AEG 80 / 120 kVA- Installation Manual

AEG 80 / 120 kVA

AEG 80 / 120 kVA– Installation Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
Page: / 70

Table of Contents:

  • Page 5 – Safety Instructions; Read the manual before operating or working on the UPS.; • EMC Directive
  • Page 6 – User precautions; Use of the LCD control panel and Maintenance Bypass Switch (MBS)
  • Page 7 – Introduction; System description
  • Page 8 – • No Resonance with power factor correction capacitors; technology
  • Page 9 – Basic system configuration; – UPS cabinet
  • Page 10 – UPS installation; Planning installation; conductive contaminants.
  • Page 11 – Unpacking and visual inspection; Unfasten front door latch and swing door open.
  • Page 12 – Figure 4; The UPS is delivered with the following items:; Plastic bag containing:
  • Page 13 – UPS cabinet installation; Unfasten front door latch and swing doors open.; Figure 5
  • Page 14 – Warning
  • Page 15 – Electrical installation; Procedure for locating the terminals; If not already open, unfasten front door latch and swing door open.
  • Page 16 – UPS wiring procedure; The proper connection order is as follows:
  • Page 19 – Table 2; Installing ferrite clip for battery breaker; Battery cabinets
  • Page 21 – Integral battery cabinet installation procedure
  • Page 22 – cabinet using M4 screws.
  • Page 23 – Integral battery cabinet electrical connections
  • Page 25 – Repeat Step 6 for each battery cabinet, and then proceed to Step 8.; Separate battery cabinet Installation
  • Page 26 – bottom side of the adjacent lower hinges on the battery cabinets.; Separate Battery Cabinet Electrical Connections
  • Page 27 – Repeat Step 7 for each battery cabinet, and then proceed to Step 9.
  • Page 28 – UPS communication interface
  • Page 29 – XSlot communication; Modbus Card; Wiring installation for XSlot connections
  • Page 30 – The procedure for connecting the control cables is the following:; Input and output connections
  • Page 31 – Table 5
  • Page 32 – Reinstall conduit landing plate and install conduit.
  • Page 33 – Remote emergency power off
  • Page 34 – with the first Remote EPO.
  • Page 35 – Control Panel; Identification of the display areas
  • Page 37 – Input screen; The; Bypass screen; The; Battery screen; Output screen
  • Page 38 – Output Current Screen; displays a real-time bar graph of the output current of the UPS. The
  • Page 40 – Status Indicators; The four symbols on the left side of the control panel are; Normal
  • Page 41 – Operating instructions; Starting the UPS in Normal Mode; CONTROLS; Starting the UPS in Bypass Mode
  • Page 42 – Starting the Power Module
  • Page 43 – Transfer from Normal to Bypass Mode
  • Page 44 – Transfer from Normal to Bypass Mode with UPS
  • Page 45 – Using the LOAD OFF Pushbutton; LOAD OFF; Using the REMOTE EMERGENCY POWER OFF Switch
  • Page 46 – Press the REPO pushbutton switch.
  • Page 47 – Turn UPS from normal mode to mechanical bypass
  • Page 48 – Turn UPS from mechanical bypass to normal mode; The normal start position should be following:
  • Page 49 – Maintaining the UPS System; Important Safety Instructions; Remember that your UPS system is designed to supply power; EVEN WHEN DISCONNECTED; The UPS module interiors are unsafe until the DC power source; DO NOT ATTEMPT TO ACCESS; If you suspect that a battery string needs service, you
  • Page 50 – Performing Preventive Maintenance; Perform the following steps daily:
  • Page 51 – Advanced maintenance; You have now saved the log to file.
  • Page 53 – Wiring Parallel systems; Wall-mounted tie cabinet with MBS up to 2 UPS 40-60 kVA; System Parallel Module
  • Page 55 – Table 7; Total length of 1A + 1B
  • Page 58 – Close the door and secure with a latch.; Dimensions; Weight of the Tie cabinet is 217 kg.
  • Page 59 – XSlot Hot Sync card
  • Page 62 – 0 Recycling the used UPS or batteries; These symbols indicate on a product:
  • Page 63 – 1 Dimensional drawings
  • Page 68 – 2 Technical data; Environmental specification
  • Page 69 – System DC circuit
  • Page 70 – Standard warranty
Loading the manual

User’s and Installation Guide

UPS

40–160 kVA,

400V 50/60 Hz output

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 5 - Safety Instructions; Read the manual before operating or working on the UPS.; • EMC Directive

UPS 40 – 160 kVA, 400V 50/60 Hz output User’s and Installation Guide 1023294 Revision C 5 1 Safety Instructions The UPS operates with mains, battery or bypass power. It contains components that carry high currents and voltages. The properly installed enclosure is grounded to earth and IP20 rated aga...

Page 6 - User precautions; Use of the LCD control panel and Maintenance Bypass Switch (MBS)

UPS 40-160 kVA, 400 V 50/60 Hz output User’s and Installation Guide 1023294 Revision C 6 1.3 User precautions The only user operations permitted are:- Start up and shut down of the UPS, excluding the commissioning start-up. - Use of the LCD control panel and Maintenance Bypass Switch (MBS) - Use of ...

Page 7 - Introduction; System description

UPS 40 – 160 kVA, 400V 50/60 Hz output User’s and Installation Guide 1023294 Revision C 7 2 Introduction The product described in this manual is a transformerless Uninterruptible Power System (UPS). It is a true online, continuous duty, double conversion, static state, three-phase system, providing ...

Other AEG Models

All AEG Other