Page 2 - Safety Precautions; Table of Contents; Troubleshooting Tips
Safety Precautions . ........................................................................................................................................................... Safety Precautions Installation Instructions Operating Instructions Maintenance Table of Contents Control Panel Features .....
Page 3 - Page 3; Read Safety Precautions Before Operation and Installation; Page 3; WARNING; This symbol indicates the possibility of; space to the combustible
Safety Page 3 Safety Precautions Read Safety Precautions Before Operation and Installation To prevent death or injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause death, harm or damage....
Page 4 - plugged into
Safety Precautions Page 4 •• • • • In a thunderstorm, the power must be cut off to avoid damage to the machine due to lightning. Your air conditioner should be used in such a way that it is protected from moisture. e.g. condensation, splashed water, etc. Do not place or store your air conditione...
Page 5 - Please follow the instruction; SAFETY COMPLIANCE
Safety Precautions Page 5 • • • •• Do not use hazardous chemicals to clean or come into contact with the unit. Do not use the unit in the presence of inflammable substances or vapour such as alcohol, insecticides, petrol,etc. Always transport your air conditioner in a vertical position and stand...
Page 6 - Page; the
Safety Precautions Page 6 1. Transport of equipment containing flammable refrigerants . See transport regulations 2. Marking of equipment using signs . See local regulations 3. Disposal of equipment using flammable refrigerants . See national regulations. 4. Storage of equipment/appliances . The...
Page 7 - )Presence of fire extinguisher
Precautions Safety Page 7 5)Presence of fire extinguisher If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriatefire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisheradjacent to the charging area. 6)No i...
Page 10 - Installation Instructions; Preparation
Page 10 Installation Instructions Installation Instructions Preparation NOTE:All the illustrations in the manual are for explanation purpose only. Your machine may be slightly different. The actual shape shall prevail. The unit can be controlled by the unit control panel alone or with the remote...
Page 11 - Choosing The Right Location; could cause damage to the unit.; Energy Rating Information; Recommended; Ambient Temperature Range For Unit Operating; Exhaust Hose Installation
Page 11 50cm 50cm 20 inch 50cm 20 inch 20 i nch Installation Instructions Choosing The Right Location Recommend Installation Your installation location should meet the following requirements:-Make sure that you install your unit on an even surface to minimize noise and vibration. -The unit must ...
Page 13 - Accessories; ACCESSORY IMAGE; Tools Needed
Page 1 3 Installation Instructions 增加了加长软管的安装与说明 Accessories ACCESSORY IMAGE ACCESSORY DESCRIPTION QUANTITY Exhaust hose adapter to the unit 1 piece Exhaust hose 1 piece Exhaust hose adapter to the window 1 piece Window slider kit 1 set Clear plastic plug (plug is in the upper corner of the plas...
Page 14 - Control Panel
Page 14 Installation Instructions Power Button Press to turn the air conditioner on and off Mode Button Press to change mode • Controls the 3 function modes: COOL, FAN, and DRY. Note: In Cooling or Dry mode, press the Mode for 3 seconds to turn the Constant Fan function on or off. When the funct...
Page 18 - Operation Instructions
Operation Instructions Page 18 Operating Instructions BEFORE USING YOUR APPLIANCE Remove the exterior and interior packing Before connecting the appliance to the power source, let it stand upright for approximately 4 hours. This will reduce the possibility of amalfunction in the cooling syst...
Page 20 - Remote Control
Remote Control Other appliances in the same room controlled by a remote control (TV, radio, stereo, etc.), may cause interferences Electronic and fluorescent lamps may interfere with the signal transmissions between the remote control and the air conditioner Remove the batteries if the remote ...
Page 22 - Problem
Troubleshooting Tips Troubleshooting Tips Page 22 Problem Possible Causes Solutions The portable air conditioner does not turn on Power failure / outage The automatic switch, line fuse, or breaker has been tripped The power supply voltage is too low The power cord is damaged The L.C.D....
Page 24 - form. Please be sure to include a copy of your purchase invoice.
ONE YEAR LIMITED WARRANTY & THREE YEAR WARRANTY ON COMPRESSOR This WHYNTER product is warranted to the original owner, purchased from an authorized Whynter dealer within the 48 U.S. continental states, for one year from the original purchase date against defects in material and work- manship und...