  • Page 2 – GOLD GV Series 3 & 4 — Z-Vent II Venting Supplement; Combustion air supply; Table 1; Corrosive contaminants; Special note; Products to avoid
  • Page 3 – Vent termination; Venting method definitions; Properly locate vent termination; Figure 1; Vent termination locations
  • Page 4 – Installation; Pre-installation planning; Choose vent method from those shown on page 5.; Table 3; Vent and combustion air connector piping; Out; Figure 2; Boiler output; Table 2; Parts list
  • Page 5 – Figure 3; GV direct vent through sidewall; continued; Figure 4; GV non-direct vent through sidewall; Figure 5; GV direct vent; Figure 6; through sidewall; Figure 7; through roof; Select vent method
  • Page 6 – Installation — assembly; Connect vent starter tee to boiler; Do not mix types or manufacturers of vent materials.; Connect vent run to termination; Venting through sidewall; Refer to vent termination WARNING, item 19 on page 3.; Venting through existing chimney or roof
  • Page 7 – Figure 8; Non-direct vent through sidewall
  • Page 8 – Finish the vent installation; Installing condensate tubing; use a low-profile pump — OR —; provided by; Vent; If vent pipe or combustion air pipe must be reassembled
Loading the manual

Part number 550-110-266/0601

Hazard definitions

The following defined terms are used throughout these Instructions to bring attention to the
presence of hazards of various risk levels or to important information concerning the life of
the product.

Indicates presence of hazards that

will cause severe

personal injury, death

or substantial property damage.
Indicates presence of hazards that

can cause severe

personal injury, death

or substantial property damage.
Indicates presence of hazards that

will or can cause minor

personal injury

or property damage.
Indicates special instructions on installation, operation or maintenance that
are important but not related to personal injury or property damage.

To the installer:

This Venting Supplement must only be used by a qualified installer/service
technician. Read these Instructions completely before beginning the
installation. Failure to follow all instructions can cause severe personal injury,
death or substantial property damage.

To install a new vent system follow instructions in:

This Venting Supplement.

GV Boilers Vent/Air Intake Termination Assembly Instructions, if
using Weil-McLain Vent/Air Intake Termination Kit. — OR —

GV Water Boiler Series 3 & 4 Direct Vent Through-Roof or Through-
Unused-Chimney Vent ing Su pplement, if using Weil-McLain
Through-Roof or Through-Unused-Chimney Termination Kit.

Z-Vent II manufacturer’s instructions supplied with vent material.

For installations above 5,500 feet use only direct vent (ducted combustion
air) when sidewall venting. All of the vertical (through-roof or through-
unused-chimney) methods in this Venting Supplement are acceptable and
can result in severe personal injury, death or substantial property damage
if ignored.

Z-Vent II

Venting Supplement

Special gas vent system vent and combustion air supplement

Z-Flex

®

, Inc. Z-Vent II AL29-4C

®

Stainless Steel Special Gas Vent System may be used in new

installations of GV-3 through GV-6 boilers.

GOLD

Water Boiler — Series 3 & 4

GV

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - GOLD GV Series 3 & 4 — Z-Vent II Venting Supplement; Combustion air supply; Table 1; Corrosive contaminants; Special note; Products to avoid

Part number 550-110-266/0601 2 GOLD GV Series 3 & 4 — Z-Vent II Venting Supplement Combustion air supply Table 1 Corrosive contaminants Special note Refer to GV Boiler Manual for sizing free area of combustion/ventilation air openings.All boilers experience some condensation in section assembly ...

Page 3 - Vent termination; Venting method definitions; Properly locate vent termination; Figure 1; Vent termination locations

Part number 550-110-266/0601 3 GOLD GV Series 3 & 4 — Z-Vent II Venting Supplement Vent termination Venting method definitions Direct vent — Uses outside combust ion air w ith combustion air connector piping sealed at all joints andseams. Also known as “sealed combustion”. Non-Direct vent — Uses...

Page 4 - Installation; Pre-installation planning; Choose vent method from those shown on page 5.; Table 3; Vent and combustion air connector piping; Out; Figure 2; Boiler output; Table 2; Parts list

Part number 550-110-266/0601 4 GOLD GV Series 3 & 4 — Z-Vent II Venting Supplement Installation Pre-installation planning 1. Follow national, state, local or provincial codes orregulations when venting GV boiler. 2. Choose vent method from those shown on page 5. 3. Select vent run components fro...