Weil-McLain BMC-6X - Manual

Weil-McLain BMC-6X

Weil-McLain BMC-6X – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
Page: / 32

Table of Contents:

  • Page 2 – BMC and BMC-6X Installation and Operation Manual; Make Sure You Have the Right Control . . 6; Contents
  • Page 3 – BMC; BMC LAYOUT
  • Page 4 – BMC OVERVIEW
  • Page 5 – UNDERSTANDING OPERATION CONCEPT; RESET RATIO/OUTDOOR RESET; F Outdoor; Type of Radiation in Building; Reset Ratio Curves; WARNING
  • Page 6 – INITIAL SETUP; SELECTING THE SYSTEM FEATURES
  • Page 7 – INSTALLATION; The Enclosure Display Module:; MOUNTING THE ENCLOSURE; Select a location near the equipment to be controlled.
  • Page 8 – LOCATING HSS; Do not run sensor wires in conduit with line voltage wiring.; IMMERSION HEATING SYSTEM SENSOR (HSS) INSTALLATION; Insert the sensor probe of the supplied sensor into the well.; ALERT; OUTDOOR SENSOR INSTALLATION; Adhere the Outdoor Label provided to the back of the sensor base.; Outdoor Sensor
  • Page 9 – Connect the hot line to terminal marked L.; WIRING THE SENSORS; Connect the shield to the circled terminal; Bring the two wires from the dry contact to the terminals marked
  • Page 10 – PROVE; DHW Call; System Output Operation in Set Point Mode; System Output Operation in Reset Mode; WIRING THE BOILERS
  • Page 11 – WIRING TO MODULATING MOTORS; The BMC can operate up to four 4-20 mA modulating motors.; CONNECTING TO THE BMC-6X PANELS; Only 6-wire phone cable must be used for proper operation.; Connecting BMC to
  • Page 12 – STARTUP; HISTORIES; MENU SEQUENCE
  • Page 13 – SYSTEM SETTINGS1; MAINTENANCE
  • Page 14 – PROGRAM CHANGE SETTINGS; STARTUP SEQUENCE; SENSOR TYPE; Set Point °F, Set Point; EMS INPUT MODE (AVAILABLE IN SET POINT ONLY); mA Adjustable from 70; The 4mA can be set to any temperature between 70oF to 200oF.; SELECTING THE OUTPUT TYPE
  • Page 15 – SELECTING THE MODULATING MODE; Prove, DHW Without Priority, DHW With Priority
  • Page 16 – SENSOR FAULT; RESET MODE; SETTING THE CONTROL TO FACTORY DEFAULTS; screen appears. The Display will direct you to the Startup menu to
  • Page 17 – SEASON; Summer; Adjustable from 70; RESET RATIO; If; Adjust the RESET RATIO in cold weather.; If the ambient building
  • Page 18 – OUTDOOR CUTOFF TEMPERATURE; MINIMUM WATER TEMP
  • Page 19 – GAIN; MUST; Purge Delay
  • Page 20 – LAG DELAY; Adjustable from 0min to 60min; Lag Delay; STANDBY DELAY; Adjustable from 1min to 60min; A boiler can be set to be a Standby boiler using the Stage Menu.; Adjustable from 0min to 360min; SETBACK; Adjustable from 0F
  • Page 21 – LAST STAGE HOLD; AVOIDING CONFLICTING BOILER LIMITS
  • Page 22 – SET TIME; HISTORY
  • Page 23 – SYSTEM & OUTDOOR SENSOR TRIM; Adjustable from 0sec to; OUTPUT TRIM
  • Page 24 – CONFIGURATION; DISPLAY; DISPLAY BOILER MODULATION STATUS
  • Page 25 – DISPLAY MESSAGES; BOILER STAGE SETTINGS; STAGE; MODE
  • Page 26 – Auto; disable units that are being serviced.; On; boiler will immediately start firing and modulate to 100%.; COPY SETTINGS - BOILER A ONLY
  • Page 27 – TROUBLESHOOTING
  • Page 28 – Boilers are Short-Cycling; - Increase the Lag Delay only if all boilers tend to short-cycle.; System is Overshooting or Undershooting; - If the system is overshooting reduce the Gain.
  • Page 29 – MULTIPLE MODULATING BOILERS; DIRECT HEATING PIPING DIAGRAM
  • Page 30 – DIRECT HEATING WIRING DIAGRAM; Outputs
  • Page 31 – EXTERNAL 4-20MA SET POINT
  • Page 32 – SPECIFICATIONS; BMC SPECIFICATIONS; Heating system sensor -35; BMC-6X SPECIFICATIONS; Modulating Output Types:
Loading the manual

