINGS and IMPORTANT

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT Safety Information 3 F8138601 11. Do not repair or replace any part of the washer, or attempt any servicing unless specifically recommended in the user-maintenance instructions or in published user-repair instructions that the user ...

Other Alliance Models