Page 2 - ARE I2 / RS 232 – Installation Guide; Contents; INTRODUCTION
ManualPage 2 / 33- Revision 01 ARE I2 / RS 232 – Installation Guide AEGIdentifikationssysteme GmbH Söflinger Straße 100D-89077 UlmTel. ++49(0)731-933-1340/1877Fax ++49(0)731-933-1855e-mail: [email protected] Contents 1 INTRODUCTION 5 2 SYSTEM OVERVIEW 5 3 START-UP PROCEDURE 6 4 INSTALLATION 7 4.1 Mounti...
Page 3 - OPERATING MODES OF THE READER
ManualPage 3 / 33- Revision 01 ARE I2 / RS 232 – Installation Guide AEGIdentifikationssysteme GmbH Söflinger Straße 100D-89077 UlmTel. ++49(0)731-933-1340/1877Fax ++49(0)731-933-1855e-mail: [email protected] 6.7 BD- Baudrate 19 6.8 TOR – Maximum Reading Time 20 6.9 VS- Show Parameter 20 6.10 VSAVE – Sav...
Page 5 - Introduction; System Overview; Figure 2-1: Concept of the Reading System; Transponder; Reader with
ManualPage 5 / 33- Revision 01 ARE I2 / RS 232 – Installation Guide AEGIdentifikationssysteme GmbH Söflinger Straße 100D-89077 UlmTel. ++49(0)731-933-1340/1877Fax ++49(0)731-933-1855e-mail: [email protected] 1 Introduction This document will describe the components of the Compact Reader System ARE I2 / ...
Page 7 - Installation; the housing against heavy mechanical interactions.; which in turn reduces the reading range considerably; elements without open the housing of the device.; Grounding of the Reader
ManualPage 7 / 33- Revision 01 ARE I2 / RS 232 – Installation Guide AEGIdentifikationssysteme GmbH Söflinger Straße 100D-89077 UlmTel. ++49(0)731-933-1340/1877Fax ++49(0)731-933-1855e-mail: [email protected] 4 Installation To get the specified reading performance it is necessary to do the installation c...
Page 8 - Allowed Diameter of the Used Cables
ManualPage 8 / 33- Revision 01 ARE I2 / RS 232 – Installation Guide AEGIdentifikationssysteme GmbH Söflinger Straße 100D-89077 UlmTel. ++49(0)731-933-1340/1877Fax ++49(0)731-933-1855e-mail: [email protected] Inside of the SAB Cap there are the pins of following connections: • power supply • data link to...
Page 9 - Mounting of the Power Supply Cable; The power supply cable must be mounted in following steps:
ManualPage 9 / 33- Revision 01 ARE I2 / RS 232 – Installation Guide AEGIdentifikationssysteme GmbH Söflinger Straße 100D-89077 UlmTel. ++49(0)731-933-1340/1877Fax ++49(0)731-933-1855e-mail: [email protected] 3 4 5 1 6 Cable 7 4.3.3 Mounting of the Power Supply Cable The power supply cable must be mounte...
Page 10 - Assembling of the Power Supply and Data Cable (Single Cable Pipe); be big enough to keep the voltage drop in the specified range.
ManualPage 10 / 33- Revision 01 ARE I2 / RS 232 – Installation Guide AEGIdentifikationssysteme GmbH Söflinger Straße 100D-89077 UlmTel. ++49(0)731-933-1340/1877Fax ++49(0)731-933-1855e-mail: [email protected] 4.3.4 Assembling of the Power Supply and Data Cable (Single Cable Pipe) The connection of the c...
Page 11 - Final Assembly of the Cable Pipe; Fasten the SAB Cab with the help of the screws.
ManualPage 11 / 33- Revision 01 ARE I2 / RS 232 – Installation Guide AEGIdentifikationssysteme GmbH Söflinger Straße 100D-89077 UlmTel. ++49(0)731-933-1340/1877Fax ++49(0)731-933-1855e-mail: [email protected] 4.3.5 Final Assembly of the Cable Pipe • Pull by and by all the cable back, until the isolation...
Page 12 - Com Data Port of an PC, the reader is ready to work.
ManualPage 12 / 33- Revision 01 ARE I2 / RS 232 – Installation Guide AEGIdentifikationssysteme GmbH Söflinger Straße 100D-89077 UlmTel. ++49(0)731-933-1340/1877Fax ++49(0)731-933-1855e-mail: [email protected] 4.3.7 Using the Service Cable ID 70213 Using the Service Cable, no special assembly work inside...
