Xantrex XADC - Manual

Xantrex XADC

Xantrex XADC – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
Page: / 26

Table of Contents:

  • Page 2 – About These Installation Instructions; Purpose; The purpose of these Installation Instructions is to provide; Audience; The following conventions are used in this guide.; WARNING
  • Page 3 – Important Safety Instructions; WARNING: Limitations on Use
  • Page 4 – Explosive Gas Precautions; Make sure the area around the battery is well ventilated.; WARNING: Explosion hazard
  • Page 5 – FCC Information to the User; Reorient or relocate the receiving antenna
  • Page 6 – Installation; Main Components; Figure 1 and Figure 2 show the main components of the XADC.; Figure 1; XADC External Components
  • Page 7 – AC/DC Distribution Panel; Figure 2; XADC Internal Components
  • Page 8 – Figure 3; AC/DC Distribution Panel Components; Figure 4; 0A and 50A Panel Connection Diagrams
  • Page 9 – Figure 5; AC/DC Distribution Panel and XADC Internal Components
  • Page 10 – Installation Codes
  • Page 11 – XADC converter faceplate and mounting hardware; Choosing a Location; The XADC may be mounted in 3 orientations:; Figure 6; Installation Configurations
  • Page 12 – Preparing to Install; To prepare the XADC for installation:; Mounting Flanges; Figure 8; AC and DC Wiring Compartment Removal
  • Page 13 – Preparing the Mounting Location for the XADC; To prepare the XADC mounting location:; Connecting the DC Battery; the clamping ring (but not the clamp screws) on the strain relief.; WARNING: Shock hazard
  • Page 14 – Connecting the AC Input; To connect the AC input:; Route AC wires through the AC wiring compartment hole.; Figure 9; XADC DC Connections; XADC AC Connections
  • Page 15 – Mounting the XADC; To mount the XADC using the mounting plates:; Installing XADC with the AC/DC Distribution Panel; Configurations; To prepare the panel for installation:
  • Page 16 – To prepare the XADC for remote installation:
  • Page 17 – Connecting the XADC and Panel Together; To connect the XADC and panel together:; Mounting Flanges for Installation
  • Page 18 – Preparing the Mounting Location for the XADC and Panel; To prepare the XADC and panel mounting location:; Connection Types for AC and DC; To perform connections with the screw-in type lug:; Connecting the DC to the Panel; To connect the DC loads:
  • Page 19 – DC PCB Removal
  • Page 20 – Connecting the Panel to the XADC DC Side; To connect the panel to the XADC DC side:; panel through the DC wiring compartment hole to the XADC.
  • Page 21 – Connecting the Panel to the XADC AC Side; To connect the panel to the XADC AC side:; the panel, marked “Equipment Grounding Terminal”.
  • Page 22 – Connecting the AC to the Panel; See Figure 4 on page 8 for panel electrical connection diagrams.; Install a UL/CSA approved strain relief on the AC input cables.
  • Page 23 – AC Loads; To install the AC loads:; to determine how it installs.; Mounting the XADC and Panel when Connected; To mount the XADC and panel when connected:; Slide the complete unit into the mounting cutout.
  • Page 24 – Mounting the XADC and Panel Remotely; To mount the XADC and panel remotely:; this may cause stripping of the screw threads).; DC Wire Size and Torque Values; Table 1; Torque Requirements; Table 2
  • Page 25 – Specifications; Electrical Performance
Loading the manual

About These Installation Instructions - - - - - - - - - - - - - - - - - - - - - - 2
Important Safety Instructions - - - - - - - - - - - - - - - - - - - - - - - - - - - 3
Installation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6

Main Components - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6

AC/DC Distribution Panel - - - - - - - - - - - - - - - - - - - - - - - 7

Installation Codes - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10

Installation Tools and Materials- - - - - - - - - - - - - - - - - - - - - - - 10

Choosing a Location - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11

Installing the XADC (stand-alone unit)- - - - - - - - - - - - - - - - - - 12

Preparing to Install - - - - - - - - - - - - - - - - - - - - - - - - - - - - 12
Preparing the Mounting Location for the XADC - - - - - - - - 13
Connecting the DC Battery - - - - - - - - - - - - - - - - - - - - - - - 13
Connecting the AC Input - - - - - - - - - - - - - - - - - - - - - - - - 14
Mounting the XADC - - - - - - - - - - - - - - - - - - - - - - - - - - - 15

Installing XADC with the AC/DC Distribution Panel - - - - - - - - 15

Configurations - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 15
Preparing to Install - - - - - - - - - - - - - - - - - - - - - - - - - - - - 15
Connecting the XADC and Panel Together - - - - - - - - - - - - 17
Preparing the Mounting Location for the XADC and Panel - 18
Connection Types for AC and DC - - - - - - - - - - - - - - - - - - 18
Connecting the DC to the Panel - - - - - - - - - - - - - - - - - - - - 18
Connecting the Panel to the XADC DC Side - - - - - - - - - - - 20
Connecting the Panel to the XADC AC Side - - - - - - - - - - - 21
Connecting the AC to the Panel - - - - - - - - - - - - - - - - - - - - 22
Mounting the XADC and Panel when Connected - - - - - - - - 23
Mounting the XADC and Panel Remotely - - - - - - - - - - - - - 24

DC Wire Size and Torque Values - - - - - - - - - - - - - - - - - - - - - 24

Specifications - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 25

Electrical Performance - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 25

Mechanical Specifications - - - - - - - - - - - - - - - - - - - - - - - - - - 25

Xantrex AC to DC Converter
Installation Instructions

XADC

975-0301-01-01 Revision E

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - About These Installation Instructions; Purpose; The purpose of these Installation Instructions is to provide; Audience; The following conventions are used in this guide.; WARNING

Xantrex AC to DC Converter 2 975-0301-01-01 About These Installation Instructions Purpose The purpose of these Installation Instructions is to provide explanations and procedures for installing the Xantrex AC to DC Converter (XADC). The Installation Instructions provide safety guidelines and procedu...

Page 3 - Important Safety Instructions; WARNING: Limitations on Use

Installation Instructions 975-0301-01-01 3 Important Safety Instructions 1. Before installing and using the XADC, read all instructions and cautionary markings on the XADC, the batteries, and all appropriate sections of this guide. 2. Do not expose the XADC to rain, snow, spray, or water. To reduce ...

Page 4 - Explosive Gas Precautions; Make sure the area around the battery is well ventilated.; WARNING: Explosion hazard

Xantrex AC to DC Converter 4 975-0301-01-01 Explosive Gas Precautions Precautions When Working With Batteries 3. Make sure the area around the battery is well ventilated. 4. Never smoke or allow a spark or flame near the engine or batteries. 5. Use caution to reduce the risk or dropping a metal tool...