Page 1
61291021L5-5A
Section 61291021L5-5A, Issue 1
TRDDS-R
Total Reach
®
All Rate DDS Termination Unit
For Outside Plant and Customer Premise
Installation and Maintenance
Section 61291021L5-5A
Issue 1, April 1999
CLEI Code # D4OIKTU8 _ _
1. GENERAL
This practice provides installation and maintenance
procedures for the ADTRAN TRDDS-R Total Reach
®
All
Rate DDS Termination Unit. Figure 1 is an illustration of the
ADTRAN TRDDS-R Unit.
The ADTRAN TRDDS-R is a span-powered termination
unit designed to deliver data rates up to 64 kbps and provide
testing functionality. Used in combination with a Total
Reach dataport unit, the TRDDS-R converts the two-wire
Total Reach signal to the traditional four-wire DDS signal for
presentation to the customer.
NOTE
The TRDDS-R must be used with an appropriate
Total Reach dataport unit.
The
TRDDS-R is an auto-rate adaptive digital network
interface typically located at the customer premises point-of-
demarcation. The TRDDS-R will deliver a standard four-
wire DDS signal up to 18 kft beyond the TRDDS-R. Both
customer and network interfaces are equipped with outside
plant lightning protection. The customer interface is capable
of receiving signals attenuated to -45dB at the Nyquist
frequency of four-wire AMI DDS. In addition to
terminating the two-wire extended range signal, the TRDDS-
R functions as a regenerative loopback device supporting
Telco-generated testing. The TRDDS-R unit is available in
T200 mechanics, and may be optioned for 0 or –10 dB output
toward the customer. Figure 2 illustrates the Total Reach
DDS Circuit Diagram.
CONTENTS
1.
GENERAL ........................................................................... 1
2.
OPTIONS ............................................................................ 2
3.
INSTALLATION ................................................................ 2
4.
TESTING ............................................................................. 4
5.
DEPLOYMENT GUIDELINES ......................................... 6
6.
WARRANTY AND CUSTOMER SERVICE ................... 7
FIGURES
Figure 1.
ADTRAN TRDDS-R ............................................. 1
Figure 2.
Total Reach DDS Circuit Diagram ........................ 2
Figure 3.
TRDDS-R Option Switch ....................................... 2
Figure 4.
Circuit Card Pin Assignments ................................ 3
Figure 5.
Signal Loss Indication ............................................ 4
Figure 6.
Total Reach Dataport Bidirectional Loopback
Pass-Thru Mode ...................................................... 6
Figure 7.
Total Reach Dataport Bidirectional Loopback
Normal Mode .......................................................... 6
TABLES
Table 1.
Wiring Connections ................................................ 3
Table 2.
UL/CUL Telecommunications Codes .................... 3
Table 3.
Faceplate Indicators ................................................ 4
Table 4.
TRDDS-R and Total Reach Dataport Loopback
Interoperability Matrix ........................................... 4
Table 5.
Latching Loopback Sequences ............................... 5
Table 6.
Alternating Loopback Sequences ........................... 5
Table 7.
Total Reach Dataport Loopbacks ........................... 6
Table 8.
Cable Type and Temperature Loss Data
@ 13.3 kHz ............................................................. 7
Table 9.
TRDDS Insertion Loss Measurements .................. 7
Figure 1. ADTRAN TRDDS-R
Custom
Telecom
E190349
SW 1
Trademarks: Any brand names and product names included in this document are trademarks,
registered trademarks, or trade names of their respective holders.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Page 2 61291021L5-5A Section 61291021L5-5A, Issue 1 Features • Two-wire deployment • Repeaterless operation • Bridged tap tolerant • Span-powered • Auto-rate adaption on subrates, 19.2 and 56 kbps rates, including secondary channel, and 64 kbpsclear channel capability • LED indicators for Power, SYN...
Page 4 61291021L5-5A Section 61291021L5-5A, Issue 1 4. TESTINGLoopback Testing Loopback tests can be performed from the CO to verifyproper loop and TRDDS-R operation. The TRDDS-Rfeatures auto-detection capability to determine the model ofTotal Reach dataport installed in the central office. Thisfeat...
Page 5 61291021L5-5A Section 61291021L5-5A, Issue 1 Initiating OCU Latching Loopback to Loop theTRDDS-R (US West Only) • SW1-6 on the TRDDS-DP must be ON to enablelatching loopback response. • From a test system or set, send an OCU latchingloopback sequence. • Send a selected test pattern and test f...