Williams 1773511 - Manual

Williams 1773511

Williams 1773511 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
Page: / 24

Table of Contents:

  • Page 2 – Installation and repair should be done by a; QUALIFIED SERVICE TECHNICIAN.
  • Page 3 – That’s your signal to go into immediate action!
  • Page 4 – Some Points to Remember; Learn to recognize the odor of LP Gas.; Technical Data
  • Page 6 – Outside Location for Vent Terminal
  • Page 7 – use the plastic anchors provided.; RUBBER SILCONE O-RING GASKET IS IN POSITION.
  • Page 8 – gas leaks before operating the furnace.
  • Page 9 – Gas Conversions
  • Page 10 – Attention; High Altitude Adjustment; Altitude
  • Page 11 – Checking the Gas Inlet Pressure
  • Page 12 – Electrical Wiring Diagram
  • Page 13 – Operating Instructions; WHAT TO DO IF YOU SMELL GAS:; FOR YOUR SAFETY READ BEFORE OPERATING; OPERATING INSTRUCTIONS
  • Page 14 – WHAT TO DO IF THE RED LAMP IS LIT; ONE; of; HOW TO SHUT OFF THE APPLIANCE; OR; USING THE FEATURES OF YOUR FURNACE; GREEN LAMP; W hen the button is down, the furnace keeps the
  • Page 15 – Do not push; ubrication of Moving Parts; them inside the furnace.
  • Page 16 – Annual Maintenance Requirements; Check for gas leaks on all connections.
  • Page 18 – Setting and Adjustment; E EE; Initial Conditions; and is independent of the timer program.; Day and Time Setting; number 2 without the light symbol. The OFF time may now be set.
  • Page 19 – The preset program will restart and SKIP symbol (; Skip Function Procedure During Operation; A. The SKIP function can be activated only in RUN mode.
  • Page 20 – Troubleshooting; Step 1
  • Page 21 – thermostat with a clockwise rotation.; Troubleshooting Step 4
  • Page 23 – Replacement Parts; Electric Box
Loading the manual

















Installation Instructions and Owner’s Manual

Direct-Vent Wall Furnace










- Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Open all windows.
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Extinguish any open flame.
• Immediately call your gas supplier
from a neighbor’s phone. Follow
the gas supplier’s instructions.
• If you cannot reach your gas supplier,
call the fire department.
- Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.

WARNING

: If the information in this

manual is not followed exactly; a fire
or explosion may result, causing
property damage, personal injury or
loss of life.

Williams Furnace Co., 250 West Laurel Street, Colton, CA 92324 U.S.A.






MODEL:

Natural Gas

1773512








MODEL:

Propane Gas

1773511

WARNING: Improper installation, adjustment,

alteration, service, or maintenance can cause

injury or property damage. Refer to this

manual. For assistance or additional

information, consult a qualified installer,

service agency or the gas supplier

.

WARNING: Installation and repair must be

done by a qualified service person. The

furnace should be inspected before use and at

least annually by a professional service

person.

WARNING: If not installed, operated and

maintained in accordance with the

manufacturer’s instructions, this

product could expose you to substances in

fuel or from fuel combustion which can cause

death or serious illness and which are known

to cause cancer, birth defects or other

reproductive harm.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Installation and repair should be done by a; QUALIFIED SERVICE TECHNICIAN.

Table of Contents General Information and Technical Data This furnace is design certified to ANSI Z21.86-2004 / CSA 2.32-2004 Gas–Fired Gravity and Fan-Type, Direct-Vent Wall Furnaces as a Fan-Type Direct-Vent Wall Furnace to be installed on an outside wall according to these instructions. Any alter...

Page 3 - That’s your signal to go into immediate action!

2 Safety Rules and General Warnings DO NOT OPERATE THIS FURNACE WITHOUT FRONT PANEL INSTALLED • Due to high temperatures, the furnace should be located out of traffic and away from any combustible materials such as furniture and draperies. • Children and adults should be alerted to the hazards of hi...

Page 4 - Some Points to Remember; Learn to recognize the odor of LP Gas.; Technical Data

Some Points to Remember • Learn to recognize the odor of LP Gas. Your local LP Gas dealer can give you a ”Scratch and Sniff” pamphlet. Use it to find out what the propane odor smells like. If you suspect that your LP Gas has a weak or abnormal odor, call your LP Gas dealer. • If you are not qualifie...

Other Williams Models