Wayne 350800-002 - Manual

Wayne 350800-002

Wayne 350800-002 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
Page: / 12

Table of Contents:

  • Page 2 – Maintenance; Operating Instructions And Parts Manual; Troubleshooting Chart
  • Page 3 – Replacement Parts List
  • Page 4 – Limited Warranty; AngelTM’s written instructions.
  • Page 5 – Instructions D’Utilisation et Manuel de Pièces; Fonctionnement
  • Page 6 – Entretien; Guide De Dépannage
  • Page 7 – Liste De Pièces De Rechange; Spécifications
  • Page 8 – Garantie Limitée; QUE SE SOIT EST EXCLUS.
  • Page 9 – Descripción; Manual de instrucciones y lista de repuestos; Instalación
  • Page 10 – Mantenimiento; Guía de diagnóstico de averías
  • Page 11 – Lista de repuestos; Especificaciones
  • Page 12 – Garantía Limitada
Loading the manual

5. Protect electrical cord from sharp

objects, hot surfaces, oils, and chemicals.
Avoid kinking the cord and replace
damaged cords immediately.

IMPORTANT:

Make sure there is adequate

room for the switch to operate.
6. A sump pit cover must be installed to

prevent debris from clogging or
damaging the pump or interfering with
pump.

Operation

Always disconnect the
power source before
attempting to install,
service, relocate or maintain the pump.
Never touch sump pump, pump motor,
water or discharge piping when pump
is connected to electrical power. Never
handle a pump or pump motor with
wet hands or when standing on wet or
damp surface or in water. Fatal
electrical shock could occur.

1. A ground fault circuit interrupter (GFCI)

is required.

Risk of electrical
shock! This pump is

supplied with a grounding conductor
and grounding type attachment plug.
Use a grounded receptacle to reduce
the risk of fatal electrical shock.
Never cut off the round grounding
prong. Cutting the cord or plug will
void the warranty and make the pump
inoperable.

Installation

1. Install pump in a sump pit with minimum

size as shown in Figure 1. Construct sump
pit of tile, concrete, steel or plastic.

2. The unit should be located and rest on

a solid, level foundation. Do not place
pump directly on clay, earth, gravel or
sandy surface. These surfaces contain
small stones, gravel, sand, etc. that may
clog or damage the pump and cause
pump failure.

Flood risk. If

flexible discharge

hose is used, make sure pump is
secured in sump pit to prevent
movement. Failure to secure pump
could allow pump movement and
switch interference and prevent pump
from starting or stopping.

3. Thread check valve (Blue Angel™ offers

Model 66005-BLA1) into pump body
carefully to avoid stripping or cross
threading. Do not use pipe joint sealant.

4. Connect 1-1/2" rigid pipe to rubber boot

on check valve. Reverse boot for 1-1/4"
diameter pipe. Tighten hose clamps.

Support pump and
piping when

assembling and after installation.
Failure to do so could cause piping to
break, pump to fail, etc. which could
result in property damage and/or
personal injury.

Please read and save these instructions. Read carefully before attempting to assemble,
install, operate or maintain the product described. Protect yourself and others by
observing all safety information. Failure to comply with instructions could result in
personal injury and/or property damage! Retain instructions for future reference.

Description

The submersible pump is designed for
indoor home sump applications. The unit is
equipped with an 8-ft long, 3-prong
grounding type power cord. Motor is oil
filled and sealed for cooler running and
designed to operate under water. A float
switch is provided for automatic pump
operation. This pump is not suitable for
aquatic life.

General Safety
Information

Do not use to pump
flammable or explosive
fluids such as gasoline, fuel oil,
kerosene, etc. Do not use in a
flammable and/or explosive
atmosphere. Pump should only be used
to pump clear water. Personal injury
and/or property damage could result.

This pump is not

designed to handle

salt water, brine, laundry discharge or
any other application which may
contain caustic chemicals and/or
foreign materials. Pump damage could
occur if used in these applications and
will void warranty.

All wiring must be
performed by a

qualified electrician. Failure to follow
this warning could result in fatal
electrical shock.

If the basement has water
or moisture on the floor,
do not walk on wet area
until all power is turned off. If the
shutoff box is in the basement, call an
electrician. Remove pump and either
repair or replace. Failure to follow this
warning could result in fatal electrical
shock.

A backup system

should be used.

Blue Angel™ offers Model BSP15 and
BSP25

Operating Instructions and Parts Manual

BRSPT130

350800-002 1/07

Tether

14"

Min. Diameter

Submersible Sump
Pump

14"

Figure 2

Grounded
Outlet

24"

Figure 1

For parts, product & service information

visit

www.blueangelpumps.com

© 2007 Blue Angel™ Pumps

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Maintenance; Operating Instructions And Parts Manual; Troubleshooting Chart

5. While the pump is draining the pit, verify that the discharge piping iscarrying the water to a point several feetaway from the foundation. If pump discharge line is exposed to freezing temperature, the exposed linemust be pitched to drain. Trappedwater will freeze and damage thepump. Maintenance ...

Page 3 - Replacement Parts List

3 BRSPT130 1 Tether Float Switch Kit 60022-001 2 Power Cord Kit 62003-001 3 Impeller 28541-001 4 Impeller Retaining Clip 67106-001 Ref. Parts Numbers No. Description RSP-130 For Replacement Parts, call 1-888-636-6628 Please provide following information: - Model number- Serial number (if any)- Part ...

Page 4 - Limited Warranty; AngelTM’s written instructions.

4 Limited Warranty For one year from the date of purchase, Blue Angel™ will repair or re place, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by Blue Angel™ to be defective in materials or work man ship. Please call Bl...

Other Wayne Models

All Wayne Other