Weil-McLain Gas Burner - Manual

Weil-McLain Gas Burner

Weil-McLain Gas Burner – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
Page: / 4

Table of Contents:

  • Page 2 – Weil-McLain 88 Water and Steam Boilers — Series 2 —; Table 1; Burner specifications and settings; Notes for Table 1 and Table 2
  • Page 3 – Table 2
  • Page 4 – Notes for Table 3; Table 3
Loading the manual

Part No. 550-142-029/0508

Burner Specification

& Data Sheet

Water & Steam Boilers – Series 2

88

Burner

Model Number

A

B(R)

C(R)

D

E

F*

G

H

I

S

X

Approximate

Weight

WCR1

34.13

5.56

14.50

4.63

12.25

20.00

3.25

7.25

7.38

12.63

7.25

175-200

WCR2

39.13

6.13

14.00

5.25

14.00

20.00

4.00

8.75

8.50

13.38

8.50

220-300

WCR3

44.00

7.00

15.25

6.00

16.00

22.38

5.00

10.13

11.50

15.50

10.00

360-400

WCR4

50.00

7.31

17.69

7.00

18.50

28.00

6.00

12.13

14.25

19.13

12.00

500-550

* Required for installation of standard control components

Model WCR

Figure 1

4.00

A

S

I

H

G

F

X

5/8 Dia., 4 holes

X

E

3.13

Note: Add .38 to “H” dim for size of opening in boiler front plate.

D

C(R)

B(R)

CL

CL

CL

Power Flame

Gas/Oil Burners

Model WCR

For Gas, Light Oil, & Gas/Light Oil – Fired Burners

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Weil-McLain 88 Water and Steam Boilers — Series 2 —; Table 1; Burner specifications and settings; Notes for Table 1 and Table 2

Weil-McLain 88 Water and Steam Boilers — Series 2 — For Gas, Light Oil, & Gas/Light Oil-Fired Burners 2 Part No. 550-142-029/0508 Burner data Table 1 Boiler Model Number Burner Input Positive Pressure In Firebox In. W.C. Standard Burner Model Designation Standard Combustion Control Standard Cont...

Page 3 - Table 2

Burner Specification & Data sheet — Power Flame Gas/Oil Burners — Model WCR 3 Part No. 550-142-029/0508 Burner specifications and settings (continued) Gas train components and flame safeguards Table 2 Boiler Model Number Pressure Drop Thru Gas Train Inches W.C. Manifold Pressure Inches W.C.* Gas...

Page 4 - Notes for Table 3; Table 3

Weil-McLain 88 Water and Steam Boilers — Series 2 — For Gas, Light Oil, & Gas/Light Oil-Fired Burners 4 Part No. 550-142-029/0508 Notes for Table 3 Combustion Controls: 1. R7184P Uses cadmium cell for flame detector to monitor oil burner flame, also furnishes intermittent ignition. RM7897A, RM78...

Other Weil-McLain Models