Viking DEV900 - Manual
Viking DEV900 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – ROOF INSTALLATIONS; REMOVE; Roof Rafter; inside edge; Figure 1; PREPARE THE VENTILATOR; PILOT HOLE; inside edge; WALL STUD; Figure 3
- Page 3 – INSTALL THE VENTILATOR; WALL INSTALLATIONS
- Page 4 – USE AND CARE; CLEANING; INSTALL THE ROUGH-IN PLATE; Run 120 VAC electrical power cable from service; VIKING RANGE CORPORATION
- Page 5 – Dimensions de ventilateur; PLANIFICATION DE LA POSE; TOUS LES TYPES DE POSE; SPÉCIFICATIONS; INSTALLATEUR : Veuillez laisser ce manuel au propriétaire; VEUILLEZ LIRE CES DIRECTIVES ET LES CONSERVER; AVERTISSEMENT
- Page 6 – POSES SUR LES TOITS; PRÉPARATION DU VENTILATEUR; rebord intérieur
- Page 7 – POSE DU VENTILATEUR; POSES SUR LES MURS
- Page 8 – UTILISATION ET ENTRETIEN; NETTOYAGE; Faites cheminer les conduits ronds en acier de 25,4 cm; Branchez le conduit à la plaque de raccordement et
1
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
1. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer or your distributor.
2. Before servicing or cleaning unit, switch power off
at service panel and lock the service disconnect-
ing means to prevent power from being switched
on accidentally. When the service disconnecting
means cannot be locked, securely fasten a promi-
nent warning device, such as a tag, to the service
panel.
3. Installation work and electrical wiring must be
done by a qualified person(s) in accordance with
all applicable codes and standards, including fire-
rated construction codes and standards.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of
fuel burning equipment to prevent backdrafting.
Follow the heating equipment manufacturer's
guideline and safety standards such as those
published by the National Fire Protection Associa-
tion (NFPA), and the American Society for Heat-
ing, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
WARNING
CAUTION
1. For general ventilating use only. Do not use to ex-
haust hazardous or explosive material and vapors.
2. To avoid motor bearing damage and noisy and/or
unbalanced impellers, keep drywall spray, con-
struction dust, etc. off power unit.
3. Please read specification label on product for
further information and requirements.
4. Electrical circuit, including speed control, (if used),
must be rated 6 AMPS minimum.
Blower Dimensions
28.25 x 24.75 x 7.17
PLAN THE INSTALLATION
1. Locate the ventilator so the length of the duct run
and number of elbows needed are kept to a mini-
mum.
2. Where possible, ventilator should be centered
between wall studs or roof rafters.
3. Avoid pipes, wires, or other ductwork that may be
running through the wall.
ALL INSTALLATIONS
MODEL
VOLTS
AMPS
CFM
DUCT SIZE
DEV900
120
5.7
900
10 " DIA.
SPECIFICATIONS
INSTALLER: Leave This Manual With The Homeowner
HOMEOWNER: Use And Care Information On Page 4
5. When cutting or drilling into wall, or ceiling, do not
damage electrical wiring or other hidden utilities.
6. Ducted fans must always be vented to the out-
doors.
7. To reduce risk of fire, use only metal ductwork.
8. This unit must be grounded.
READ AND SAVE THESE INSTRUCTIONS
VIKING MODEL DEV900
EXTERIOR MOUNTED VENTILATOR
FOR USE WITH VIKING VCWH, VICH, DBCV, DICV, DCWH, DCWL, DCWN,
DTWS AND DCIH RANGE HOODS. 30" TO 42" WIDE, 9" TO 18" HIGH.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 11" dia. hole 2 9 ½ " 11" dia. hole 1¼" dia. hole 1 2 7 / 8 " 1 0 ¾ " 2 5 " 7 ¼ " 7 ¼ " 1¼" dia. hole 9 1 / 8 " 9 1 / 8 " W a ll S tu d 1 0 ¾ " 2 4 ¾ " 2 8 ¼ " W a ll Stud 1 2 7 / 8 " W a ll S tu d W a ll Stud REMOVE SIDING REMOVE SID...
3 1. Remove roofing nails from the upper 2/3 of the shingles around the cutout area and carefully lift theshingles to allow the back flashing sheet on theventilator housing to fit under them. 2. Center the ventilator ring in the 11" diameter hole, making sure that the 1-1/4" diameter electri...
4 99043050E F20222 USE AND CARE Disconnect electrical power supply and lock outservice panel before cleaning or servicing this unit. CLEANING Remove cover and carefully vacuum ventilator andinside of housing. Be careful not to bend or otherwisedamage ventilator wheel. MOTOR LUBRICATION The motor is ...