Wagner GS-08 - Manual

Wagner GS-08

Wagner GS-08 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
Page: / 8

Table of Contents:

  • Page 2 – Operating the High Pressure Spray Gun; Locking the Spray Gun; cleaning the Gun; cleaning the Filter
  • Page 3 – Pistolet de pulvérisation à haute pression; Importantes consignes de sécurité
  • Page 4 – Français; utilisation de pistolet de pulvérisation; Verrouillage du pistolet; Nettoyage de pistolet; Nettoyage du filtre
  • Page 5 – Pistola de alta presión; Información Importante sobre Seguridad
  • Page 6 – Español; Operación del pistola de alta presión; Bloquear la pistola; Limpieza la pistola; Limpieza el filtro de la pistola rociadora
  • Page 7 – Parts List • Liste de pièces • Lista de piezas
Loading the manual

© Wagner Spray Tech. All rights reserved.

1

Important Safety Instructions

Read all safety information before operating the

equipment. Save these instructions.

Indicates a hazardous situation which, if not avoided, could result in

death or serious injury.
To reduce the risks of fire or explosion, electrical shock and the

injury to persons, read and understand all instructions included in

this manual. Be familiar with the controls and proper usage of the

equipment.

WARNING: EXPLOSION OR FIRE
Solvent and paint fumes can explode or ignite. Property damage and/

or severe injury can occur.

PREVENTION:

• Do not spray flammable or combustible materials near an open flame,

pilot lights or sources of ignition such as hot objects, cigarettes, motors,

electrical equipment and electrical appliances. Avoid creating sparks from

connecting and disconnecting power cords.

• For units intended for use with only water-based or mineral spirit-type

materials with a minimum flash point of 38ºC (100ºF) — Do not spray or

clean with liquids having a flash point of less than 38ºC (100ºF). Flash point

is the temperature at which a fluid can produce enough vapor to ignite.

• Use extreme caution when using materials with a flashpoint below 100ºF

(38ºC). Refer to your pump manual to determine if these materials can

be sprayed.

• Paint or solvent flowing through the equipment is able to result in static

electricity. Static electricity creates a risk of fire or explosion in the presence

of paint or solvent fumes. All parts of the spray system, including the

pump, hose assembly, spray gun and objects in and around the spray area

shall be properly grounded to protect against static discharge and sparks.

Use only conductive or grounded high-pressure airless paint sprayer hoses

specified by the manufacturer.

• Verify that all containers and collection systems are grounded to prevent

static discharge.

• Connect to a grounded outlet and use grounded extension cords (electric

models only). Do not use a 3 to 2 adapter.

• Do not use a paint or solvent containing halogenated hydrocarbons. Such

as chlorine, bleach mildewcide, methylene chloride and trichloroethane.

They are not compatible with aluminum. Contact the coating supplier

about compatibility of material with aluminum.

• Keep spray area well ventilated. Keep a good supply of fresh air

moving through the area to keep the air within the spray area free from

accumulation of flammable vapors. Keep pump assembly in well ventilated

area. Do not spray pump assembly.

• Do not smoke in the spray area.

• Do not operate light switches, engines, or similar spark producing products

in the spray area.

• Keep area clean and free of paint or solvent containers, rags, and other

flammable materials.

• Know the contents of the paint and solvents being sprayed. Read all

Material Safety Data Sheets (MSDS) and container labels provided with the

paints and solvents. Follow the paint and solvent manufacture’s safety

instructions.

• Place pump at least 25 feet (7.62 meters) from the spray object in a well

ventilated area (add more hose if necessary). Flammable vapors are often

heavier than air. Floor area must be extremely well ventilated. The pump

contains arcing parts that emit sparks and can ignite vapors.

• Plastic can cause static sparks. Never hang plastic to enclose spray area. Do

not use plastic drop cloths when spraying flammable material.

• Fire extinguisher equipment shall be present and working.

WARNING: INjEcTION INjuRy
A high pressure paint stream produced by this equipment can pierce

the skin and underlying tissues, leading to serious injury and possible

amputation. See a physician immediately.

PREVENTION:

• Do not aim the gun at, or spray any person or animal.

• Keep hands and other body parts away from the discharge. For example,

do not try to stop leaks with any part of the body.

• NEVER put your hand in front of the gun. Gloves will not provide

protection against an injection injury.

• ALWAYS keep the tip guard in place while spraying. The tip guard provides

some protection but is mainly a warning device.

• Only use a nozzle tip specified by the manufacturer.

• Use caution when cleaning and changing nozzle tips. In the case where

the nozzle tip clogs while spraying, ALWAYS lock gun trigger, shut pump

off, and release all pressure before servicing, cleaning tip or guard, or

changing tip. Pressure will not be released by turning off the motor.

