ADTRAN SLC-5 U-BR1TE III - Manual
ADTRAN SLC-5 U-BR1TE III – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Features
- Page 3 – Warranty and Customer; N O T E; • A U-BR1TE III provisioned as 2B+D cannot be; Table 1; lists the options to set for the U-BR1TE III.; Examples; II; Table 1. SLC-2000 CIT Provisioning Options; BRI = Basic Rate Interface
- Page 4 – See Figure 1; Figure 4; for SW1 and SW2 location.; Table 2; Figure 4. SW1 and SW2 Labeling
- Page 5 – Table 2. Internal Switch Option Settings
- Page 6 – Figure 5; displays the position switch settings at ISDN
- Page 7 – Figure 6; displays the position switch settings at
- Page 8 – lists the loopback options.; Table 4; Rotate the address select knob in the direction; Table 3. Rotary Switch Legend
- Page 9 – Local Loopback
- Page 10 – eoc
- Page 11 – Figure 7; Figure 8; for an illustration of the
- Page 12 – . This allows data to be sent
- Page 13 – IDSL/DDS Trouble Code; document; ADTRAN Sales
Section 61102040L4-5, Issue 2
61102040L4-5B
1
1. GENERAL
This practice provides installation and maintenance
information for the ADTRAN
SLC-5 U-BR1TE III w/
PWR and DDS Loopbacks (U-BR1TE III).
Figure 1
is an illustration of the unit. The 1102040L4 is a
direct replacement and fully compatible with the
previous ADTRAN SLC-5 U-BR1TEs, including the
1100040L1, 1100040L3, 1102040L2, and the
1102040L1.
ISDN/DDS
The U-BR1TE III employs features for both ISDN and
DDS transport. ISDN comprises the major
functionality and is described in this section.
A description of DDS functionality is located in
Section 3.
Revision History
This document has been revised to correct switch
SW1-5 function described in Table 2.
Section 61102040L4-5B
Issue 2, January 2001
CLEI Code #5SC597IF_ _
SLC-5 U-BR1TE III w/PWR and DDS Loopbacks
ISDN 2B1Q Interface
Installation and Maintenance
Functional Description
The U-BR1TE III is a channel unit for use in the
AT&T
®
SLC Series 5 and Series 2000 Digital Loop
Carrier Systems. The SLC-5 U-BR1TE III w/PWR
and DDS Loopbacks combines the functionality of a
standard SLC-5 U-BR1TE III and a U-Repeater
Powering Module which will simplify the installation
of the U-Repeater when deployed from a Digital Loop
Carrier (DLC) facility. Span powering also allows
deployment of 2-wire DDS when an IDSL OCU-R is
used to terminate the ISDN local loop. This eliminates
the need to provide AC power at the customer premises.
The U-BR1TE III can be used in SLC-5 Central
Office Terminal (COT) deployed as Feature Package
C (FPC), and SLC-5 Remote Terminals (RT)
deployed as Feature Package C without Autocut
(FPC/AC) and Feature Package B. The U-BR1TE III
will also operate in SLC-2000 COTs and RTs when
deployed as SLC Mode 1. Clear Channel capability
(B8ZS) is not required of the T1 facility if zero byte
substitution (ZBS) is enabled on the U-BR1TE III.
The U-BR1TE III plugs into a single physical slot of
the channel bank. Three time slots are required for
Figure 1. ADTRAN SLC-5 U-BR1TE III
CONTENTS
1. GENERAL .............................................................................. 1
2. INSTALLATION .................................................................... 3
3. TESTING ................................................................................ 8
4. MAINTENANCE ................................................................. 13
5. WARRANTY AND CUSTOMER SERVICE ..................... 13
FIGURES
ADTRAN SLC-5 U-BR1TE III ................................. 1
SLC-5 U-BR1TE Slot Placement Examples ............. 3
Backplane Pin Assignments ...................................... 4
SW1 and SW2 Labeling ............................................ 4
Figure 5.
Position Switch Settings at Network Locations for
ISDN Applications ..................................................... 6
SLC-5 U-BR1TE III IDSL/DDS Circuit Diagram .... 7
IDSL/DDS Loopback Response .............................. 11
ADTRAN U-BR1TE Bidirectional Loopback ........ 11
Figure 9.
IDSL/DDS Remote End Initiated Loopback, Local
Loop .......................................................................... 12
Figure 10. IDSL/DDS Remote End Initiated Loopback,
Customer Loop ......................................................... 12
Figure 11. IDSL/DDS Trouble Codes ....................................... 13
TABLES
Table 1. SLC-2000 CIT Provisioning Options ........................... 3
Table 2. Internal Switch Option Settings .................................... 5
Table 3. Rotary Switch Legend ................................................... 8
Table 4. Front Panel LED Indication .......................................... 9
UBR1TE
III
1102040L4
PWR / DDS
ACT
LP
CR
B
2
B
1
S W 1
S W 3
S W 2
Trademarks: Any brand names and product names included in this document are
t r a d e m a r k s , r e g i s t e r e d t r a d e m a r k s , o r t r a d e n a m e s o f t h e i r r e s p e c t i v e h o l d e r s .
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Section 61102040L4-5, Issue 2 61102040L4-5B 2 • Loopback release in response to TIPs generated from the network direction per TR62310. • Remap all subsequent DS0 DP loopback codes into respective eoc loopbacks to loopback respective downstream U-Repeaters, TRISDNelements, and U-BR1TES when optioned ...
Section 61102040L4-5, Issue 2 61102040L4-5B 3 C A U T I O N C A U T I O N ! SUBJECT TO ELECTROSTATIC DAMAGE OR DECREASE IN RELIABILITY. HANDLING PRECAUTIONS REQUIRED. The U-BR1TE III will function with any ISDN 2B1QU-interface that is ANSI T1.601 compliant. 2. INSTALLATION After unpacking the unit, ...
Section 61102040L4-5, Issue 2 61102040L4-5B 4 N O T E When the U-BR1TE III is optioned for B1 or B2,the SLC-2000 slot must be provisioned for Donly. If the U-BR1TE III is optioned for 2B,then the SLC-2000 slot must be provisioned forB1+D. Physical Requirements The U-BR1TE III occupies one physical s...