Page 2 - This manual and Marks; WARNING
This manual and Marks All safety messages are identified by the following, “ WARNING ” or “ CAUTION ”, of ANSI Z535.4 (American National Standard Institute: Product Safety Signs and Labels). The meanings are as follows: WARNING A potentially hazardous situation which, if not avoided, could result in...
Page 3 - Contents
AD-4405 Weighing Indicator, Instruction Manual, A&D Co., ltd. Contents 1. Compliance ................................................................................................................................. 3 1.1.1. Compliance with FCC Rules .................................................
Page 4 - Page
Page 2 AD-4405 Weighing Indicator 9.1.1. Using Code Memory ................................................................................................ 37 10. Comparison .................................................................................................................................
Page 5 - measures are necessary to eliminate the interference.
AD-4405 Weighing Indicator Page 3 1. 1. 1. 1. Compliance Compliance Compliance Compliance 1.1.1. Compliance with FCC Rules Please note that this equipment generates, uses and can radiate radio frequency energy. This equipment has been tested and has been found to comply with the limits of a Class A ...
Page 9 - Installing an Option Board; Caution
AD-4405 Weighing Indicator Page 7 3.1.5. Installing an Option Board This is the procedure for the data output board (OP-03, OP-05, OP-07 and OP-08). Caution Do not remove any screws without the following step. Step 1 Remove the power cord from the power outlet (mains) and other cables from the indic...
Page 10 - Front Panel Description; Accumulation
Page 8 AD-4405 Weighing Indicator 4. 4. 4. 4. Description of Panels and symbols Description of Panels and symbols Description of Panels and symbols Description of Panels and symbols 4.1.1. Front Panel Description N o. Name Description 1 STABLE Indicates when the display is stable. 2 NET Indicates wh...
Page 13 - Items of Calibration Mode; Cal in
AD-4405 Weighing Indicator Page 11 5. 5. 5. 5. Calibration Calibration Calibration Calibration This indicator, converts an input voltage from a load cell to the "mass" value, and displays it. Calibration is the adjustment function so that the scale (indicator) can display the weight correctl...
Page 14 - Caloff; CAL; Calibration Procedure; Configuring a Weighing Instrument
Page 12 AD-4405 Weighing Indicator Note that the ON/OFF key does not function alone. Press the ESC key while holding the ON/OFF key to end the calibration mode, if mis-operation. After displaying Can5el , press the ON/OFF key to end the calibration mode and turn the indicator off. NOTE: When display...
Page 15 - dUal
AD-4405 Weighing Indicator Page 13 Dual Range <First range> Select the resolution, decimal point position and format. ¯ <First range> Select the weighing range ¯ <Second range> Select the resolution ¯ <Second Range> Specify the weighing capacity For the range function, refer ...
Page 16 - Cap; ENTER; To Get Stabilized Data
Page 14 AD-4405 Weighing Indicator Specifyi Specifyi Specifyi Specifying ng ng ng the Weighing Range of the First Range the Weighing Range of the First Range the Weighing Range of the First Range the Weighing Range of the First Range Step 3 After displaying Cap for 2 seconds, the first range or the ...
Page 17 - Cal 0; Cal f; To Span Calibration
AD-4405 Weighing Indicator Page 15 5.2.3. Zero Calibration Procedure Step 8 Check the Cal 0 display. Select a zero calibration method to adjust the zero point Weighing input (Normal way) The adjustment method with nothing on the weighing unit. To step 9 Digital input The numerical way to enter a loa...
Page 18 - key while the; Exiting the Calibration Mode; Calend; Turn display off
Page 16 AD-4405 Weighing Indicator Weighing a Mass less than the Maximum Capacity Step12 Set a mass value using the 0 - 9 keys. Step13 Place a mass equivalent to the displayed value on the weighing unit. Proceed to step 15. Weighing a Maximum Capacity Mass Step14 Place a mass equivalent to the maxim...
Page 19 - CanCel; Weighing Range Function
AD-4405 Weighing Indicator Page 17 ESC key ..... The key to store the parameters temporarily. Proceed to the Cal 0 display. Press and hold the ON/OFF key and press the ESC key No parameters are changed, CanCel is displayed and the calibration mode is finished. Step18 Press the ON/OFF key to turn the...
Page 20 - Setting the Division and Range; Digital Linearization Function; key while the STABLE mark is off.; MODE; lnr
Page 18 AD-4405 Weighing Indicator 5.3.1. Setting the Division and Range Consider the following rules to design the weighing range. Rule 1 Select the division and range of each weighing range so as to fit the following inequality. The first range < the second range The division of the next weighi...
Page 21 - Note
AD-4405 Weighing Indicator Page 19 5.5. 5.5. 5.5. 5.5. Gravity Compensation Function Gravity Compensation Function Gravity Compensation Function Gravity Compensation Function If the scale is used at the calibration location, it is not necessary to perform this function. If there is a difference of g...
