Page 2 - 01 Explorer Boulevard
901 Explorer Boulevard P.O. Box 140000 Huntsville, AL 35814-4000 (256) 963-8000 © 2000 ADTRAN, Inc. All Rights Reserved. Printed in U.S.A.
Page 3 - IMPORTANT SAFETY INSTRUCTIONS
61200242L1-1 NT1 ACE 4 User Manual iii IMPORTANT SAFETY INSTRUCTIONS When using your telephone equipment, basic safety pre-cautions should always be followed to reduce the risk offire, electric shock and injury to persons. The precautionsare listed below. 1. Do not use this product near water (for e...
Page 4 - AFFIDAVIT REQUIREMENTS FOR CONNECTION TO; • An affidavit is required to be given to the telephone
iv NT1 ACE 4 User Manual 61200242L1-1 AFFIDAVIT REQUIREMENTS FOR CONNECTION TO DIGITAL SERVICES • An affidavit is required to be given to the telephone company whenever digital terminal equipment with-out encoded analog content and billing protection isused to transmit digital signals containing enc...
Page 5 - AFFIDAVIT FOR CONNECTION OF CUSTOMER
61200242L1-1 NT1 ACE 4 User Manual v AFFIDAVIT FOR CONNECTION OF CUSTOMER PREMISES EQUIPMENT TO 1.544 MBPS AND/OR SUBRATE DIGITAL SERVICES For the work to be performed in the certified territory of_______________(telco name)State of ___________________County of _________________I, __________________...
Page 8 - FCC INFORMATION; Changes or modifications to this unit not ex-; Canadian Standards Association; This equipment complies with Part 68 of the FCC
viii NT1 ACE 4 User Manual 61200242L1-1 FCC INFORMATION This device complies with Part 15 of the FCC rules. Oper-ation is subject to the following two conditions: (1) Thisdevice may not cause harmful interference, and (2) thisdevice must accept any interference received, includinginterference that m...
Page 9 - If this equipment causes harm to the telephone network,
61200242L1-1 NT1 ACE 4 User Manual ix 2. If this equipment causes harm to the telephone network, the telephone company may temporarily discontinueservice. If possible, advance notification is given; oth-erwise, notification is given as soon as possible. Thetelephone company will advise the customer ...
Page 10 - The following information may be required when ap-; ISDN
x NT1 ACE 4 User Manual 61200242L1-1 7. The following information may be required when ap- plying to the local telephone company for leased linefacilities. 8. The FCC recommends that the AC outlet, to which equipment requiring AC power is to be installed, is pro-vided with an AC surge arrester. Serv...
Page 11 - CANADIAN EMISSIONS REQUIREMENTS
61200242L1-1 NT1 ACE 4 User Manual xi CANADIAN EMISSIONS REQUIREMENTS This digital apparatus does not exceed the Class B limitsfor radio noise emissions from digital apparatus as setout in the interference-causing equipment standard enti-tled "Digital Apparatus," ICES-003 of the Department o...
Page 13 - WARRANTY AND CUSTOMER SERVICE
61200242L1-1 NT1 ACE 4 User Manual xiii WARRANTY AND CUSTOMER SERVICE ADTRAN will repair or replace this product within fiveyears from the date of shipment if it does not meet its pub-lished specifications or fails while in service. For detailedwarranty, repair, and return information, refer to the ...
Page 15 - Table of Contents
61200242L1-1 NT1 ACE 4 User Manual xv Table of Contents Unit Overview .............................................................................. 1LED Indicators ............................................................................. 2Inspection ................................................
Page 16 - Figures
xvi NT1 ACE 4 User Manual 61200242L1-1 Table of Contents Figures Figure 1-1. ADTRAN NT1 ACE 4 ............................................... 1 Figure 1-2. Interface Connectors ................................................. 1Figure 1-3. Network Connector (RJ-45)......................................
Page 17 - Unit Overview; The ADTRAN NT1 ACE
61200242L1-1 NT1 ACE 4 User Manual 1 NT1 ACE 4 User Manual Unit Overview The ADTRAN NT1 ACE 4 provides up to four basic rate interfaces between customer ISDN terminal equipment (S/T)and the basic rate ISDN network (U). Figure 1-1 is an illus-tration of the NT1 ACE 4 . Figure 1-1. ADTRAN NT1 ACE 4 Fi...
