Wayne GPB400 - Manual

Wayne GPB400

Wayne GPB400 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
Page: / 20

Table of Contents:

  • Page 2 – PIPING; Maintenance; Installation
  • Page 3 – Performance Information; ” Cast Iron Pump Performance; CAPACITIES IN GALLONS PER HOUR; PERFORMANCE CURVE
  • Page 5 – Notes
  • Page 6 – Maintenance / Service Record; Date; Operating Instructions and Replacement Parts List
  • Page 8 – Limited Warranty; MUST; send a; COPY; return authorization and instructions.; DO NOT MAIL THIS FORM TO WAYNE PUMPS.; Use this form only to maintain your records.; ATTACH YOUR RECEIPT HERE
  • Page 9 – PROPOSITION 65 DE LA CALIFORNIE; Mode d’emploi et Liste de Pièces de Rechange
  • Page 10 – TUYAUTERIE; Entretien
  • Page 11 – Informations sur le Rendement; Performance de la pompe en fonte 5 cm (2 po); CAPACITÉS EN GALLONS PAR HEURE; Taille du; Gallons à la minute; COURBE DE RENDEMENT
  • Page 13 – Remarques
  • Page 14 – Garantie limitée; présenter une réclamation de garantie, il; FAUT; envoyer une; COPIE; pour l’autorisation et instructions concernant le renvoi.; NE PAS POSTER CE FORMULAIRE À WAYNE PUMPS.; Utiliser ce formulaire seulement pour vos archives.; ATTACHER LE REÇU ICI
  • Page 15 – PROPOSICIÓN DE CALIFORNIA 65; Instalación; Instrucciones de funcionamiento y Lista de piezas de repuesto
  • Page 16 – TUBERÍAS; Mantenimiento
  • Page 17 – Información del rendimiento; CAPACIDADES EN GALONES POR HORA; CURVA DE RENDIMIENTO
  • Page 19 – Notas
  • Page 20 – Garantía limitada; conservar su recibo de; DEBE; enviar una; COPIA; del recibo; NO ENVÍE ESTE FORMULARIO A WAYNE PUMPS.; Use este formulario sólo para mantener sus registros.; SUJETE SU RECIBO AQUÍ
Loading the manual

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect
yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage!
Retain instructions for future reference.

Engine Driven
Centrifugal Pump

Description

The WAYNE pumps are general use
centrifugal water pumps. The pump
is equipped with EPDM seals that are
intended for water use only.

Safety Guidelines

This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.

Danger indicates an

imminently

hazardous

situation which, if NOT avoided, WILL
result in death or serious injury.

Warning indicates a

potentially

hazardous

situation which, if NOT avoided, COULD
result in death or serious injury.

Caution indicates a

potentially minor or

moderate injury, if NOT avoided, MAY
result in serious injury.
Notice

indicates

important

information, that if NOT followed, MAY
cause damage to equipment.

General Safety
Information

CALIFORNIA PROPOSITION 65

This product may

contain

chemicals

known to the State of California to
cause cancer and birth defects or other
reproductive harm. Wash hands after
handling.

1. Know the pump application,

limitations, and potential hazards.
Read these rules and the instructions
carefully. Failure to follow them could
cause serious bodily injury and/or
property damage.

NEVER

run

engine

in

an enclosed area. Exhaust
gases contain deadly
poisonous carbon monoxide,
which has no odor or taste.

Do NOT use

to pump

flammable or explosive fluids
such as gasoline, fuel oil,
kerosene, etc. Do NOT use in
flammable and/or explosive atmospheres.
Pump SHOULD only be used with liquids
compatible with pump component materials.
Failure to follow this warning CAN result in
personal injury and/or property damage.

2. Observe all safety precautions for the

handling of the fuel.

Do

NOT

refuel

a

hot engine. Fuel spilled on a
hot engine could result in a
fire or explosion. Do NOT
refuel a running engine.

3. Pump should be located and should

rest on a level solid foundation. Do
NOT suspend pump by means of the
discharge pipe.

Be sure pump is on

secure footing so it

doesn’t fall over.

4. Do NOT use torches or apply excessive

heat, fire or flames to this pump as an
explosion may result.

5. Before working on the unit, insulate

the wire from the spark plug, by
disconnecting the spark plug wire from
the spark plug.

Complete

pump and

piping

system

MUST be protected against below freezing
temperature. Failure to do so COULD cause
serious damage and WILL void the warranty.

6.

Do NOT run pump dry. Water is
required to lubricate the shaft seal.

7. Pumping chemicals or corrosive liquids

with this pump will shorten the life of
the pump and may be hazardous to the
operator and void the warranty.

8. Personal

Safety:

a. Wear safety glasses at all times when

working with pumps.

b. Keep work area clean, uncluttered

and properly lighted; replace all
unused tools and equipment.

c. Keep visitors at a safe distance from

the work area.

d. Make workshop child-proof with

padlocks, master switches, and by
removing starter keys.

9. This pump is designed for non-abrasive

fluid transfer; do NOT use as a trash
pump. ALWAYS use a suction strainer
with this pump to filter abrasive
material. Abrasive materials such as sand
and gravel will shorten the life of the
pump.

Installation

This pump is designed to be self-priming
when installed and operated as specified
below.

1. The pump should be placed as close as

possible to the water being pumped.
A pump with 20 foot suction lift will
not remove water as quickly as a pump
with 5 foot suction lift (Figure 1).

Operating Instructions and Replacement Parts List

GPB400

REMINDER: Keep your dated proof of purchase for warranty purposes!

Attach it to this manual or fi le it for safekeeping.

© 2011, WAYNE/Scott Fetzer Company.

320605-001 8/11

For parts, product & service information

visit

www.waynepumps.com

Figure 1

20 FT. SUCTION LIFT

5 Ft.

SUCTION

LIFT

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - PIPING; Maintenance; Installation

2 2. Suction hose and fitting must be airtight. An air leak in the suction line MAY prevent priming of the pump. Use of thread sealant is recommended. Suction lines must be reinforced hose or rigid pipe. Non-reinforced hose will collapse due to the suction created by the pump and prevent pump from o...

Page 3 - Performance Information; ” Cast Iron Pump Performance; CAPACITIES IN GALLONS PER HOUR; PERFORMANCE CURVE

3 Performance Information PERFORMANCE CURVE 100 80 60 40 20 1200 2400 3600 4800 6000 7200 Capacity - GPH To tal Dynamic Head - FEET 0 2” Cast Iron Pump Performance GPB400 www.waynepumps.com CAPACITIES IN GALLONS PER HOUR Discharge Head - Feet Dynamic Suction Lift - Feet 0 5 10 15 20 25 20 6600 6420 ...

Page 5 - Notes

Other Wayne Models

All Wayne Other