Page 22 - The Gravity Acceleration Table
Page 20 AD-4405 Weighing Indicator 5.5.1. The Gravity Acceleration Table Amsterdam 9.813 m/s 2 Manila 9.784 m/s 2 Athens 9.800 m/s 2 Melbourne 9.800 m/s 2 Auckland NZ 9.799 m/s 2 Mexico City 9.779 m/s 2 Bangkok 9.783 m/s 2 Milan 9.806 m/s 2 Birmingham 9.813 m/s 2 New York 9.802 m/s 2 Brussels 9.811 ...
Page 23 - Exiting from a Calibration error
AD-4405 Weighing Indicator Page 21 5.6. 5.6. 5.6. 5.6. Calibration Error Cod Calibration Error Cod Calibration Error Cod Calibration Error Code List e List e List e List Exiting from a Calibration error ESC key ..... The key to return to the point where an error occurred. Retry the operation. ESC ke...
Page 24 - Changing the Function Settings; Operating Item; Type2 and Type3 are indicated in the; Exit function setting; Weighing
Page 22 AD-4405 Weighing Indicator 6. 6. 6. 6. Functions Functions Functions Functions There are two parameters lists, one for the F-functions and one for the CF-functions. These functions control the indicator. The parameters of each function are stored in non-volatile memory, and are not lost even...
Page 25 - Weighing Conditions (Digital Filter, Zero trucking and Stability); ZERO
AD-4405 Weighing Indicator Page 23 6.2. 6.2. 6.2. 6.2. F F F F- - - -Functions Functions Functions Functions Weighing Conditions (Digital Filter, Zero trucking and Stability) Item Parameter Description 0 2 d/ 1.6s 1 4 d/ 1.6s 2 8 d/ 1.6s 3 16 d/ 1.6s 4 32 d/ 1.6s 5 64 d/ 1.6s 6 128 d/ 1.6s 7 2 d/ 3....
Page 26 - Key Switch
Page 24 AD-4405 Weighing Indicator Display and Other General Functions Item Parameter Description * 0 5 times/s f04 Display update rate 1 10 times/s The selection in the unstable condition. 1 x Key click (Sound or no) 2 x LoLo / Zero band 3 x LO 4 x OK 5 x HI f05 [Type2] Buzzer 6 x HiHi / Batch fini...
Page 34 - Parameter
Page 32 AD-4405 Weighing Indicator 6.3. 6.3. 6.3. 6.3. CF CF CF CF- - - -Functions Functions Functions Functions Item Parameter Description * 0 No limitation Cf00 Zero tracking width, motion detection condition 1 Use limitation at F01, F02, F03, F27 and F28. * 0 2% of CAP, Tare limit is 100 % CAP 1 ...
Page 35 - Tare
AD-4405 Weighing Indicator Page 33 7. 7. 7. 7. Tare Tare Tare Tare The function is used to display a net value with the container weight subtracted from the total weight, if you place an object into a container to weigh it. Using a serial interface such as the RS-232C, you can do this from the exter...
Page 36 - and
Page 34 AD-4405 Weighing Indicator 8. 8. 8. 8. Accumulation Accumulation Accumulation Accumulation This function accumulates weighing data and stores the total data and the accumulation count. The data is stored in non-volatile memory, and is not lost even if the power is turned off. 8.1.1. Preparat...
Page 37 - Display and Operation; total
AD-4405 Weighing Indicator Page 35 8.1.2. Display and Operation Action of Accumulating Data When accumulating data, the display blinks once. If the accumulated data is stored, the M+ mark is displayed. Caution This function can not accumulate data with a different unit. Specify a unit before use. Di...
Page 38 - Print out of Accumulated Data; TOTAL
Page 36 AD-4405 Weighing Indicator Output of Accumulated Data Accumulated data can be output to the serial interface. Output by manual or automatic, and output data format is selected at f41 of the F-function setting. f41 Parameter Manual/Automatic Format 0 No output * 1 Manual 2 Automatic Fixed for...
Page 39 - Code; Cd
AD-4405 Weighing Indicator Page 37 9. 9. 9. 9. Code Memory Code Memory Code Memory Code Memory This indicator has four Code memories (1 through 4). Each Code memory stores a set of setpoints, preset tare and the unit weight for piece counting. The data is stored in non-volatile memory, and is not lo...
Page 40 - Changing the Code Memory Number by External Input; Comparison; Weight Check Mode
Page 38 AD-4405 Weighing Indicator Changing the Code Memory Number by External Input The code memory number can be changed by external input from OP-05 or OP-08. Set f14 and f15 to 18 . (OP-08 has only one input; set f15 ) f13 18 : Inhibit reading EXT.2 and EXT.3 to prevent unintentional reading whe...
Page 43 - that use the setpoint comparison.
AD-4405 Weighing Indicator Page 41 10.2. 10.2. 10.2. 10.2. Setpoint Comparison Setpoint Comparison Setpoint Comparison Setpoint Comparison This function includes the weighing sequence and is used for acquiring a preset target weight. There are four parameters of "Final", "Preliminary"...