Page 13 - Using the Power Supply and Data Cable ID 70212; of Serial Data Port, the reader is ready to work.; Power Supply
ManualPage 13 / 33- Revision 01 ARE I2 / RS 232 – Installation Guide AEGIdentifikationssysteme GmbH Söflinger Straße 100D-89077 UlmTel. ++49(0)731-933-1340/1877Fax ++49(0)731-933-1855e-mail: [email protected] 4.3.8 Using the Power Supply and Data Cable ID 70212 Using the Power Supply and Data Cable, no ...
Page 14 - Visual Signal Lamps; To show the operational state or results there are 5 LED at the
ManualPage 14 / 33- Revision 01 ARE I2 / RS 232 – Installation Guide AEGIdentifikationssysteme GmbH Söflinger Straße 100D-89077 UlmTel. ++49(0)731-933-1340/1877Fax ++49(0)731-933-1855e-mail: [email protected] BFH ID Moderne elektronische Objekterkennung und Verfolgung L 1 L2 L4 L3 L5 ARE I2 5 Visual Sig...
Page 15 - Settings of the Reader / Most Important Parameters; default value; General
ManualPage 15 / 33- Revision 01 ARE I2 / RS 232 – Installation Guide AEGIdentifikationssysteme GmbH Söflinger Straße 100D-89077 UlmTel. ++49(0)731-933-1340/1877Fax ++49(0)731-933-1855e-mail: [email protected] 6 Settings of the Reader / Most Important Parameters The default value of the operating mode pa...
Page 16 - code; Error Codes; only the first; of in succession identical transponder numbers is output on the
ManualPage 16 / 33- Revision 01 ARE I2 / RS 232 – Installation Guide AEGIdentifikationssysteme GmbH Söflinger Straße 100D-89077 UlmTel. ++49(0)731-933-1340/1877Fax ++49(0)731-933-1855e-mail: [email protected] After entering a valid command together with a parameter value, the system answers by sending t...
Page 17 - suppression of repeatedly read IDs; CN – Suppression of No Reads; suppress NoReads on interface; NID- Failure Protection; readings have to show the same transponder number.
ManualPage 17 / 33- Revision 01 ARE I2 / RS 232 – Installation Guide AEGIdentifikationssysteme GmbH Söflinger Straße 100D-89077 UlmTel. ++49(0)731-933-1340/1877Fax ++49(0)731-933-1855e-mail: [email protected] Input format: CID <SP> parameter <CR> Parameter: Value Function 0 no filter functio...
Page 18 - Table 6-: example for the effect of the CID function
ManualPage 18 / 33- Revision 01 ARE I2 / RS 232 – Installation Guide AEGIdentifikationssysteme GmbH Söflinger Straße 100D-89077 UlmTel. ++49(0)731-933-1340/1877Fax ++49(0)731-933-1855e-mail: [email protected] 0 one out of one (no effect) 1 two out of two ; (default value) Output (example): 1 <CR> ...
Page 19 - The command EC changes of the echo function setting.; Function
ManualPage 19 / 33- Revision 01 ARE I2 / RS 232 – Installation Guide AEGIdentifikationssysteme GmbH Söflinger Straße 100D-89077 UlmTel. ++49(0)731-933-1340/1877Fax ++49(0)731-933-1855e-mail: [email protected] 6.6 EC- Echo The command EC changes of the echo function setting. Input format: EC <SP> p...
Page 20 - TOR – Maximum Reading Time; limits the reading process duration to exactly one reading cycle; VSAVE – Save Parameter
ManualPage 20 / 33- Revision 01 ARE I2 / RS 232 – Installation Guide AEGIdentifikationssysteme GmbH Söflinger Straße 100D-89077 UlmTel. ++49(0)731-933-1340/1877Fax ++49(0)731-933-1855e-mail: [email protected] 6.8 TOR – Maximum Reading Time Timeout for the reader. TOR is used in operation mode 2 as maxim...
Page 21 - Operating Modes of the Reader
ManualPage 21 / 33- Revision 01 ARE I2 / RS 232 – Installation Guide AEGIdentifikationssysteme GmbH Söflinger Straße 100D-89077 UlmTel. ++49(0)731-933-1340/1877Fax ++49(0)731-933-1855e-mail: [email protected] 7 Operating Modes of the Reader There are two operational modes defined: • Mode 2 The reading p...
