Page 3 - Document printing history
iii Copyright 1998. ADC Kentrox. All Rights Reserved. Specifications published here are current or planned as of the date of publication of this document. Because we are continuously improving and adding features to our products, ADC Kentrox reserves the right to change specifications without prio...
Page 4 - Important safety information
iv Important safety information This symbol on the product alerts the user to the presence of important operating and maintenance (servicing) instructions in the literature accom-panying the product. This equipment has been designed to the highest quality standards of materials, workmanship and safe...
Page 5 - Warranty information
v Warranty information ADC Kentrox warranties to Buyer that the products or services are free from sub-stantial defects and workmanship under normal use given proper installation and maintenance for the period of 60 months from the date of original shipment. Buyer will promptly notify ADC Kentrox of...
Page 7 - Contents
vii Contents Preface Who is this manual for? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Who to call for assistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Chapter 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 9 - Preface; Who is this manual for?
1 Preface This manual explains how to install, power up, and configure the 1010PA ISDN Network Termination Unit. Who is this manual for? This manual is for the person installing an ISDN NT1 unit. It contains everything an installer needs to know to power on the unit and confirm that it is functionin...
Page 11 - Introduction
3 C H A P T E R 1 Introduction The 1010 is a compact, versatile, and affordable Network Termination 1 (NT1) device. The 1010 is used for connecting Integrated Services Digital Network (ISDN) voice or data Terminal Equipment (TE) to the ISDN line provided by the telephone company. The NT1 is pictured...
Page 13 - Setting up your hardware; Taking inventory
5 C H A P T E R 2 Setting up your hardware Taking inventory The 1010 package contains the following items: ■ One 1010 unit ■ One RJ11 to RJ45 cable ■ One RJ45 to RJ45 cable ■ One power supply unit (AD62010) ■ One plastic wall mount bracket ■ Two jumpers ■ Two screws and two plastic anchors for wall ...
Page 15 - Installing your unit; Rear panel
7 C H A P T E R 3 Installing your unit Rear panel 1 The 1010 rear panel (see Figure 3) has three RJ45 connectors, two for the S/T-interface and one for the U-interface. 2 The two RJ45 connectors for the S/T interface, located on the left side of the rear panel, are connected in parallel internally. ...
Page 17 - Internal jumper settings
9 Internal jumper settings The 1010 is shipped with 100 Ω Termination Resistance (TR). This TR is added to the S/T bus when dip switches 1 & 2 are set to the on position. If the installed S/T bus ISDN CPE provides 100 Ω TR, dip switches 1 & 2 should be set to the off posi- tion to provide 0 ...
Page 18 - Wiring instructions
10 Wiring instructions Figure 4 shows the wiring diagram of the 1010 with the ISDN Customer Premise Equipment (CPE) and the Line Termination (LT). Follow the instructions given below to set up the 1010: Figure 4—Wiring diagram 1 Adjust the DIP switches for the desired S/T wiring setup (see Table 4)....
Page 19 - Wall mounting instructions; Power source
11 Wall mounting instructions To mount the 1010 on a wall, follow these instructions. 1 Drill two holes in the wall corresponding to the holes on the wall mount bracket provided with the 1010. 2 Insert the plastic wall anchors into the wall holes, using a hammer if neces-sary. 3 Align the bracket wi...
Page 21 - S/T bus configuration
13 C H A P T E R 4 S/T bus configuration The 1010’s dip switch settings relate to the five possible configurations of the S/T bus. The 1010 allows the user to adjust the S/T bus Termination Resistance (TR) and S/T bus timing. Figure 6—End of Passive Bus (P-P) Figure 7—Short Passive Bus (Point-to-Mul...
Page 23 - Specifications
15 C H A P T E R 5 Specifications Table 6—Specifications Parameter Specification Physical Height - 1.3"Width - 3.9"Depth - 5.7"Weight - 1.0 lb. Environment Complies with AT&T Pub. 62310. Operating temperature 0°C to 60°C (32 ° F to 140°F) Storage temperature -25 ° C to 60 ° C (-13 ° ...