Page 44 - Batch; STOP
Page 42 AD-4405 Weighing Indicator F22 = 9 (Check weighing 3:Loss in weight) F22 = 9 (Check weighing 3:Loss in weight) F22 = 9 (Check weighing 3:Loss in weight) F22 = 9 (Check weighing 3:Loss in weight) Output and Condition Output and Condition Output and Condition Output and Condition * Relay OK ou...
Page 48 - Weigh Actual Samples; SAMPLE
Page 46 AD-4405 Weighing Indicator 12. 12. 12. 12. Counting Func Counting Func Counting Func Counting Function tion tion tion This function determines the number of objects in a sample based on the unit weight. The unit weight is stored in one of the code memory data in non-volatile memory, and is n...
Page 49 - loUt
AD-4405 Weighing Indicator Page 47 ENTER key ..............The key to register the unit weight and return to the piece count display. The unit weight is calculated automatically with the weight and the number of samples. Press the ESC key while pressing +/- key The key to return to the piece count d...
Page 52 - date
Page 50 AD-4405 Weighing Indicator Step 3 After displaying the date format for 2 seconds, the present date is displayed in f51 format. The f52 parameters are effective in the setting mode. Set the date using the following keys. 0 - 9 key .......... The key to set the value at the blinking digit, the...
Page 53 - Print; Examples
AD-4405 Weighing Indicator Page 51 14. 14. 14. 14. Internal Printer (OP Internal Printer (OP Internal Printer (OP Internal Printer (OP- - - -06) 06) 06) 06) A dot matrix type printer (OP-06) can be installed in the AD-4405. It can print out the result of weighing, accumulated weight, date and time, ...
Page 58 - Specification
Page 56 AD-4405 Weighing Indicator 16. 16. 16. 16. RS RS RS RS- - - -232C Interface 232C Interface 232C Interface 232C Interface 16.1. 16.1. 16.1. 16.1. Specification Specification Specification Specifications s s s Transmission Asynchronous, bi-directional, half-duplex Baud rate 600, 1200, 2400, 48...
Page 59 - figures 3 figures; Header 1 Header 2
AD-4405 Weighing Indicator Page 57 16.2. 16.2. 16.2. 16.2. Data Format Data Format Data Format Data Format There are two data format types set at F-Function f34 and f35 . The initial data format of f34 is shown below. Header 1 f34 , 35 : 9 (Status) ST Stable weight data. US Unstable weight data. OL ...
Page 60 - Explanation of Command
Page 58 AD-4405 Weighing Indicator 16.3. 16.3. 16.3. 16.3. Command Format Command Format Command Format Command Format Explanation of Command Explanation of Command Explanation of Command Explanation of Commands s s s When performing a command, the received command or replay data is sent back. When ...
Page 66 - UFC Command Parameter
Page 64 AD-4405 Weighing Indicator 16.4. 16.4. 16.4. 16.4. UFC Command UFC Command UFC Command UFC Commands s s s UFC (Universal Flexi Coms) function enables editing the serial data output format or the print out format freely using the serial interface command. For customizing the print out of the ...
Page 68 - Circuit
Page 66 AD-4405 Weighing Indicator 17. 17. 17. 17. RS RS RS RS- - - -422/RS 422/RS 422/RS 422/RS- - - -485, Relay Output(OP 485, Relay Output(OP 485, Relay Output(OP 485, Relay Output(OP- - - -03 03 03 03)))) Replacing the RS-232C interface with this option, the RS-422/RS-485 interface can connect u...
Page 69 - Connection; The polarity of signals A and B may vary with different computers.; Host computer
AD-4405 Weighing Indicator Page 67 Switching Between RS Switching Between RS Switching Between RS Switching Between RS- - - -422/RS 422/RS 422/RS 422/RS- - - -485 485 485 485 Switching between RS-422/RS-485 is made with the slide switch (S1) on the OP-03 board. Connection Connection Connection Conne...
Page 70 - Control input
Page 68 AD-4405 Weighing Indicator 18. 18. 18. 18. Relay Output & Control Input (O Relay Output & Control Input (O Relay Output & Control Input (O Relay Output & Control Input (OP P P P- - - -05) 05) 05) 05) Replacing the RS-232C interface with this option, 3-relay outputs and 3-cont...
Page 71 - Note: Please confirm that the AC adapter type is correct; Remarks
AD-4405 Weighing Indicator Page 69 19. 19. 19. 19. 4 4 4 4- - - -20mA Analog Output (OP 20mA Analog Output (OP 20mA Analog Output (OP 20mA Analog Output (OP- - - -07) 07) 07) 07) The OP-07 analog output option is for sending the weight data to an analog input unit. The output is a 4mA to 20mA curren...
Page 72 - Circuits
Page 70 AD-4405 Weighing Indicator 20. 20. 20. 20. Current Loop Output (OP Current Loop Output (OP Current Loop Output (OP Current Loop Output (OP- - - -08) 08) 08) 08) Replacing the RS-232C interface with this option, current loop output, 3-relay outputs and 1-control input can be used with the RS-...
Page 76 - MEMO