Page 4 - Adtron I35MB Operations Manual; Introduction; I35MB Features
Adtron I35MB Operations Manual Rev. 003, PN: 610200094 1 Introduction The Adtron™ Diskpak™ Model I35MB with Adtron ActiveRAID™ technology incorporates RAID-1 mirroring in a 3.5-inch hard disk form factor. RAID-1 mirroring between two hard disk drives provides data redundancy and rebuild independent ...
Page 5 - Related Documents; Static Sensitive; – The I35MB is a static sensitive device. While setting; I35MB Jumper Settings; The following figure shows the jumper location on the I35MB:
Adtron I35MB Operations Manual Rev. 003, PN: 610200094 2 Related Documents • ANSI NCITS 340-2000 ATA/ATAPI-5 Specification • I35MB Product Specification • I35MB Installation Manual Static Sensitive – The I35MB is a static sensitive device. While setting jumpers, take precautions to ensure that stati...
Page 6 - Setting Master/Slave and Cable Select; Master Setting; Setting a Remote-Mounted Activity LED
Adtron I35MB Operations Manual Rev. 003, PN: 610200094 3 Setting Master/Slave and Cable Select This IDE jumper is only for the configuration of master, slave, cable select and to mount a remote Activity LED. Figure 3 shows the pins of the IDE jumper on the I35MB. 1 3 4 2 5 6 1 3 4 2 5 6 1 3 4 2 5 6 ...
Page 7 - Interface Connectors; I35MB Installation; DO NOT; Refer to Figure 6 on page 5 for mounting hole locations.; - The I35MB is a static sensitive device. When installing
Adtron I35MB Operations Manual Rev. 003, PN: 610200094 4 Interface Connectors The I35MB has an interface connector located on the front panel. Using an 80-conductor cable (40-pin connector); connect the I35MB to the primary or secondary ports on the IDE controller. Plug a power cable from the comput...
Page 8 - Inserting the I35MB
Adtron I35MB Operations Manual Rev. 003, PN: 610200094 5 Inserting the I35MB To install the I35MB in the hard disk drive bay: 1. Power down the computer and remove the cover. 2. Make sure that you are properly grounded. 3. Set the master/slave to desired configurations. By default, the I35MB is set ...
Page 9 - Removing the I35MB; Basic Operation; Partitioning and Formatting
Adtron I35MB Operations Manual Rev. 003, PN: 610200094 6 Removing the I35MB To remove the I35MB from the hard disk drive bay: 1. Make sure that you are properly grounded. 2. Power down the computer. 3. Remove the chassis casing. 4. Disconnect the 80-conductor cable and the computer power supply cabl...
Page 10 - I35MB LEDs and Mirror Control Buttons
Adtron I35MB Operations Manual Rev. 003, PN: 610200094 7 I35MB LEDs and Mirror Control Buttons D14 D13 D12 D11 D10 Activity LED Bank 0 Access LED Bank 0 Fault LED Bank 1 Access LED Bank 1 Fault LED S4 Buzzer Reset S2 Bank 0 Mirror Control S3 Bank 1 Mirror Control Figure 7 LEDs and Mirror controls Th...
Page 11 - Mirror Control Button Functions; Bank 0 Mirror control; release until after 20 seconds to save; Advanced Operations; Managing Faults
Adtron I35MB Operations Manual Rev. 003, PN: 610200094 8 Mirror Control Button Functions The following figure shows the location of the mirror control buttons and LEDs on the I35MB. Bank 0 Mirror control Bank 1 Mirror control Buzzer Reset Figure 8 Mirror Control Button operations The following table...
Page 12 - Bank Hard Faults; Turning the Buzzer Off; Bank Soft Faults; Rebuilding a Bank
Adtron I35MB Operations Manual Rev. 003, PN: 610200094 9 Adtron recommends having a system back-up available prior to managing hard or soft faults. Bank Hard Faults Hard fault errors may originate from any one of the following: • Write errors • Track 0 Not Found read error • HDD Timeout after a comm...
Page 13 - Changing Media; Depress the Buzzer Reset button, labeled S4 in Figure 7 on page 7.; - The I35MB is a static sensitive device. Take
Adtron I35MB Operations Manual Rev. 003, PN: 610200094 10 Rebuilding the faulted drive may take several hours, depending on the size of the media and may result in a hard fault if the drive cannot “map” around any “bad” sectors. While rebuilding can result in a reliable storage device and workable d...
Page 14 - Power down the computer.; Slide the drive out of its carrier.
Adtron I35MB Operations Manual Rev. 003, PN: 610200094 11 3. Note the bank number, 0 or 1, with the fault LED turned solid orange. This is the bank that requires attention. 4. Power down the computer. 5. Remove the computer cover and locate the I35MB in the disk drive bay. 6. Disconnect the power su...
