Page 2 - Enforcer 3
Page 3 - IMPORTANT INFORMATION; inaccurate and your warranty may become void.; YOU MUST WAIT AT LEAST; PARTS OF YOUR BREATHALYSER
Enforcer 3 IMPORTANT INFORMATION If you do not follow the instructions for use your test results may be inaccurate and your warranty may become void. IMPORTANT NOTE: YOU MUST WAIT AT LEAST 20 MINUTES AFTER YOUR LAST ALCOHOLIC DRINK BEFORE USING ALCOLIMIT Enforcer 3 OTHERWISE INACCURATE READINGS OF Y...
Page 4 - SPECIFICATIONS; Australia
Enforcer 3 SPECIFICATIONS Usage Personal / Professional Sensor Type Semi-conductor Alcohol Sensor with Gas Flow Sensor built-in Accuracy AS3547 Certified accuracy Calibrated to Australian & NZ legal limit Range 0.000 – 0.400g / 100mL Display LED with Backlight Usage Monitor Cumulative test count...
Page 5 - USAGE; Turning on the power; holding the button down briefly.; To operate in normal mode:
Enforcer 3 USAGE Turning on the power First, place 2xAA batteries (supplied) into your ALCOLIMIT Enforcer 3 in the correct direction as marked on the battery cover. Be sure to use high quality alkaline batteries (preferably Duracell). We recommend removing the batteries while the unit is in storage ...
Page 6 - To operate in fast mode:
Enforcer 3 Blow one consistent deep breath into the sensor. There will be a continual long beep while you are blowing. Once your ALCOLIMIT Enforcer 3 has received enough airflow you will hear a double beep signaling you to stop. If inadequate airflow is received, the word will appear on the screen. ...
Page 7 - DISPLAY & INTERPRETATION; Result Type; Negative
Enforcer 3 DISPLAY & INTERPRETATION Result Type Digital Display Negative (0.000-0.019%BAC) Caution (0.020-0.049%BAC) Positive (0.050%BAC and above) In Normal mode readings above 0.400%BAC will be displayed as 0.400%BAC. This device is a 0.050%BAC device (0.050%BAC is equal to 0.05grams of alcoho...
Page 8 - TROUBLESHOOTING GUIDE; Symptom
Enforcer 3 TROUBLESHOOTING GUIDE Symptom Solution Unit turns on and counts down then turns itself off Not enough power - replace batteries Not enough power - replace batteries Unit doesn’t power up at all Check batteries are new and in the correct direction +/- Recalibration is required Recalibratio...
Page 9 - STORAGE CONDITIONS
Enforcer 3 WARNINGS (Please read carefully) • Closed rooms with poor ventilation, pollution, smoke or air conditioning may delay the time for resetting between tests. • Not waiting at least 20 minutes after your last alcoholic drink will cause inaccurate readings, and if you continue to misuse ALCOL...
Page 10 - RECALIBRATION
Enforcer 3 RECALIBRATION The calibration period of ALCOLIMIT Enforcer is 30 days. For professional use we recommend recalibration every 1-3 months and for personal use every 3-12 months. Recalibration is required because alcohol residue builds up on the sensor and this must be cleaned because it aff...
Page 11 - Professional Recalibration Costs and Procedure:; For NZ Customers we recommend payment via Credit Card.
Enforcer 3 Professional Recalibration Costs and Procedure: Recalibration costs $45 AUD/approx. $55NZD and includes return postage to you within Australia and NZ via Australia Post Express. Post your ALCOLIMIT unit to : AlcoLimit Breathalysers Pty. Ltd. Recalibration Dept. P.O. Box 1106 Manly, N.S.W....
Page 12 - WARRANTY; DISCLAIMER
Enforcer 3 WARRANTY Manufacturer warrants for one calendar year the product to be free from defects in workmanship or materials (excluding calibration) in normal service from the date of purchase. Manufacturer’s obligation under this warranty is limited to replacing or repairing the unit if returned...
Page 16 - RECALIBRATION SERVICE RECORD; Date of
Enforcer 3 RECALIBRATION SERVICE RECORD Date of Recalibration Service Details Technician For service records to be updated, please send your instructions with your breathalyser each time it is recalibrated. Alternatively, you may request a Calibration Certificate at a cost of $22 (recommended for wo...