Wayne 351203-001 - Manual

Wayne 351203-001

Wayne 351203-001 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 2 – Operation; Green
  • Page 3 – Red; Maintenance; NOTE; Troubleshooting Chart
  • Page 4 – Limited Warranty
  • Page 5 – Instructions D’Utilisation Et Manuel De Pièces; MÉMENTO: Gardez votre preuve datée d'achat à fin de la garantie!
  • Page 6 – Fonctionnement; Vert
  • Page 7 – Une tonalité de trente secondes; Entretien; Vérifier la condition de la batterie; Guide De Dépannage
  • Page 8 – Garantie Limitée
  • Page 9 – El tiempo de recarga de la batería; Instalación; Desconecte la corriente que va a la; Descripción; Use sólo baterías nuevas totalmente; Manual de Instrucciones de Operación y Piezas; Adjúntela a este manual o archívela en lugar seguro.
  • Page 10 – Operación; Verde
  • Page 11 – Mantenimiento; Guía de diagnóstico de averías; Inspeccione los bornes y abrazaderas
  • Page 12 – Garantía Limitada
Loading the manual

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.

1

Description

The ESP15 is a battery operated back-up
sump pump. It does not replace a regular
pump. It is designed to provide protection
in the event household electrical power
fails.

Safety Guidelines

This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.

Danger indicates
an imminently

hazardous situation which, if not avoided,
will result in death or serious injury.

Warning indicates

a potentially

hazardous situation which, if not avoided,
could result in death or serious injury.

Caution indicates a

potentially

hazardous situation which, if not avoided,
may result in minor or moderate injury.

Notice indicates

important

information, that if not followed, may
cause damage to equipment.

General Safety
Information

Do not use to pump
flammable or explosive
fluids such as gasoline, fuel
oil, kerosene, etc. Do not use
in a flammable and/or explosive
atmosphere. Pump should only be used to
pump clear water. Fatal injury and/or
property damage could result.

If the basement has water or
moisture on the floor, do not
walk on wet area until all

Operating Instruction and Parts Manual

ESP15

351203-001 1/06

power is turned off. If the shutoff box is
in the basement, call an electrician.
Remove pump and either repair or
replace. Failure to follow this warning
could result in fatal electrical shock.

All wiring must be
performed by a

qualified electrician.

Do not expose battery to
sparks or flames as an
explosion or fire could
result.

Battery

acid is corrosive. Avoid
spilling on skin or clothing.
Eye protection must be worn
when handling the battery.

A check valve
must be used on

the primary sump pump discharge (see
Figure 1)

A ground fault
circuit interrupter is

required.

This pump must only
be used to pump

clear water. This pump is not designed to
handle effluent, salt water, brine, laundry
discharge or any other application which
may contain caustic chemicals and/or
foreign materials. Pump damage may
occur if used in these applications and
will void warranty.

Battery Requirements

1. Use only a new fully charged 12 volt

deep cycle battery. Electrolyte level
must be checked and maintained in
accordance with manufacturer’s
guidelines.

2. Battery sizes that will fit into the

battery box are 24C, 24VCM, 27C,
27CM and 27F.

3. Battery recharge time will be

different at each installation. Under
normal conditions it will take two to
four days to bring a deep cycle
battery back to full charge after it has

been discharged. If electrical power to
the house is lost more than once a
week, consider keeping a spare, fully-
charged battery to replace an
exhausted battery for the standby
sump pump.

Installation

Installation of this
unit may take

several hours. Before disabling your
main pump, have ready an appropriate
means of evacuating the sump.

1. Turn power to main pump off.

2. Pump must be installed using 1

1

/

4

” or

1

1

/

2

” rigid PVC piping. A check valve

(not included)

must

be installed

between the ESP’s tee and the main
pump (see Figure 1).

3. Measure and cut discharge pipe so

that back-up pump is a minimum of 1
inch above the main pump. This will
allow main pump to operate normally
(see Figure 1).

4. Check the fit of the components

before permanently attaching. Using
PVC cement, glue tee in place. Note

12 Volt
Standby
Sump Pump

© 2006 Wayne Water Systems

Figure 1

1 inch

min.

4 inch min.

Check

valve

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

For parts, product & service information

visit

www.waynewatersystems.com

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Operation; Green

Installation (Continued) the up direction arrow on the tee; thenotch must be to the top or flappervalve will not work (see Figure 2). 5. Insert flapper valve into tee. Be sure locator tab is in the notch in tee (seeFigure 2). 6. Slide clamp onto tee. 7. Insert pump into flapper valve, tilt pump 30˚....

Page 3 - Red; Maintenance; NOTE; Troubleshooting Chart

3 Operation (Continued) Red : Battery is completely discharged or defective. d. Plug in charger and main ACpump. When AC power is out, and whenpump has been running, the lightwill indicate battery status. 4. A chirping sound from the control box will accompany the red light,indicating that the batte...

Page 4 - Limited Warranty

4 Operating Instructions And Parts Manual Address parts correspondence to: Wayne Water Systems101 Production DriveHarrison, OH 45030 U.S.A. For Replacement Parts, call 1-800-237-0987 Please provide following information: -Model number-Serial number (if any)-Part descriptions and number as shown in p...

Other Wayne Models

All Wayne Other