Page 15 - Inserting the; Resetting Mirroring Indicators; Rebuilding a
Adtron I35MB Operations Manual Rev. 003, PN: 610200094 12 12. Before the disk drive is fully seated (approximately ¼ of an inch to the drive being fully seated) re-attach the flex cable to the disk drive. Refer to Figure 10 for a view of this procedure. Carefully align and slowly attach. Pay close a...
Page 16 - Rebuilding a bank
Adtron I35MB Operations Manual Rev. 003, PN: 610200094 13 Rebuilding a bank After a bank has been replaced, a rebuild must be performed. To start a Bank Rebuild, press the mirror control button between 5 and 10 seconds on the off-line bank. Release the button when the Access LED starts flashing at 2...
Page 17 - Aborting a button press
Adtron I35MB Operations Manual Rev. 003, PN: 610200094 14 Examples: A new I35MB is installed in the field with two 20GB capacity media for 20GB of mirrored storage. Bank 1 requires replacement. A 10GB media is installed and the button pressed for rebuild. Rebuild will not start and the mirror remain...
Page 18 - Using the I35MB Rail Kit; Using Different Size Media; for; Changing; connecting the hard disk drive.
Adtron I35MB Operations Manual Rev. 003, PN: 610200094 15 Using the I35MB Rail Kit The following steps describe the process to disassemble and reassemble hard disk drives on the I35MB. Attention to individual instructions is necessary to ensure functionality and avoid damage to the device. Please co...
Page 19 - The I35MB incoporates:
Adtron I35MB Operations Manual Rev. 003, PN: 610200094 16 S.M.A.R.T. (Self-Monitoring, Analysis and Reporting Technology) Attributes The Adtron Diskpak I35MB incorporates an array of S.M.A.R.T. attributes and capabilities that provide significant amounts of information relating to the life history o...
Page 21 - Temperature Degrees; The DMA error counter is reset to zero with any hard reset.
Adtron I35MB Operations Manual Rev. 003, PN: 610200094 18 Attribute Number (8 bits) Name Value (8 bits) Raw Data (eight, 8-bit bytes) Threshold 194 (0xC2) Temperature Degrees C (Note 194) 0 199 (0xC7) (Note 199) UltraDMA error count 0 Unsigned integer 0 Table 3 S.M.A.R.T. Attributes S.M.A.R.T Attrib...
Page 22 - LED Indicators; IDLE State – No host access
Adtron I35MB Operations Manual Rev. 003, PN: 610200094 19 LED Indicators IDLE State – No host access Bank State Bank Access LED(Green/Orange) Bank Fault LED (Green/Orange) Drive Activity LED (Green/Orange) Description Normal GREEN OFF GREEN No host access Request off-line GREEN flashing (1/sec) OFF ...
Page 23 - ACTIVE State – Host access
Adtron I35MB Operations Manual Rev. 003, PN: 610200094 20 ACTIVE State – Host access Bank State Bank Access LED(Green/Orange) Bank Fault LED (Green/Orange) Drive Activity LED (Green/Orange) Description Normal GREEN OFF ORANGE Host access in progress (reads or writes) Request off-line GREEN flashing ...
Page 24 - I35MB Dimension Drawings
Adtron I35MB Operations Manual Rev. 003, PN: 610200094 21 I35MB Dimension Drawings 25.3 .997 6-32 x 3.8[.150] MAX. DEPTH (3X) 101.6 4.000 5.750 146.1 Figure 11 I35MB
Page 25 - Appendix I; Using the; Rail – Left
Adtron I35MB Operations Manual Rev. 003, PN: 610200094 22 Appendix I The table below lists the parts supplied on the I35MB Rail Kit. Items numbers correspond with Figure 11, under the section of this document titled, Using the I35MB Rail Kit . Item Number Quantity Description # 1 Four (4) Rail Reten...
Page 26 - Sales and Technical Support; Standard Warranty
Adtron I35MB Operations Manual Rev. 003, PN: 610200094 23 Sales and Technical Support Contact Adtron Corporation for technical support, application questions, data sheets, and documentation. Our normal business hours are Monday through Friday, 8am to 5pm, MST. Headquarters – Sales Europe - Sales Adt...
Page 27 - Revision Control
Adtron I35MB Operations Manual Rev. 003, PN: 610200094 24 Revision Control Rev Author Date Sections Description 001 JMH Apr 2005 All Original 002 JMH Aug 2005 Connector 8-pin change to the connector 003 JMH Mar 2006 SMART, Rail Kit Adding SMART attributes/ and information. Rail Kit guide.