Page 18 - LED Indicators; . There is a READY and; indicator for each port of the NT1 ACE
NT1 ACE 4 User Manual 2 NT1 ACE 4 User Manual 61200242L1-1 The U interface complies with ANSI T1.601 and ITU-T1.430 Recommendation Standard. The S/T interface com-plies with ANSI T1.605 and ETSI ETS 300012 Standard. The ADTRAN NT1 ACE 4 is a stand-alone unit and is pow- ered by an external power sup...
Page 19 - Inspection; After unpacking the NT1 ACE; Maintenance; The NT1 ACE; Remote Testing
61200242L1-1 NT1 ACE 4 User Manual 3 NT1 ACE 4 User Manual If an ERROR indicator is not illuminated and the READYindicator is flashing, a network test is in progress. Networkcommand tests cause a faster 8 Hz flash rate. Inspection After unpacking the NT1 ACE 4 , carefully inspect it for ship- ping d...
Page 20 - Connections; Table 1-2. Network Connector Pin Assignments; Pin
NT1 ACE 4 User Manual 4 NT1 ACE 4 User Manual 61200242L1-1 Customer and Product Service (CAPS) Department at theaddress listed in the back of this manual. Connections The NT1 ACE 4 is optioned for standard 100 ohm termina- tion. Tables 1-2 and 1-3 give the connector pin assignments,and Figures 1-3 a...
Page 21 - Table 1-3. Local Bus Connector Pin Assignments; No connection
61200242L1-1 NT1 ACE 4 User Manual 5 NT1 ACE 4 User Manual Table 1-3. Local Bus Connector Pin Assignments Figure 1-4. Local Bus Connector (RJ-45) Pin Description 1 No connection 2 No connection 3 S/T interface Receive Power Source 1 (Negative) 4 S/T interface Transmit Power Source 1 (Positive) 5 S/T...
Page 22 - Powering with the NT1 ACE; POWER
NT1 ACE 4 User Manual 6 NT1 ACE 4 User Manual 61200242L1-1 Powering with the NT1 ACE 4 Power Supply The ADTRAN NT1 ACE 4 Power Supply, part number 336012VUR01, provides power to the NT1 ACE 4 . To connect the NT1 ACE 4 to the external power supply, perform the fol- lowing steps (see Figure 1-5). 1. ...
Page 23 - Connecting the Terminal Equipment; After successfully powering up the NT1 ACE; Typical Configuration; TERMINATION is set to 100 ohms.
61200242L1-1 NT1 ACE 4 User Manual 7 NT1 ACE 4 User Manual Connecting the Terminal Equipment After successfully powering up the NT1 ACE 4 , the ERROR indicators should be on and the READY indicators shouldbe flashing. Make sure that terminal equipment (TE) isproperly terminated. Plug the TE into one...
Page 24 - Troubleshooting; If your NT1 ACE; Symptom
NT1 ACE 4 User Manual 8 NT1 ACE 4 User Manual 61200242L1-1 Figure 1-6. Typical Configuration Troubleshooting If your NT1 ACE 4 does not operate properly, please check the lists of symptoms and solutions below. For further assis-tance, please contact ADTRAN Technical Support at 888- 4ADTRAN. Symptom ...
Page 26 - Specifications; Faceplate Indicators; ready; Network Compatibility
NT1 ACE 4 User Manual 10 NT1 ACE 4 User Manual 61200242L1-1 Specifications Network Interface (U) Line ...............................2-Wire (Tip and Ring)Operating Mode ............Full-DuplexData Rate ......................160 kbps total, 144 kbps to customerSignal Format ................2B1QOutput...
Page 27 - Mechanical
61200242L1-1 NT1 ACE 4 User Manual 11 NT1 ACE 4 User Manual Mechanical Size ...............................9.0" wide, 6.375" deep, 1.625" highWeight ...........................1.5 lbsMounting .......................Wall or desktop Power 12 VDC..........................3.3 W dissipation E...
Page 29 - Technical Support and Warranty Information; Presales Inquiries and Applications Support
Technical Support and Warranty Information Presales Inquiries and Applications Support Please contact your local distributor, ADTRAN Applications Engineering, or ADTRAN Sales: Applications Engineering (800) 615-1176 Sales (800) 827-0807 Post-Sale Support Please contact your local distributor first. ...