A user manual for wall-mounted canopy range hoods outlines essential specifications for safe and efficient installation, covering electrical requirements, cabinet dimensions, venting methods (vented or recirculating), and critical measurements like clearance and chimney height. The guide emphasizes proper ductwork design–including equivalent length calculations for elbows, caps, and straight sections–to ensure optimal airflow and compliance with safety standards. It also addresses practical configurations such as roof or wall venting and rear discharge systems.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
Page: / 4

Table of Contents:

  • Page 1 – Installation Specifications for Wall-Mount Canopy Range Hoods
  • Page 2 – Venting Methods and Equivalent Length Calculation
  • Page 3 – Installation Requirements for Wall-Mounted Range Hoods
  • Page 4 – Exhaust System Installation and Circuit Calculation
Loading the manual
Page 1

Page 1 of 4

PRODUCT MODEL NUMBERS

WVW73UC0LS WVW73UC6LS WVW53UC0LS WVW53UC6LS

30" (76.2 cm) and 36" (91.4 cm) Wall-Mount Canopy Range Hood

PRODUCT DIMENSIONS

* For non-vented (recirculating) installations

** For vented installations.

VENTING REQUIREMENTS

Vent system must terminate to the outdoors except for non-vented
(recirculating) installations.

Do not terminate the vent system in an attic or other enclosed area.

Do not use 4" (10.2 cm) laundry-type wall cap.

Use metal vent only. Rigid metal vent is recommended. Plastic or
metal foil vent is not recommended.

The length of vent system and number of elbows should be kept to a
minimum to provide efficient performance.

For the Most Efficient and Quiet Operation:

Use no more than three 90° elbows.

Make sure there is a minimum of 24" (61 cm) of straight vent between
the elbows if more than 1 elbow is used.

Do not install 2 elbows together.

Use clamps to seal all joints in the vent system.

The vent system must have a damper. If the roof or wall cap has a
damper, do not use the damper supplied with the range hood.

Use caulking to seal exterior wall or roof opening around the cap.

The size of the vent should be uniform.

IMPORTANT:

Minimum distance “X”: 24" (61 cm) from electric cooking surface

Minimum distance “X”: 27" (68.6 cm) from gas cooking surface

Suggested maximum distance “X”: 36" (91.4 cm)

The chimneys can be adjusted for different ceiling heights. See the
following chart.

Vented Installations

Min. ceiling height

Max. ceiling height

Electric cooking surface

7' 5" (2.26 m)

9' 2" (2.79 m)

Gas cooking surface

7' 8" (2.34 m)

9' 2" (2.79 m)

Non-Vented (Recirculating) Installations

Min. ceiling height

Max. ceiling height

Electric cooking surface

7' 5" (2.26 m)

9' 6" (2.9 m)

Gas cooking surface

7' 8" (2.34 m)

9' 6" (2.9 m)

NOTE:

The range hood chimneys are adjustable and designed to

meet varying ceiling or soffit heights depending on the distance “X”
between the bottom of the range hood and the cooking surface. For
higher ceilings, a Stainless Steel Chimney Extension Kit is available
from your dealer or an authorized parts

distributor. The chimney

extension replaces the upper chimney shipped

with the range hood.

ELECTRICAL REQUIREMENTS

A 120 volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required

CABINET DIMENSIONS

Because Whirlpool Corporation includes a continues commitment to improve our
products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.

Side

cabinet

Side

cabinet

Centerline

Cooking surface

30" (76 cm) or
36" (91.2 cm)

16

14

13

/ " (37.7 cm)

8

13

3

/ "

(34 cm)

“X”

bottom of

canopy

to cooking

surface

15" (38.1 cm)

83/

16

"

(20.8 cm)

71/

4

"

(18.3 cm)

*28

7

/

8

"(73.3 cm) min.

421/

16

"(107.5 cm) max.

**28

5

/

8

"(72.7 cm) min.

38"(97.7 cm) max.

14"

(35.6 cm)

17

7

/

8

"

(45.4 cm)

2

11/ " (3.9 cm)

101/

4

"

(26 cm)

30" (76 cm)

36" (91.2 cm)

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Was this manual helpful?

About this manual

Brand
Whirlpool
Model
WVW73UC0LS
Document type
Manual
Category
Range Hood
Language(s)
English, French
Pages
4
File size
230.6 KB
Format
PDF

Summary

Page 1 - Installation Specifications for Wall-Mount Canopy Range Hoods

Specifications covering 30" and 36" wall-mount canopy range hoods, including model numbers, electrical requirements, cabinet dimensions, venting needs, and guidelines for vented and recirculating installations.

Page 2 - Venting Methods and Equivalent Length Calculation

Methods for venting a canopy hood, including roof or wall venting and rear discharge options. Calculation of equivalent vent system length using measurements for elbows, caps, and straight sections.

Page 3 - Installation Requirements for Wall-Mounted Range Hoods

Requirements for installing 30" and 36" wall-mounted range hoods, detailing electrical needs, precise installation dimensions, duct size, material selection, and clearance from combustible surfaces.

Ask a question

Up to 3 photos. Max 5 MB each. Formats: JPG, JPEG, PNG, WebP.