ADC 450428 - Manual

ADC 450428

ADC 450428 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
Page: / 62

Table of Contents:

  • Page 2 – Retain This Manual In A Safe Place For Future Reference; Important; “IMPORTANT NOTE TO PURCHASER”; FOR YOUR SAFETY
  • Page 3 – IMPORTANT; Safety and Health Administration); CHILDREN SHOULD NOT BE ALLOWED TO PLAY ON OR NEAR THE DRYER(S).; CHILDREN SHOULD BE SUPERVISED IF NEAR DRYERS IN OPERATION.; DRYERS SHOULD NEVER BE LEFT UNATTENDED WHILE IN OPERATION.; CAUTION; DO NOT; DO NOT; USE DRYER IN THE PRESENCE OF DRY CLEANING FUMES.; WARNING
  • Page 4 – Dryers; must not
  • Page 5 – Table of Content
  • Page 7 – SECTION I; IMPORTANT INFORMATION; A. SAFETY PRECAUTIONS; For your safety, the information in this manual; service panels removed. PERSONAL INJURY or FIRE COULD RESULT.; ALL
  • Page 8 – Failure to do so will VOID THE WARRANTY.; WARNING: PERSONAL INJURY or FIRE COULD RESULT.; WARNING: YOU MUST DISCONNECT and LOCKOUT THE ELECTRIC SUPPLY and; (Occupational Safety and Health Administration)
  • Page 9 – SECTION II; ROUTINE MAINTENANCE; should be; WARNING: LINT FROM MOST FABRICS IS HIGHLY COMBUSTIBLE. THE; Frequency can best be determined at each location.
  • Page 10 – WARNING: THE ACCUMULATION OF LINT IN THE EXHAUST DUCT WORK CAN; OBSTRUCT THE FLOW OF COMBUSTION and VENTILATION AIR.
  • Page 11 – SECTION III; INSTALLATION REQUIREMENTS; must be; CAUTION: IMPROPERLY SIZED or INSTALLED EXHAUST DUCT WORK CAN; B. ELECTRICAL and GAS REQUIREMENTS
  • Page 12 – Any burner changes; C. OPERATIONAL SERVICE CHECK PROCEDURE
  • Page 13 – should spin
  • Page 14 – SECTION IV; DESCRIPTION OF PARTS
  • Page 16 – and PULLEY ARRANGEMENT; The main door switch is a safety device and should
  • Page 17 – L. MANUAL RESET THERMOSTAT
  • Page 18 – N. LINT DRAWER SWITCH; should never be; O. STEAM DAMPER SYSTEM
  • Page 19 – SECTION V; SERVICING; INTRODUCTION; Observe; and while making repairs.; A. COMPUTER CONTROLS
  • Page 20 – To Replace Computer; To Replace Keyboard (Touchpad) Label Assembly
  • Page 21 – B. IGNITION CONTROLS
  • Page 22 – NOTE: DO NOT WRAP THE HOT SURFACE IGNITOR WIRES AND THE FLAME
  • Page 25 – To Replace Burner Tubes; Test; connections for leaks by brushing on a soapy water solution.; To Replace HSI (Hot Surface Ignition) Module; CIRCUMSTANCES; should heat circuit safety devices ever be
  • Page 26 – should heat safety devices be disabled.
  • Page 27 – To Replace Sail Switch; no airflow; PERSONAL INJURY or FIRE COULD RESULT.; E. FRONT PANEL and MAIN DOOR ASSEMBLIES
  • Page 28 – IMPORTANT: UNDER NO CIRCUMSTANCES; should the door switch be disabled.; To Replace Main Door Assembly; To Install New Main Door Glass
  • Page 29 – press hard or the silicone thickness between the glass and door; will; should now be; To Replace Front Panel; To Replace Main Door Hinge Block
  • Page 30 – created in the hub of the mounted sheave which; To Replace Small Idler Pulley
  • Page 31 – created in the hub of the mounted sheave which may cause it; To Replace Large Idler Pulley; will be; To Replace Motor Pulley
  • Page 33 – cannot; Never strike the shaft directly with a hammer.
  • Page 37 – To Replace Drive Motor; To Replace Impellor Motor (Fan Shaft Drive)
  • Page 39 – SECTION VI; TROUBLESHOOTING; should not be
  • Page 41 – For models with the manual reset hi-limit thermostat refer to
  • Page 43 – SECTION VII; PHASE 6 OPL SYSTEM DIAGNOSTICS; For other countries, such as Australia, the retry count; may; not
  • Page 44 – Once the Phase 6
  • Page 49 – Should be
  • Page 52 – E. COMPUTER LOGIC and WIRING DIAGRAM; When contacting; with electrical questions, please have on hand the correct wiring
  • Page 54 – No Display Condition; In this next section; voltage checks; Drive motor reverses but does not forward, blower motor runs
  • Page 55 – Blower motor does not operate, drive motor runs; Lint Door Condition
  • Page 56 – Main Door Condition
  • Page 57 – MANUAL RESET HI-LIMIT INSTRUCTIONS; FOR PHASE 6 MODELS; Discontinue power to dryer before attempting to reset hi-limit.; Discontinue power to dryer
  • Page 58 – SECTION VIII; TECHNICAL INFORMATION
  • Page 59 – Information on the Data Label
  • Page 60 – C. HOW TO USE A MANOMETER
Loading the manual

121099DMG/tcosta

ADC

Part No. 450428

ML-130

Service Manual

Phase 6 Microprocessor

Timer Controls

American Dryer Corporation

88 Currant Road

Fall River, MA 02720-4781

Telephone: (508) 678-9000 / Fax: (508) 678-9447

e-mail: [email protected]

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Retain This Manual In A Safe Place For Future Reference; Important; “IMPORTANT NOTE TO PURCHASER”; FOR YOUR SAFETY

Retain This Manual In A Safe Place For Future Reference American Dryer Corporation products embody advanced concepts in engineering, design, and safety. If this product is properly maintained, it will provide many years of safe, efficient, and trouble-free operation. ONLY qualified technicians shoul...

Page 3 - IMPORTANT; Safety and Health Administration); CHILDREN SHOULD NOT BE ALLOWED TO PLAY ON OR NEAR THE DRYER(S).; CHILDREN SHOULD BE SUPERVISED IF NEAR DRYERS IN OPERATION.; DRYERS SHOULD NEVER BE LEFT UNATTENDED WHILE IN OPERATION.; CAUTION; DO NOT; DO NOT; USE DRYER IN THE PRESENCE OF DRY CLEANING FUMES.; WARNING

IMPORTANT YOU MUST DISCONNECT and LOCKOUT THE ELECTRIC SUPPLY and THE GASSUPPLY or THE STEAM SUPPLY BEFORE ANY COVERS or GUARDS AREREMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING, ADJUST-ING, INSTALLATION, or TESTING OF ANY EQUIPMENT per OSHA (Occupational Safety and Health Administration) STA...

Page 4 - Dryers; must not

WARNING The dryer must never be operated with any of the back guards, outer tops, or servicepanels removed. PERSONAL INJURY or FIRE COULD RESULT. IMPORTANT PLEASE OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment and/orspecified in the installation and operator's manual included with the dry...