The PRIME/SPRAY valve or pressure bleed valve must be turned to their

appropriate positions to relieve system pressure. Refer to PRESSURE RELIEF

PROCEDURE described in the pump manual.

• Do not leave the unit energized or under pressure while unattended.

When the unit is not in use, turn off the unit and relieve the pressure in

accordance with the manufacturer’s instructions.

• High-pressure spray is able to inject toxins into the body and cause serious

bodily injury. In the event that injection occurs, seek medical attention

immediately.

• Check hoses and parts for signs of damage, a leak can inject material into

the skin. Inspect hose before each use. Replace any damaged hoses or

parts. Only use Wagner original-high-pressure hoses in order to ensure

functionality, safety and durability.

• This system is capable of producing 3000 PSI / 207 Bar. Only use

replacement parts or accessories that are specified by the manufacturer

and that are rated a minimum of 3000 PSI. This includes spray tips, nozzle

guards, guns, extensions, fittings, and hose.

• Always engage the trigger lock when not spraying. Verify the trigger lock is

functioning properly.

• Verify that all connections are secure before operating the unit.

• Know how to stop the unit and bleed pressure quickly. Be thoroughly

familiar with the controls. Pressure will not be released by turning off the

motor. The PRIME/SPRAY valve or pressure bleed valve must be turned to

their appropriate positions to relieve system pressure. Refer to PRESSURE

RELIEF PROCEDURE described in the pump manual.

• Always remove the spray tip before flushing or cleaning the system.

NOTE TO PHySIcIAN:
Injection into the skin is a traumatic injury which can lead to possible

amputation. It is important to treat the injury as soon as possible. DO

NOT delay treatment to research toxicity. Toxicity is a concern with some

coatings injected directly into the blood stream. consultation with a plastic

surgeon or reconstructive hand surgeon may be advisable.

WARNING: GENERAL
Can cause severe injury or property damage.

PREVENTION:

• Always wear appropriate gloves, eye protection, clothing and a respirator

or mask when painting.

• Do not operate or spray near children. Keep children away from equipment

at all times.

• Do not overreach or stand on an unstable support. Keep effective footing

and balance at all times.

• Stay alert and watch what you are doing.

• Do not operate the unit when fatigued or under the influence of drugs or

alcohol.

• Do not kink or over-bend the hose. Airless hose can develop leaks from

wear, kinking and abuse. A leak can inject material into the skin.

• Do not expose the hose to temperatures or pressures in excess of those

specified by manufacturer.

• Do not use the hose as a strength member to pull or lift the equipment.

• Use lowest possible pressure to flush equipment.

• Follow all appropriate local, state and national codes governing ventilation,

fire prevention and operation.

• The United States Government Safety Standards have been adopted

under the Occupational Safety and Health Act (OSHA). These standards,

particularly part 1910 of the General Standards and part 1926 of the

Construction Standards should be consulted.

• Before each use, check all hoses for cuts, leaks, abrasion or bulging of cover.

Check for damage or movement of couplings. Immediately replace hose

if any of those conditions exist. Never repair a paint hose. Replace with a

conductive high-pressure hose.

• Do not spray outdoors on windy days.

• Always unplug cord from outlet before working on equipment (electric

models only).

Model GS-07 / GS-08

High Pressure Spray Gun

0614 • Form No. 0523594B

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Operating the High Pressure Spray Gun; Locking the Spray Gun; cleaning the Gun; cleaning the Filter

English 2 © Wagner Spray Tech. All rights reserved. English Operating the High Pressure Spray Gun The gun is designed for pressures up to 3000 PSI, 207 bar. POSSIBLE INjEcTION HAZARD - Do not spray without the tip assembly in place. Never trigger the gun unless the tip is in either the spray or the ...

Page 3 - Pistolet de pulvérisation à haute pression; Importantes consignes de sécurité

© Wagner Spray Tech. Tous droits réservés. 3 Modèle GS-07 / GS-08 Pistolet de pulvérisation à haute pression Importantes consignes de sécurité Lire toutes ces consignes avant d’utiliser l’appareil. Garder ces consignes. Indique une situation à risque, laquelle, si elle n’est pas évitée, peut entraîn...

Page 4 - Français; utilisation de pistolet de pulvérisation; Verrouillage du pistolet; Nettoyage de pistolet; Nettoyage du filtre

Français 4 © Wagner Spray Tech. Tous droits réservés. utilisation de pistolet de pulvérisation Le pistolet est conçu pour des pressions jusqu’à 3 000 PSI/207 bar. DANGER D’INjEcTION ÉVENTuEL - Ne pas faire de la pulvérisation sans que le protecteur de la tête de pulvérisation ne soit en place. Ne ja...

Other Wagner Models

All Wagner Other