Set-Up and Operating Instructions for MS12A Occupancy Sensor/Motion Detector

The MS12A Motion Detector sends Wireless Radio Frequency (RF) signals to an X-10 Transceiver (RR501 or
TM751) or any X-10 security system base receiver. The receiver then passes the signals onto your house wiring to
turn on lights (or appliances) around your home. You plug your lights and appliances into X-10 Modules (sold
separately). The MS12A also works with the CM11A Two-Way Computer Interf ace to initiate macros (routines) so
you can set up a “coming home” routine which is initiated by the Motion Detector as soon as it “sees” you.

Remove the battery cover on the front of the MS12A and install tw o AAA alkaline batteries. The unit defaults to
Housecode A and Unit Code 1, so if that's what code you want it to control, you are finished setting up the
MS12A. Refit the battery cover.

Plug in an X-10 RF Transceiver (model RR501 or TM751, sold separately) or any X-10 security system base
receiver (sold separately) and set it to Housecode A. Plug a lamp into an X-10 Lamp Module (sold separately)
and set it to Housecode A and Unit Code 1. Plug the module into any AC outlet.

Place the MS12A on a shelf or mount it on a wall at least 6 feet above the ground. Let it settle for a min ute and
then walk past it. The lamp connected to any X-10 Module set to A1 will turn on. The light will turn off apr ox. 6
min utes later as long as no motion has been detected. You can also turn the light off from any X-10 controller or
set up a CM11A Computer Interface (sold separ ately) to initiate a macro when it receives A1. This macro could
for example tur n on a group of lights (e.g. B2, C7, and H9) when you walk into a room and turn them off after a
preset time. Note that the MS12A has a built-in photocell that detects when it's dark. It therefor e only turns lights
on when it's dark. It does not transmit during daylight. Care should be taken theref ore to place the MS12A w here
it sees plenty of sunlight during the day (such as near a window). If you place it in a dark corner, it might always
turn lights on (even during the day). Care should also be taken not to place the MS12A near the light it is control-
ling, otherwise when the light turns on it might "fool" the MS12A into thinking it's daytime!

X-10 (USA) Inc. 91 Ruckman Rd., Closter, NJ 07624

(201) 784-9700. Fax (201) 784-9464. http://www.x10.com

DR/MS12A-10/97

To change the Unit Code for the MS12A: Press and hold the Unit button (under the battery compar tment
lid) until the red light blinks twice, then release and press the button the desir ed number of times for the Unit
Code y ou want (once for Unit Code 1, twice for Unit Code 2, etc.). The light blinks each time you press, and
confir ms your entry by blinking the number of times you pr essed the button about 2 seconds after your last
press. Use the same procedure to change the Housecode (pr essing the House button instead). One press for
Housecode A, two presses for B, etc. To check what code you've set: press and release the House or Unit
code button - the light blinks back the appropriate number of times for the code that is set.

To test the MS12A: Set the RR501, TM751, or security console to the same Housecode as the MS12A. Walk
past the MS12A. OR: Press its Housecode button to turn the desired light ON . Press its Unit Code button to turn
the desired light OFF. (Note: the lights blinks to appropr iate number of times for the code that is set).

To turn lights on when it gets dark. The MS12A sends signals w hen it detects dusk and dawn so it can turn a
light on when it gets dark and turn it off when it gets light (in addition to turning lights on when it detects
motion, w hen it's dark). To have it turn a light on at dusk and off at dawn plug the light into an X-10 Module and
set it to the same Housecode as the MS12A and to a Unit Code that is one number higher that the Unit Code of
the module that turns on when motion is detected. I.E. if the MS12A turns on A1 when it detects motion, it will
turn on A2 when it gets dark and turn it off when it gets light.

F.C.C. CAUTION - THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS
SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL
INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED,
INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.

NOTE: NO CHANGES OR MODIFICATIONS MAY BE MADE TO THE UNITS. ANY CHANGES
MADE TO THE UNITS WILL VOID THE USER'S AUTHORITY TO OPERATE THE EQUIPMENT.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other X10 Models

All X10 Other