1

BMC and BMC-6X Installation and Operation Manual

BMC

SYSTEM

A

B

C

D

Full Modulation Sequencing Control

1

2

RUN

PROGRAM

FOR ALL CIRCUITS

120VAC, 6A RESISTIVE

OUTPUT RATINGS:

1A PILOT DUTY, 15A TOTAL

115VAC 60Hz , 30VA MAX

INPUT RATINGS:

USE COPPER WIRE,

DO NOT APPLY ANY VOLTAGE

TO INPUT TERMINALS

3

4

5

6

7

8

9 10 11 12

13

15

14

17

16

18

22

20

19

21

24

23

29

25

27

26

28

32

30 31

L N

-

+

+

T

T

O

O

RS-485

mA

GND

VLT

SYS

A

B

C

D

PWR

CUR / VLT

A

-

+

+

mA

GND

VLT

-

+

+

mA

GND

VLT

-

+

+

mA

GND

VLT

+

mA

TEMP

OUTDOOR

O

O

TEMP

SYSTEM

EXTENSION

MODULE

CUR / VLT

B

CUR / VLT

C

CUR / VLT

D

CLASS 1 WIRE ONLY.

---

---

SYSTEM
PROVE

SHUTDOWN

/TSTAT

/SETBACK

ENCLOSED

ENERGY

MANAGEMENT

EQUIPMENT

LISTED

99RA

CAUTION

: RISK OF ELECTRIC SHOCK

More than one disconnect switch may be required
to de-energize the equipment before servicing.

C

US

• INSTALLATION AND OPERATION INSTRUCTIONS MANUAL

BMC

AND

BMC-6X

HYDRONIC MODULATING BOILER CONTROL AND EXTENSION

This Weil McLain control is strictly an operating control; it should never be used as a
primary limit or safety control. All equipment must have its own certified limit and safety
controls required by local codes. The installer must verify proper operation and correct any
safety problems prior to the installation of this Weil McLain control.

WARNING

Part Number 550-100-072/0408

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - BMC and BMC-6X Installation and Operation Manual; Make Sure You Have the Right Control . . 6; Contents

2 BMC and BMC-6X Installation and Operation Manual BMC LAYOUT . . . . . . . . . . . . . . . . 3 BMC OVERVIEW . . . . . . . . . . . . . . 4 Reset Ratio/Outdoor Reset . . . . . . . . . . 5 Make Sure You Have the Right Control . . 6 INITIAL SETUP . . . . . . . . . . . . . . . 6 Selecting the System Fea...

Page 3 - BMC; BMC LAYOUT

3 BMC and BMC-6X Installation and Operation Manual BMC SYSTEM A B C D Full Modulation Sequencing Control 1 2 RUN PROGRAM FOR ALL CIRCUITS 120VAC, 6A RESISTIVE OUTPUT RATINGS: 1A PILOT DUTY, 15A TOTAL 115VAC 60Hz , 30VA MAX INPUT RATINGS: USE COPPER WIRE, DO NOT APPLY ANY VOLTAGE TO INPUT TERMINALS 3...

Page 4 - BMC OVERVIEW

4 BMC and BMC-6X Installation and Operation Manual BMC OVERVIEW SEQUENCES UP TO 4 FULLY MODULATING STAGES. The BMC is the perfect control whenever multiple fully modulating stages are required for hydronic heating applications. The BMC controls the on/off and the modulation of each stage to maintain...