Page 22 - Please note; Settings of the Reader / Most Used Parameters; TOR XYZ
ManualPage 22 / 33- Revision 01 ARE I2 / RS 232 – Installation Guide AEGIdentifikationssysteme GmbH Söflinger Straße 100D-89077 UlmTel. ++49(0)731-933-1340/1877Fax ++49(0)731-933-1855e-mail: [email protected] Figure 7.1.2 : Software triggered reading operation with TOR>0 Please note : The TOR paramet...
Page 23 - Basic Data Exchange Process; ess or an failure code is sent back to the master.; Standard Read Process / Serial Number of the Transponder GT; The reading result may also been judged according the LED’s.
ManualPage 23 / 33- Revision 01 ARE I2 / RS 232 – Installation Guide AEGIdentifikationssysteme GmbH Söflinger Straße 100D-89077 UlmTel. ++49(0)731-933-1340/1877Fax ++49(0)731-933-1855e-mail: [email protected] 7.1.2 Basic Data Exchange Process The master has to send an software command to start an read o...
Page 24 - Selective Read RD; Example; RD; Writing Process WD
ManualPage 24 / 33- Revision 01 ARE I2 / RS 232 – Installation Guide AEGIdentifikationssysteme GmbH Söflinger Straße 100D-89077 UlmTel. ++49(0)731-933-1340/1877Fax ++49(0)731-933-1855e-mail: [email protected] 7.1.4.2 Selective Read RD • Start the reader with the command RD plus Parameters ( plus <CR&...
Page 26 - Operating Mode 0 - Continuous Reading; are initiated periodically.; continuos read
ManualPage 26 / 33- Revision 01 ARE I2 / RS 232 – Installation Guide AEGIdentifikationssysteme GmbH Söflinger Straße 100D-89077 UlmTel. ++49(0)731-933-1340/1877Fax ++49(0)731-933-1855e-mail: [email protected] 7.2 Operating Mode 0 - Continuous Reading When operating continuously the exciter is switched o...
Page 27 - failure protection. selection guide 2 out 2 transponder codes
ManualPage 27 / 33- Revision 01 ARE I2 / RS 232 – Installation Guide AEGIdentifikationssysteme GmbH Söflinger Straße 100D-89077 UlmTel. ++49(0)731-933-1340/1877Fax ++49(0)731-933-1855e-mail: [email protected] • NID 1 failure protection.; selection guide 2 out 2 transponder codes The result of the readin...
Page 28 - Instructions; General Instructions; circuit, which in turn reduces the reading range considerably!
ManualPage 28 / 33- Revision 01 ARE I2 / RS 232 – Installation Guide AEGIdentifikationssysteme GmbH Söflinger Straße 100D-89077 UlmTel. ++49(0)731-933-1340/1877Fax ++49(0)731-933-1855e-mail: [email protected] 8 Instructions 8.1 General Instructions To avoid any reduction of the reading distance of the r...
Page 29 - Special Instructions for Using a Read / Write System; interference must be determined for each application itself.
ManualPage 29 / 33- Revision 01 ARE I2 / RS 232 – Installation Guide AEGIdentifikationssysteme GmbH Söflinger Straße 100D-89077 UlmTel. ++49(0)731-933-1340/1877Fax ++49(0)731-933-1855e-mail: [email protected] 8.2 Special Instructions for Using a Read / Write System To transfer the data to the transponde...
Page 30 - Hotline; If there are questions or suggestions please be so free an phone:; Reference Documentation; Edition Nr
ManualPage 30 / 33- Revision 01 ARE I2 / RS 232 – Installation Guide AEGIdentifikationssysteme GmbH Söflinger Straße 100D-89077 UlmTel. ++49(0)731-933-1340/1877Fax ++49(0)731-933-1855e-mail: [email protected] 9 Hotline If there are questions or suggestions please be so free an phone: Fax: ++49 (0)731-93...
Page 31 - Appendix
ManualPage 31 / 33- Revision 01 ARE I2 / RS 232 – Installation Guide AEGIdentifikationssysteme GmbH Söflinger Straße 100D-89077 UlmTel. ++49(0)731-933-1340/1877Fax ++49(0)731-933-1855e-mail: [email protected] 12 Appendix 12.1 Best Orientation for an F-Type -Reader Compact Reader ARE I2 Internal Antenna ...
Page 33 - Assembling of the SAB Cab
ManualPage 33 / 33- Revision 01 ARE I2 / RS 232 – Installation Guide AEGIdentifikationssysteme GmbH Söflinger Straße 100D-89077 UlmTel. ++49(0)731-933-1340/1877Fax ++49(0)731-933-1855e-mail: [email protected] 12.3 Assembling of the SAB Cab